Log:
Évaluations - 4, GPA: 3.8 ( )

Instructions Weber, Modèle 42377

Fabricant : Weber
Taille : 453.72 kb
Nom Fichier : 84908f35-45f5-41a6-a724-12b08d69d687.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


If you do not use a Weber® approved regulator the Warranty on the Summit® Built-In Side Burner will be voided. If you have any questions, contact Customer Service at 1-800-446-1071 2) Connect the corrugated gas line to the side burner Connection. Hard piped gas supply top view Figure 1 Cap (Optional Side Burner) Regulator WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fi tting. Note - All factory-made connections have been thoroughly checked for gas leaks. As a safety precaution however, you should recheck all fittings for leaks before using your Summit® Built-In side burner. Shipping and handling may loosen or damage a gas fitting. You will need: a soap and water solution, and a rag or brush to apply it. Turn on gas supply. Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak. Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks. WARNING: Do not ignite burners when leak checking. Regulator to side burner Hard piped gas supply top view Figure 2 7 GAS INSTRUCTIONS Check: 1) Corrugated gas line-to-Accessory “T” Connection. 2) Main gas Supply to regulator WARNING: If there is a leak a connection(1), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual. Check: When leak checks are complete, turn gas supply OFF at Side Burner Lighting Instructions DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive fl ame-up which can cause serious bodily injury or death. Lighting the side burner. 1) Open the side burner lid. 2) Check that the side burner valve is turned OFF. (Push the knob down and turn clockwise to ensure it is in the off position.). GAS INSTRUCTIONS Check: 1) Corrugated gas line-to-Accessory “T” Connection. 2) Main gas Supply to regulator WARNING: If there is a leak a connection(1), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after retightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your region using the contact information sheet provided with your manual. Check: When leak checks are complete, turn gas supply OFF at Side Burner Lighting Instructions DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive fl ame-up which can cause serious bodily injury or death. Lighting the side burner. 1) Open the side burner lid. 2) Check that the side burner valve is turned OFF. (Push the knob down and turn clockwise to ensure it is in the off position.). the source and rinse connections with water. ................................................................................ 3) Turn the gas supply valve on. 4) Push down and turn the side burner control valve to START/HI. 5) Push igniter button and hold until burner ignites. You will hear the igniter sparking. ...... CAUTION: Side burner flame may be difficult to see on a bright sunny day. WARNING: If the side burner does not light: 1) Turn OFF the side burner control valve. 2) Wait 5 minutes to let the gas clear before you try again or try to light with a match. 8 ............ OPERATING Manually Lighting the Side Burner DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death. 1) Open the side burner lid. 2) Check that the side burner valve is turned OFF. (Push the knob down and turn clockwise to ensure that it is in the off position.). 3) Turn the gas supply valve on. 4) Put match in a match holder and strike match. 5) Push down and turn the side burner control valve to START/HI. 6) Hold match holder and lit match by right side of side burner. Replace Igniter Batteries Parts required: 1 AA alkaline battery per igniter. Unscrew igniter button from top of control panel. Remove igniter button and contact spring. Remove old battery and replace with a new AA alkaline battery. Positive end(1) of battery faces up as shown in illustration. Replace spring contact(2) and screw igniter button(3) back down. ............ OPERATING Manually Lighting the Side Burner DANGER Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up w...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories