Log:
Évaluations - 3, GPA: 4.7 ( )

Instructions Weil-McLain, Modèle 800062000-Brn-PO Rie BF5

Fabricant : Weil-McLain
Taille : 601.73 kb
Nom Fichier : 711b37f0-5916-436c-bcb6-fbd134669f1e.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


-Line up the holes in the UNIVERSAL MOUNTING FLANGE with the STUDS (3) on the appliance mounting plate and securely bolt the UNIVERSAL MOUNTING FLANGE to the plate. To remove the burner from the boiler, reverse the procedure. E9328 ELECTRICAL CONNECTIONS It is advisable to leave the control box off the sub-base while completing the electrical connection to the burner. 1) Wire access hole (Use BX electrical connector) 2) Earth ground conductor terminal (Green wire) 3) Hot conductor terminal (Black wire) 4) Neutral conductor terminal (White wire) WARNING: The hot (black) wire must be connected to the L terminal and the neutral (white) wire must be connected to the N terminal or the primary safety control will be damaged. Do not connect wither wire to the terminal marked . D7954 Using the appropriate diagram below, make electrical connections to burner. All wiring must be done in accordance with existing electrical codes, both national and local. When all electrical connections have been made, the control box may be put back in place on the sub-base. WARNING: DO NOT activate burner until proper oil line connections have been made, or failure of the pump shaft seal may occur. (3398) 3398 3 GB APPLICATION FIELD WIRING REMOTE SENSING OF SAFETY LOCKOUT The SAFETY SWITCH in the 530SE CONTROL BOX is equipped with a contact allowing remote sensing of burner lockout. The electrical connection is made at terminal 4 (•) on the SUB-BASE. Should lockout occur the 530SE CONTROL BOX will supply a power source of 120Vac to the connection terminal. The maximum allowable current draw on this terminal (4) is 1 Amp. WARNING: If a neutral or ground lead is attached to this terminal, the CONTROL BOX on the burner will be damaged should lockout occur. Earth L2 Ground L1 Oil Valve Capacitor GREEN BLUE BLACK BLACK WHITE BLUE M BROWN AL 1009-1 Burner Fan-Off Timer 6 12 8 N1 11 9 32 7 Control Box 530 SE/C YELLOW BLUE RED GREY L WHITERED BLACK WG R B WHITE RED BROWN Ground FACTORY WIRED SUB BASE LIMIT Switches SAFETY Switches Fuse 15 A WHITEGREENBLACKRED FIELD WIRING 4 AIR PRESSURE SWITCH 10 BLUE BLUE BLUE D8173 (R) (G_) (GREEN) (undefined) (AIRPR SSURE SWITCH) (Control Box: 1) Unchecked (Control Box: 8) Unchecked (Control Box: 11) Unchecked (Control Box: 10) Unchecked (Control Box: 2) Unchecked (YELLOW BLUE) (YELLOW) Motor (3398) 3398 4 GB INSTALLATION/REMOVAL OF DRAWER ASSEMBLY Removal: A) Remove the air pressure switch support (6) from the front shield by the two retaining screws (7) B) Loosen off oil delivery tube nut from pump. C) Loosen SCREW (3), and then unplug CONTROL BOX (1) by carefully pulling it back and then up. D) Remove the AIR TUBE COVER PLATE (5) by loosening the retaining SCREW (4) (Two SCREWS – Model BF5). E) Loosen SCREW (2), and then slide the complete drawer assembly out of the combustion head as shown. F) To insert drawer assembly, reverse the procedure in items A to E above. E9327 ELECTRODE SETTING IMPORTANT: These dimensions must be observed and verified. 5/32” or 4 mm 5/32” to 13/64” or 4 to 5 mm 13/ 64” 5 mm D6003 (undefined) (undefined) NOZZLE PLACEMENT -Remove the NOZZLE ADAPTER (2) from the DRAWER ASSEMBLY by loosening the SCREW (1). -Insert the proper NOZZLE into the NOZZLE ADAPTER and tighten securely (Do not over tighten). -Replace adapter, with nozzle installed, into drawer assembly and secure with screw (1). IMPORTANT: The nozzle and the pump pressure must be in accordance with the burner setup chart at page 9. TURBULATOR SETTING A) Loosen NUT (1), and then turn SCREW (2) until the INDEX MARKER (3) is aligned with the correct index number as per the burner setup chart at page 9. B) Retighten the RETAINING NUT (1). MODEL BF3: Zero and three are scale indicators only. From left to right the first line is 3 and the last line 0. MODEL BF5: Same as above, except scale indicators are 0 and 4. S7459 3 2 1 D7520 (_Row_1) (3398) 3398 5 GB OIL LINE CONNECTIONS This burner is shipped with the oil pump set to operate on a single line system. To operate on a two-line system the by-pass plug must be installed. WARNING Do not operate a single line system with the by-pass plug installed. Operating a single line system with the by-pass plug installed will result in damage to the pump shaft seal. NOTE: (undefined) (undefined) Pump pressure must be set at time of burner start-up. A pressure gauge is attached to the PRESSURE PORT (8) for pressure readings. All pump port threads are British Parallel Thread design. Direct connection of NPT threads to the pump will damage the pump body. Riello manometers and vacuum gauges do not require any adapters, and can be safely connected to the pump ports. An NPT (metric) adapter must be used when connecting other gauge models. SINGLE LINE (GRAVITY FEED SYSTEM) The burner is shipped configured for use in single line applications. No changes to the oil pump are required for use in single line applications. NOTE: If the pump cover (1) is removed for any reason, be sure the O-ring (2), ...

Ce manuel est également adapté pour les modèles :
Greeley - 800060000-Brn-PO Rie BF5 (601.73 kb)
Greeley - 800061000-Brn-PO Rie BF5 (601.73 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories