Log:
Évaluations - 2, GPA: 4 ( )

Instructions Poulan, Modèle 545212827

Fabricant : Poulan
Taille : 98.51 kb
Nom Fichier : NOUS2010_545212827.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


verse the plug. If the plug still does not fit, Do not point blower discharge opening in obtain a correct polarized extension cord. the direction of people or pets. A polarized extension cord will require the use of a polarized wall outlet. This plug will FUEL SAFETY (for gas powerheads) fit into the polarized wall outlet only one D Eliminate all sources of sparks or flame (in way. If plug does not fit fully into the wall cluding smoking, open flames, or work that outlet, reverse the plug. If it still does not fit, can cause sparks) in the areas where fuel is contact a qualified electrician to install the mixed, poured, or stored. proper wall outlet. Do not change the equip- D Mix and pour fuel in an outdoor area; store ment plug, extension cord receptacle, or fuel in a cool, dry, well ventilated place; use extension cord plug in any way. an approved, marked container for all fuel D To reduce risk of electrical shock, use ex- purposes. tension cords specifically marked as suit- D Do not smoke while handling fuel or while able for outdoor appliances having electri operating the unit. cal rating not less than the rating of unit. D Make sure the attachment is properly as- Cord must be marked with suffix “W- --A” (in sembled and in good operating condition. Canada “W”). Make sure your extension D Do not fill fuel tank while engine is running. cord is in good condition. Inspect extension D Avoid spilling fuel or oil. Wipe up fuel spills cord before use and replace if damaged. Do before starting engine. not use a damaged cord. Cord insulation D Move at least 10 feet (3 meters) away from must be intact with no cracks or deteriora fuel and fueling site before starting engine. tion. Plug connectors must be undamaged. D Always store gasoline in a container ap- The extension cord used to reach the pow- proved for flammable liquids. er source must be heavy enough to carryELECTRICAL SAFETY (for electric current from the power source the full length powerheads) of the extension cord to the unit. An undersized extension cord will cause a drop in line voltage resulting in loss of power andWARNING: overheating. If in doubt, use the next heavi- Avoid a dangerous environment. To reduce the er gauge. The lower the gauge number, the risk of electrical shock, do not use in rain, in heavier the cord. damp or wet locations, or around swimming D Do not use multiple cords. pools, hot tubs, etc. Do not expose to snow, D Keep the extension cord clear of operator and rain, or water to avoid the possibility of electrical obstacles at all times. shock. Do not use on wet surfaces. Do not han-D Tie cord to cord retainer and connect to redle extension cord plug or unit with wet hands. cessed plug as shown in this manual to pre- Avoid dangerous situations. Do not use in the vent damage to unit and/or extension cord presence of flammable liquids or gases to avoid and to reduce the possibility of the extencreating a fire or explosion and/or causing dam-sion cord disconnecting from the unit during age to unit. Do not abuse cord. Never carry the operation. unit by the extension cord or yank extension S Do not attempt to repair unit. Inspect the insucord to disconnect unit. To unplug, grasp the lation and connectors on the powerhead and plug, not the cord. Do not use cord as a handle, extension cord before each use. If there is close a door on cord, or pull cord around sharp any damage, do not use until damage is re- edges or corners. Turn off all controls before un-paired by your authorized service dealer. plugging. Do not expose cords to heat, oil, or D Do not use the powerhead if the switch water. Do not use with damaged cord or plug. If does not turn the unit on and off properly. unit is not working as it should, has been Have the unit repaired by your authorized dropped, damaged, left outdoors, or dropped service dealer. --3 - - S Avoid unintentional starting of the unit. Never carry unit with your finger on the switch. Be sure the switch is in the OFF position and never touch the switch when connecting extension cord. D Avoid any body contact with any grounded conductor, such as metal fences, or pipes, to avoid the possibility of electric shock. D Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuit or outlet to be used for the powerhead. Receptacles are available having built-in GFCI protection and may be used for this measure of safety. D Stop the motor immediately if you are approached. BLOWER SAFETY WARNING: Never put hands or other objects into blower housing to avoid serious injury from the rotating impeller. WARNING: Inspect the area before using the unit. Remove all debris and hard objects such as rocks, glass, wire, etc., that can ricochet, be thrown, or otherwise cause injury or damage during operation. S Inspect attachment before each use for worn, loose, missing, or damaged parts. Do not use until unit is in proper working order. S Keep outside surfaces free from oil and fuel. S Never start or run...

Ce manuel est également adapté pour les modèles :
Les systèmes de ventilation - 952711609 (98.51 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories