Instructions Beckett, Modèle R7184

Fabricant : Beckett
Taille : 158.89 kb
Nom Fichier : R7184Series5.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


These developments have enabled control manufacturers to put high-performance features into residential primary controls. Since its introduction in 1999, the Beckett R7184 primary control has made advancements and added features to meet the need of a changing industry. This technical bulletin will discuss some of the new benefits and wiring improvements to the Beckett R7184 revision 5 primary control. The operational sequence, interrupted ignition, limited recycle and reset, diagnostic LED and communication port remain consistent on the R7184A, B, P revision 5 as with the previous revision. How to tell the revision level: The Revision numbers 1, 2 and 3 are located on the label designated by the number printed on its side. Revisions 4 and 5 have been relocated to the side of the primary control cover. The number also is printed on its side. BENEFITS • Matching wire colors between components and control will reduce mistakes during wiring. • Quick Connects on the lead wires from the burner components and wire harnesses allow quick component change-out and reduce the number of leads in the wiring box. • Data port connection enables reading control characteristics with Honeywell Diagnostick™, QS7100T tester or OnWatch QuickRead™ 711. • EnviraCOM™ communication terminals have been added for future networking customization for HVAC systems. Data port Series 5 Control: Component color code Igniter Motor Blue Violet Orange Black Red Alarm contacts EnviraCOM™ (3) terminals or T-T (2) terminals New and relocated features WIRING SYSTEM CHANGES Beckett burners have taken advantage of the changes in the R7184 controls to improve the wiring system. Component and power cord wires, now color-coded to match the terminal colors on the control, are terminated with 0.25-inch flag terminals (QCs) to fit the spade connectors (QCs) on the control. During the time required to convert all components and controls to the new wiring system, some adaptations may be required when replacing individual components on the burner. CHANGING COMPONENTS—When changing components, the type of connection that you need to make depends on the way the components (motor, valve, igniter), power cord and control are terminated. Where all the leads / connections are the same, no modifications are required. Where the two ends of a connection are dissimilar, see the options in the following table: If your components are terminated like this: You should use the following: Components Control Connection options Stripped end Wire leads • Wire nuts Flag terminal Spade • QC (Quick Connect) Flag Terminal Wire leads • Cut flag terminal and strip end-Wire nut Stripped end Spade • Add flag terminal to component lead-QC • Cut existing component lead 6-7 in. from flag terminal and strip end-Wire nut (Fig. 1 & 2) Reduced number of leads in wiring box. Fig. 1-Cutting lead from component to be Fig. 2-Using jumper to connect to new replaced to use as jumper component with stripped leads Beckett Service Kits for termination conversion: 51947-Full service kit including a full complement of (6) QC pigtails (BLK, W, O, BLU, V, R), (6) wire nuts and (9) 0.25-inch flag terminals, and this instruction sheet. 51948-Termination kit including (9) 0.25-inch flag terminals, (6) wire nuts, and instruction sheet. If you have any questions regarding controls or the Beckett R7184 primary control by Honeywell, please contact R.W. Beckett at 1-800-645-2876 or visit our web site at R.W. Beckett Corporation • P.O. Box 1289 • Elyria, Ohio 44036 • (800) 645-2876 • (440) 327-1060 • FAX (440) 327-1064 R.W. Beckett Canada Ltd. • Unit 3 - 430 Laird Road • Guelph, Ontario, Canada N1G 3X7 • (800) 665-6972 • FAX (519) 763-5656 RWB 664857R0404 Printed in U.S.A....


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories