Log:
Évaluations - 3, GPA: 4.7 ( )

Instructions Kenwood, Modèle KAC-X11D

Fabricant : Kenwood
Taille : 1.06 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


3. Install the wire Loosen the screw using the supplied hexagon wrench. Insert the conductor of the wire in the terminal hole, and then tighten the screw. 10 - 13 mm (3/8" - 1/2") English ¦ Multi Amplifier with Remote cable connection ¦ Remote cable connection CAUTION • Before connecting the remote controller cables, always turn the Bass boost level knob all the way to the left. You can control the Bass boost level of the second and subsequent Slave amplifiers simultaneously from the Master amplifier. The volume level of each amplifier is determined by the setting of the Master amplifier (INPUT SENSITIVITY, boost level of the remote controller). Setting the Master amplifier 1. Adjust the INPUT SENSIVITY to the output of the center unit to be connected. 2. Set the LPF frequency and ISF. 3. Turn the LINE OUT FILTER switch ON. Setting the Slave amplifier 1. Turn the LINE OUT FILTER switch OFF. 2. Adjust the INPUT SENSIVITY. • To adjust the Slave amplifier to the same volume as the Master amplifier, adjust the INPUT SENSIVITY to 0.2 V (max.). CAUTION • Before connecting the remote controller cables, always turn the Bass boost level knob all the way to the left. * Commercially available parts Remote cable (6.0 m : 19.7 ft) Remote controller P.CON SPEAKER OUTPUT REMOTE FUSE [30Ax3] BATT. GND LINE IN LINE OUT L R P.CON SPEAKER OUTPUT REMOTE BATT. GND LINE IN LINE OUT L R P.CON SPEAKER OUTPUT REMOTE BATT. GND LINE IN LINE OUT L R P.CON SPEAKER OUTPUT REMOTE BATT. GND LINE IN LINE OUT L R FUSE [30Ax3] FUSE [30Ax3] FUSE [30Ax3] INPUT SENSITIVITY[V] 0.2 [MAX] 0.3 0.5 1 2 3 4 [MIN] 5 LINE OUT FILTER ON OFF INPUT SENSITIVITY[V] 0.2 [MAX] 0.3 0.5 1 2 3 4 [MIN] 5 LINE OUT FILTER ON OFF INPUT SENSITIVITY[V] 0.2 [MAX] 0.3 0.5 1 2 3 4 [MIN] 5 LINE OUT FILTER ON OFF Remote cable Remote controller CENTER UNIT (CD receiver, etc.) Master amplifier Slave amplifier Slave amplifier Power control wire* Extension wire* RCA cable* RCA cable* Use the attached Hexagon Wrench. Hexagon Wrench (Small) English P.CON SPEAKER OUTPUT REMOTE FUSE [30Ax3] BATT. GND LINE IN LINE OUT L R THERMAL MANAGEMENT PROTECTION INPUT SENSITIVITY[V] ISF FREQUENCY[Hz] LPF FREQUENCY[Hz] 0.2 [MAX] 0.3 0.5 200 LINE OUT FILTER ON OFF 150 100 70 35 15 40 20 25 30 50 1 2 3 4 [MIN] 5 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. Controls Remote controller 1 Fuse (30 A . 3) NOTE If you can’t find the specified capacity fuse at your store etc., consult your Kenwood dealer. 2 Battery terminal 3 Power control terminal Controls the unit ON/OFF. NOTE Controls the unit power. Be sure to connect it with all the systems. 4 Ground terminal 5 Speaker output terminals As this unit accepts speakers with a minimum impedance of 1 ohm, connect speakers with 1-ohm or higher impedance to these terminals. 6 REMOTE terminal Connects the Remote cable. NOTE Use the Remote cable of the accessory. 7 LINE IN terminal 8 LINE OUT terminal The audio signal set with the LINE OUT FILTER switch will be output. 9 BOOST LEVEL (Bass boost level) control Sets the level by which the low frequency range should be boosted. 0 Power indicator - FREQUENCY (Bass boost frequency) control Sets the center frequency around which the low frequency range should be boosted. = THERMAL MANAGEMENT indicator Lights this indicator when the internal temperature is high. ~ PROTECTION indicator Lights this indicator when the protection function is activated. (See page 2) ! Power indicator When the power is turned on, the Power indicator lights. @ LPF(Low-Pass Filter) FREQUENCY control This control adjusts the frequency band output from this unit. # ISF (infrasonic filter) control Ultralow frequencies that cannot be reproduced even by a subwoofer speaker do not become sound but become unnecessary oscillations, which affect the sound by causing distortion, etc. Setting this control cuts the frequencies below the respective frequency. This improves the reproduction performance of the speakers by eliminating unnecessary oscillations which will not become sound. $ INPUT SENSITIVITY control Set this control according to the pre-output level of the center unit connected with this unit. NOTE For the pre-output level, refer to the in the instruction manual of the center unit. % LINE OUT FILTER switch Changing over the audio signal output to the LINE OUT terminal. ON position: The audio signal adjusted when setting LPF, INPUT SENSIVITY control and Bass boost (optional accessory) is output to the LINE OUT terminal. OFF position: The audio signal input from the LINE IN terminal is output to the LINE OUT terminal (through output). CAUTION The volume of the audio output to the LINE OUT terminal is different in ON and OFF position. Remember this when changing the LINE OUT FILTER switch from ON to OFF. NOTE The control panel locates under the front side cover. Remove the cover to access to its controls for adjustment. (See page 3) Troubleshooting Guide What might appear to be a malfunction in your unit may just be...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories