Step 4: Positioning the Motor End of Operator CAUTION: To prevent damage to steel, aluminum, fiberglass or glass panel doors do not rest the opener of the door without using a 2” x 4” at least 12” long. Raise the motor end of the opener and support it so you can open the door to its fully open position. You may need help raising motor end if ladder is not high enough. Open the door and place a 2” x 4” piece of wood along the top section of the garage door. Rest the double rails on the 2” x 4”, as illustrated. Support the top section of the door to prevent sagging. Step 5: Mounting Motor End of Opener Align the center of opener tracks with the center line previously marked on the top section of the garage door to ensure rail will be parallel with the direction of door travel. Use perforated hangers (cut as needed to adjust length) from ceiling or beams to hang opener at motor end (be sure to locate and mount to solid structural beams, as illustrated). Pre-drill with 3/16” drill bit and use 1/4” x 1-1/2” lag screws to ensure a rigid mount. Attach opener to hangers. WARNING: Do not use gear cap bolt or nut for hanger attachment, this may cause sprocket and chain misalignment, resulting in damage or possible injury! Note: Hanging brackets should be at an angle to provide rigid support. If hangers have no angle or if you use long hangers, cross brace the hangers to eliminate the possibility of sway during operation of the opener. 12 Step 6: Mounting Door Bracket WARNING: Fiberglass, aluminum and steel doors must be reinforced to prevent damage to the door. Check with your garage door manufacturer for their recommendations. Reinforce light weight doors, as illustrated. For wood doors, mount door bracket, using two 1/4”-20 x 2” carriage bolts and 1/4” nuts supplied, on center line of door with middle hole in line with top rollers. For metal doors, mount door bracket, using two 1/4”-20 x 1/2” self drilling screws supplied, on center line of door with middle hole in line with top rollers. Step 7: Installing Light Remove diffuser cover by pressing on both sides of the bottom of the lighting cover at the junction of the housing, releasing the locking tabs, and pulling forward. Screw a 60 Watt bulb (60 Watt Maximum) into socket. For maximum bulb life, “rough service” bulbs are recommended. Align top and bottom tabs on cover to Motor Power Head Unit and push straight on until cover locks into place. Note: light turns on automatically when door is activated and a 4 minute time delay circuit automatically turns light off, allowing ample time to enter the house. A fully open door with light blinking indicates an obstruction or problems with external safety sensors during close travel. See trouble shooting section for further details. Step 8: Installing Wired Wall Station (if included) WARNING: Install all wall controls out of the reach of children and in a location where the door can be seen before activating. Do not mount wall controls near or next to garage door. Wired Wall Station: Wire the garage door opener wall station using bell wire (low voltage electrical wire) connected to COM and P.B. on vertical screw terminal strips, as illustrated. Locate push button adjacent to service entrance door at a minimum height of 5 ft., and at least 5 ft. away from garage door (see illustration in Step 10). Fasten the wall station in a safe location with the (2) Phillips head screws, making sure not to over tighten. Pilot drill mounting holes using a 3/32" bit. Additional wired wall stations may also be installed in accordance with these instructions. CAUTION: Over tightening the screws could deform plastic. 13 Step 9: Installing Deluxe Wireless Wall Station (if included) WARNING: Install all wall controls out of the reach of children and in a location where the door can be seen before activating. Do not mount push buttons near or next to garage door. Locate a convenient place to mount wall station. To keep wall station out of the reach of children, measure at least five feet up from the floor and secure wall station base into wood wall framing using (2) Phillips head screws. Pilot drill mounting holes using a 3/32" bit. Use 2 of 3 holes that best align with wood framing. CAUTION: Over tightening the screws could deform plastic base and interfere with circuit board snaps. NOTE: Insert bottom of circuit board behind bottom snap of wall station base. Pivot circuit board up until board snaps into place. For best results, press on circuit board between battery terminals. Insert battery onto circuit board being careful to match (+) positive battery marking with (+) circuit board marking. Align wall station cover/button assembly with base. Press cover assembly over base until cover snaps into place. A uniform seam between the cover and base indicates a proper installation. Step 10: Install Entrapment Warning Label IMPORTANT: Install Entrapment Warning Label next to wall station in a prominent location Install Entrapment Warning Label next...

Ce manuel est également adapté pour les modèles :
Portail automatique - 3014 (1.07 mb)
Portail automatique - 3018DLX (1.07 mb)
Portail automatique - 3514 (1.07 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories