Facilité d'utilisation


GRANT ACCESS0-9, A-Z SCROLL BLOCK USERDELETE USERENTERADD USERDEVICE SETUP RELAY OUTPUTN.O. contacts SERIAL PORT VOLTSELECT ACRx 2MODEL 1025LM KEEP TERMINALS COVEREDHAZARDOUS VOLTAGES! 24VAC 12/24VOLTSAC/DC EXT. GRANTSWITCH exit TM ACRx 2 Model 1025 OWNERS MANUAL WARNING WARNINGWARNING Disconnect power to the garage door or gate opener before installing the receiver. Children operating or playing with a garage door or gate opener can injure themselves and others. The garage door or gate could close and cause serious injury or death.Do not allow children to operate the push buttons or the remote control transmitters. Install the receiver (and any additional push buttons) out of the reach of children and away from all moving parts of the door or gate and its hardware, but where the garage door or gate is visible. A moving garage door or gate could injure someone under it. Activate the opener only when the door or gate is properly adjusted, you can see it clearly, and there are no obstructions to door or gate travel. WARNING Install the control station and receiver where the door or gate is visible, but away from the door or gate and its hardware. When a receiver is used to activate a commercial door opener, a reversing edge MUST be installed on the bottom of the door. Failure to install a reversing edge under these circumstances may result in serious injury or death to persons trapped beneath the door. FEATURES Code Memory 1025 users with unique radio codes (any combination of 60 series remote controls, 80 series remote controls, 90 series “SECURITY+” remote controls, 66LM keypad, 67LM “SECURITY+” keypad, 466LM commercial keypad, or 99LM keypad remote control codes). Each radio code can have a 5 digit alphanumeric user name assigned to it. Input/Output Connections Terminal block inside case. Two screws each for power, relay output, and command. Power Supply 24 V AC/DC or 12 V DC. Output Control Circuit Relay switching controlled by radio transmitters, or GRANT ACCESS button on control panel, or external push-button. Output Control Rating Case Display Time Clock Relay Switches Up to 3 Amps at 37 VAC max. The ACRx 2 is mounted in an 8" x 10" x 3" metal box, with an integrated hinged lid. All electrical connections can be made through a conduit hole; a type-F connector is available externally for antenna mounting. Keylock provided for securing panel against undesired entry. 16 Character non-backlit, LCD display Time and date are maintained by a real time clock with battery backup. Expected battery life is 10 years. RS-232 Interface An RS-232 interface is provided. This interface is 1200-9600 Baud, 8 bits, no parity, 1 stop bit. This allows use of a computer or printer to record access transactions. This interface can also be used to back up code memory to a computer with the use of Microsoft Windows-compatible software available from Lift-Master. INTRODUCTION The ACRx 2 is a radio receiver which controls a gate or door opener. It can recognize as many as 1,000 different transmitters. It assigns a unique identification code to the user of each transmitter, and can produce a record of when each one is used to gain access. The ACRx 2 can be easily programmed by any authorized person to add new users, remove users, suspend users temporarily, or open the gate or door by pushing one button. It can be connected to a computer for additional control and recordkeeping functions. Once the ACRx 2 is installed, it may be programmed by the installer or by the custodian of the gate. The same procedures are used to make changes at a later time. INSTALLATION Mechanical and electrical installation must be performed by qualified, professional service personnel. Knowledge of electrical codes may be necessary when wiring AC power and certain door actuators. If in doubt, consult with Lift-Master commercial product service at 1-800-588-2806. ACRX & ANTENNA MOUNTING INSTRUCTIONS Mounting the Box Choose a location for the ACRx 2 1025 control box which is: • Protected from tampering • As close to the approaching vehicles as possible for best reception. • Protected from moisture. • Suitable for permanent attachment by mounting screws. • Accessible to necessary wiring. Hold the ACRx 2 control box in its intended mounting location. Make sure the cover opens freely, with the display and controls at a comfortable height and angle for viewing and use. Use the holes in the ACRx 2 box for marking and drilling attachment holes. Antenna Placement For best range, placement of the antenna is crucial. Follow these guidelines for best results. •Make sure there is no interfering signal an the same channel as the ACRx 2. You can monitor channel activity with the Liftmaster M-18 Test Set. On-channel interference is not only due to transmitters, but can also be caused by computing devices, security systems, and other nearby electronic devices. Power invertors and battery chargers are known sources of interference. • The ACRx 2 antenna system can be config...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories