Log:
Évaluations - 2, GPA: 4 ( )

Instructions Genie, Modèle QuietLift 2040C

Fabricant : Genie
Taille : 1.36 mb
Nom Fichier : 1b972295-dcbb-4515-a6b5-e1d51c1f000f.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The receiver in the GDO’s powerhead can receive signals at 315 AND 390 MHz. The remote is factory set at 315 MHz. See Figure 2 and 3 on page 11 for frequency selector switch. Switch your remote control frequency when: • Remote does not have adequate range. • Remote works inconsistently with fresh battery installed - LED feedback lights up when pressing button. • Programming your car’s HomeLink® system. To program a HomeLink® device: (This GDO is HomeLink® compatible.) • Use a small flat screwdriver to switch the frequency selector to 390 MHz. • Follow the HomeLink® instructions in your car owner’s manual. • Reset the remote control frequency to 315 MHz for everyday use. Step 3: ADJUSTING THE OPEN AND CLOSE LIMITS WARNING Stay clear of the opener’s belt, door and all other moving parts during this test. CAUTION Be sure the carriage is disengaged from the belt during the initial limit adjustments. The carriage is disengaged when the release lever is pointing down. DO NOT ENGAGE THE CARRIAGE UNTIL INSTRUCTED . CAUTION Set the Open and Close limits carefully. Setting the limits beyond where the door can physically travel could cause damage to the door, the door hardware or opener. A Check that the carriage is disengaged. • Close the garage door if not already closed . • Mark the rail at the center of the carriage (Figure 1). B Manually raise the door to the fully open position. FOR A ONEPIECE DOOR,, OPEN ONLY UNTIL THE DOOR IS JUST SHORT OF LEVEL. • Mark the rail at the center of the carriage (Figure 1). • Manually close the garage door. CENTER OF CARRIAGE WITH DOOR CLOSED Figure 1 Mark the rail C Examine where the carriage stop (Figure 2).. • Using a remote to activate the opener. – Check where the bullet stops at each end of the rail. Figure 2 Examine where the carriage stops NOTE Repeated activation may cause the opener to thermally shut down (the light will flash 4 times). If so, wait 30 minutes for cool down before continuing. D Adjust the open limit (Figure 3A). • Turn the Open Limit Adjustment Screw 1/4 turn at a time toward the up or down to change where the bullet stops. – Use the remote to cycle the opener after each adjustment. – Adjust until the bullet’s leading edge stops at the pencil mark. Figure 3A Adjusting the open limit For Help, call 1-800-35-GENIE or visit E Adjust the close limit (Figure 3B). • Turn the Close Limit Adjustment Screw 1/4 turn at a time toward the up or down to change where the bullet stops. – Use the remote to cycle the opener after each adjustment. – Adjust until the bullet’s leading edge stops at the Figure 3B Adjusting the close limit pencil mark. ADJUSTING THE OPEN AND CLOSE LIMITS CONTINUED Step 4: NOTE Each 1/4 turn of the adjustment screw equals about 5/8" of carriage travel. NOTE During the next adjustment, if the door stops during opening or reverses during closing before reaching the limits, the door force must be adjusted. Change the door force setting as described in the next section then return here to finish setting these limits. WARNING The door will move during the next adjustment. Stay clear of the door and moving parts A Engage the carriage. • Flip the carriage release lever up and lift the door manually until the carriage engages with the bullet. THE FOLLOWING PARAGRAPH IS FOR SECTIONAL DOORS ONLY. B Activate the opener using the remote. • Move the door in the open direction and wait for the door to stop moving (Figure 1). • Check where the door stopped. – Adjust the open limit screw, and repeat cycling the door and making adjustments until it opens fully. Figure 1 Checking the open limit on sectional C Activate the opener using the remote. • Move the door in the open direction and wait for the door to stop moving (Figure 2). • Check where the door stopped. – Adjust the open limit screw, and repeat cycling the door and making adjustments until it opens to the point where the door is just below level. Figure 2 Checking the open limit on one-piece NOTE Setting the limit too high on a one-piece door will cause the opener to “buck” when starting down. D Activate the opener using the remote. • Move the door in the close direction and wait for the door to stop. • Check where the door stopped. – Adjust the close limit screw and repeat cycling the door and making adjustments until it fully closes. NOTE If the door is reversing after contacting the floor, the limit is set too far toward the door and needs to be set back. Step 5: ADJUSTING AND TESTING THE FORCE CONTROLS WARNING Too much force will prevent safe operation of the garage door. Someone could be seriously injured or killed if the door force is set too high. A closing door may not reverse properly and someone could be pinned under it. An opening door might not stop when going up and someone hanging on the door could be pinned between the door and the header. Never increase the force above the minimum required to move the door. Never adjust the force to compensate for a sticking or bind...

Ce manuel est également adapté pour les modèles :
Portail automatique - QuietLift 2040L (1.36 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories