Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Weil-McLain, Modèle 800057000-Brn-PO Rie F5

Fabricant : Weil-McLain
Taille : 495.33 kb
Nom Fichier : 8d819962-ee5b-424e-8871-003f76fd24e4.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


-The following pages contain information, descriptions and diagrams for the proper installation and wiring of the burner. Please read carefully before attempting final installation. -This manual is to remain with the final installation designation. It is the installer’s responsibility to ensure that the burner installation and operation instructions mentioned in this manual are followed and operated within local code authority limits. RIELLO 40 CODE MODEL TYPE (Sticky Note comment Reply 3 of 3 dcrivellente 11.09.2008 15:50:03 blank) C8512519 800057000-Brn-PO Rie F5 1.00GPH Vnt-C C8512520 800058000-Brn-PO Rie F5 1.20GPH Vnt-C (Sticky Note comment Reply 2 of 3 dcrivellente 11.09.2008 15:46:33 blank) C8512521 800059000-Brn-PO Rie F5 1.40GPH Vnt-C C6501071(0) GB INSTALLLATION PRECAUTIONS AIR FOR COMBUSTION Do not install burner in room with insufficient air for combustion. Be sure there is an adequate air supply for combustion if the boiler/furnace room is enclosed. It may be necessary to create a window to permit sufficient air to enter the boiler/furnace room. The installer must follow local ordinances in this regard. CANADA It is suggested that the installer follow CSA standard B139. USA It is suggested that the installer follow NFPA manual #31. CHIMNEY Be sure chimney is sufficient to handle the exhaust gases. It is recommended that only the burner be connected to the chimney. Be sure that it is clean and clear of obstructions. OIL FILTER An external oil filter is REQUIRED, even though there is an internal strainer in the pump. The filter should be replaced at least once a year, and the filter container should be thoroughly cleaned prior to installing a new filter cartridge. DRAFT Follow the instructions furnished with the heating appliance. The pressure in the combustion area should be kept as close to zero as possible. The burner will operate with a slight draft or pressure in the chamber. ELECTRICAL CONNECTIONS CANADA All electrical connections should be done in accordance with the C.E.C. Part 1, and all local codes. The system should be grounded. USA All electrical connections should be done in accordance with the National Electrical Code, and all local ordinances. The system should be grounded. CONTROL BURNER OPERATION Check out the burner and explain its operation to the homeowner. Be sure to leave the Owner’s Instruction sheet with the homeowner. FIRE EXTINGUISHER If required by local codes, install an approved fire extinguisher. ELECTRICAL CONNECTIONS In most localities, a number 14 wire should be used inside a metal conduit. The system should be grounded. A service switch should be placed close to the burner on a fireproof wall in an easily accessible location. GB TABLE OF CONTENTS PACKAGE CONTENTS LIST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SERIAL NUMBER IDENTIFICATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 TECHNICAL DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Mounting flange dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 INITIAL SET-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 OIL BURNER COMPONENT IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Burner components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . .3 ASSEMBLY OF AIR TUBE TO BURNER CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 MOUNTING BURNER TO BOILER OR FURNACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 - 5 Method 1-Universal Mounting Flange. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Method 2-Semi-flange Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Method 3-Pedestal Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Ce manuel est également adapté pour les modèles :
Greeley - 800058000-Brn-PO Rie F5 (495.33 kb)
Greeley - 800059000-Brn-PO Rie F5 (495.33 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories