|
Facilité d'utilisation
• One hood located behind the door assembly. • One of the following contemporary floor media kits (sold separately): a. Tumbled River Stone b. Crushed Glass, Obsidian Black c. Crushed Glass, Diamond White d. Crushed Glass, Deep Sea Blue e. White Beach Sand • Optional Contemporary facade kits (sold separately) INTRODUCTION The Millivolt appliances have a millivolt gas control valve with piezo ignition system. If any optional accessories that will require electrical power are to be installed, the electrical power must be provided at the time of appliance installation. The Electronic appliances have an electronic intermittent pilot ignition system. External electrical power is required to operate these units. The battery back-up can be used in case of a power outage. Theseventedgasfireplacesaresealedcombustion, air-circulating gas fireplaces designed for residential applications. Use Only These Approved Vent Components: These fireplaces are designed, tested and listed for operation and installation with, the following (4-1/2" inner and 7-1/2" outer) vent components only: • Secure Vent™ Direct-Vent System Components manufactured by Security Chimneys International, • Secure Flex™ Flexible Vent Components manufactured by Security Chimneys International and • Z-FLEX™ Model GA Venting Systems listed to UL1777 and ULCS635 manufactured by Flexmaster Canada Limited. These approved vent system components are labeled for identification. DO NOT use any other manufacturer’s vent components with these appliances. WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physicalbarrierisrecommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces. LENNOX HEARTH PRODUCTS • MERITLENNOX HEARTH PRODUCTS • MERITSERIES DIRECT-VENT CONTEMPORARY DESIGN GAS FIREPLACES • MODEL MLDVTCD-35 • INSTALLATION INSTRUCTIONS WARNING Improper installation, adjust ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. WARNING Failure to comply with these installationinstructionswillresult in an improperly installed and operating appliance, voiding its warranty. Anychangetothisappli ance and/or its operating controls is dangerous. WARNING Clothing or other flammable material should not be placed on or near the appliance. AVERTISSEMENT On ne devrait pas placer de vetements ni d’autres matieres inflammables sur l’appareil ni a proximite. WARNING Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance. AVERTISSEMENT Tout ecran ou protecteur retire pour permettre l’entretien de l’appareil doit etre remis en place avant de mettre l’appareil en marche. WARNING Improper installation or use of thisappliance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning. Note: Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etcetera. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. Remarque : L’installation et la reparation devrait etre confiees a un technicien qualifie. L’appareil devrait faire l’objet d’une inspection par un technicien professionnel avant d’etre utilise et au moins une fois l’an par la suite. Des nettoyages plus frequents peuvent etre necessaires si les tapis, la literie, et cetera produisent une quantite importante de pous-siere. Il est essentiel que les compartimentsabritantlescommandes, lesbruleurset les conduits de circulation d’air de l’appareil soient tenus propres. Do not use these appliances if any part has been under water. Immediately call a qualified, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water. Nepasutilisercetappareils’ilaeteplonge, meme partiellement, dans l’eau. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du systeme de commande et toute commande qui a ete plongee dans l’eau. Only trim kit(s) supplied by the manufacturer shall be used in the installation of this appliance. Seules les trousses de garniture fournies par le fabricant doivent etre utilisees pour l’installation de cet appareil. These appliances comply with National Safety Standards and are tested and listed by ETL/ Intertek (Report No. 100353019PRT-002) to ANSI Z21.50 (in Canada, CSA-2.22), and C...
Ce manuel est également adapté pour les modèles :Greeley - MLDVTCD-35NM (3.04 mb)