Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions Blue Rhino, Modèle GBC9129M

Fabricant : Blue Rhino
Taille : 4.91 mb
Nom Fichier : a3655516-9b17-41f1-8768-9aa925119939.pdf
Langue d'enseignement: enes
Aller à la télécharger



Facilité d'utilisation


Some jurisdictions do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to everyone. Vendor does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment, and no such representations are binding on Vendor. Blue Rhino Global Sourcing, Inc Winston-Salem, North Carolina 27105 USA 1.800.762.1142 Troubleshooting Problem Possible Cause Prevention/Cure Burner will not light using ignitor Battery needs to be changed. Replace the AA battery. (Follow assembly step for inserting battery. Wires or electrode covered with cooking residue. Clean wire and/or electrode with rubbing alcohol. Electrode and burners are wet. Wipe dry with cloth. Electrode cracked or broken - sparks at crack. Replace electrode. Wire loose or disconnected. Reconnect wire or replace electrode/wire assembly. Wire is shorting (sparking) between ignitor and electrode. Replace ignitor wire/electrode assembly. Bad ignitor. Replace ignitor. Burner will not light with match No gas flow. Check if LP gas tank is empty. If empty, replace or refill. If LP gas tank is not empty, refer to “Sudden drop in gas flow or reduced flame height”. Coupling nut and regulator not fully connected. Turning the coupling nut about one-half to three quarters additional turn until solid stop. Tighten by hand only-do not use tools. Obstruction of gas flow. Clear burner tubes. Check for bent or kinked hose. Disengagement of burner to valve. Reengage burner and valve. Spider webs or insect nest in venturi. Clean venturi. Burner ports clogged or blocked. Clean burner ports. Sudden drop in gas flow or reduced flame height Out of gas. Replace or refill LP gas tank. Excess flow; safety device may have been activated. Turn control knobs to “OFF”. Wait 30 seconds and light grill. If flames are still too low, reset the excessive flow safety device by turning control knobs “OFF” and LP gas tank valve to “CLOSED”. Disconnect regulator. Turn control knobs to “HIGH”. Wait 1 minute. Turn control knobs to “OFF”. Reconnect regulator and leak check connections. Slowly turn LP gas tank valve to “OPEN”. Wait 30 seconds and then light grill per lighting instructions. Irregular flame pattern, flame does not run the full length of burner. Burner ports are clogged or blocked. Clean burner ports. Flame is yellow or orange. New burner may have residual manufacturing oils. Burn grill for 15 minutes with the lid closed Spider webs or insect nest in venturi Clean venturi. Food residue, grease or seasoning salt on burner. Clean burner. Poor alignment of valve to burner venturi. Assure burner venturi is properly engaged with valve. Flame blow out High or gusting winds. Do not use grill in high winds. Low on LP Gas. Replace or refill LP gas tank. Excess flow valve tripped. Refer to “Sudden drop in gas flow or reduced flame height”. Flare-up Grease buildup. Clean grill. Excess fat in meat. Trim fat from meat before grilling. Excessive cooking temperature. Adjust (lower) temperature accordingly. Persistent grease fire. Grease trapped by food buildup around burner system. Turn control knobs to “OFF”. Turn LP gas tank valve to “CLOSED”. Leave lid in closed position and let fire burn out. After grill cools, remove and clean all parts. Flashback (fire in burner tube(s)). Burner and/or burner tubes are blocked. Clean burner and/or burner tubes. Inside of lid is peeling (like paint peeling). The lid is stainless steel, not painted. Baked on grease buildup has turned to carbon and is flaking off. Clean thoroughly. For more assistance please visit us online at or call 1.800.762.1142. MANUAL DEL USUARIO Parrilla de gas propano para exteriores Modelo no. GBC9129M Indice Salvaguardias importantes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pagina 2 Diagrama de explosion y elementos de ferreteria . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Instrucciones de armado . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Instalacion del tanque de gas propano liquido (PL) . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Insertar el tanque de propano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Asegurar el tanque de propano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Conectar el tanque de propano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Instrucciones de operacion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Comprobar si hay fugas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Operacion de los quemadores principales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Operacion...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories