|
Facilité d'utilisation
2. After grill is completely assembled, make sure natural gas supply valve is “OFF” and then connect natural gas hose to socket. Push sleeve back on socket (Figure B) and insert plug until sleeve snaps forward, locking plug into socket. Be sure to leak test these connections prior to use. Insert cover when hose is disconnected Pipe nipple Quick-disconnect coupling Plug Sleeve Natural gas supply Hose (Figure A) Supply valve (Figure B) Push sleeve back to attach Socket Natural gas supply Hose Supply valve DISCONNECTING YOUR GRILL FROM THE NATURAL GAS SOURCE 1. Turn natural gas supply valve “OFF” 2. To disconnect, push sleeve back and pull plug out of sleeve. • Never use your grill without leak testing all gas connections and hoses. See the section on “Leak Testing” in this manual for proper procedures. • Visually inspect the hose assembly prior to each use for evidence of damage, excess wear or deterioration. If found, replace the assembly before using your grill. Only the manufacturer's supplied replacement should be used. • During assembly or conversion to natural gas, keep the supply hoses free of kinks and/or damage. WARNING WARNING AVOID HARD METAL PIPING • DO NOT use hard metal piping of any kind to connect this converted natural gas grill. Use only natural gas hose specified by the manufacturer. Using hard metal piping or convoluted metal tubing is an unsafe practice. Movement of the grill can cause breakage of metal pipe. LEAK TESTING: To prevent fire or explosion hazard: • DO NOT smoke or permit ignition sources in the area while conducting a leak test. • Perform test OUTDOORS only in a well ventilated area. • Never perform a leak test with a match or open flame. • Never perform a leak test while the grill is in use or while grill is still hot. DANGER WARNING WHEN TO PERFORM A LEAK TEST: • After assembling or converting your natural gas grill and before lighting for the first time, even if purchased fully assembled. • Any time the gas components are replaced. • Any time your grill has been moved. • At least once per year or if your grill has not been used for more than 60 days. CHECKING FOR LEAKS: 1. Create a mixture of 50% water and 50% liquid dishwashing soap. 2. Open the lid. 3. Ensure all control knobs are set to the "OFF" position. 4. Ensure gas hose is tightly connected to gas source. 5. Turn on the fuel supply on at the source. 6. Apply the soap water mixture to the following: Note: Some Grill models will have different connections than illustrated. EDBA Hose connection to gas manifold. Gas supply hose connection to side burner valve assembly. Side burner valve stem cap. (if applicable) Side burner connection to hose. (if applicable) The full length of gas supply hose. CAUTION: Before first use, check gas supply line connection to rotisserie burner ABCDEvalve (under control panel) and gas supply line connection to the orifice (back of grill body). Push in and turn the rotisserie control knob to “HIGH” and hold in the knob when performing gas leak test on rotisserie valve. Allow gas to dissipate when finished. GF Rotisserie orifice connection. (if applicable) Rotisserie supply line connection to rotisserie valve assembly. (if applicable) Note: Rotisserie gas supply line can be gas leak tested by removing the grease tray and applying soap water mixture from under the control panel. Quick disconnect coupler. H HGF 7. Check each place listed (A–H) for growing bubbles which indicates a leak. 8. Turn off gas supply at source. Watch For Bubbles 9. Turn on control knobs to release gas pressure in hose. 10. Turn control knobs to "OFF" position. 11. Tighten any leaking connections. 12. Repeat soapy water test until no leaks are detected. 13. Turn off gas supply at source until you are ready to use your grill. 14. Wash off soapy residue with cold water and towel dry. 15. Wait 5 minutes to allow all gas to evacuate the area before lighting grill. CAUTION: DO NOT use the grill if leaks cannot be stopped. Note: The leak test must be performed in an area that has adequate lighting in order to see if bubbles are developing. WARNING PRE-START CHECK LIST: Property damage, bodily harm, severe burns, and de...
Ce manuel est également adapté pour les modèles :Greeley - 810-8530-S (13.08 mb)
Greeley - 810-7405-S (13.08 mb)
Greeley - 810-8500-S (13.08 mb)
Greeley - 810-8532-S (13.08 mb)