Log:
Évaluations - 2, GPA: 3 ( )

Instructions Simer Pumps, Modèle 2105

Fabricant : Simer Pumps
Taille : 185.99 kb
Nom Fichier : 98c2ac57-8226-e9d4-ddf7-fe3c69f8239d.pdf
Langue d'enseignement: enesfr
Aller à la télécharger



Facilité d'utilisation


Pages 2-4 © 2003 MOD. 2105 Installation/Fonctionnement/Pieces Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien, Composer le 1 (800) 468-7867 Francais ................... Pages 5-7 Instalacion/Operacion/Piezas Para mayor informacion sobre el funcionamiento, instalacion o mantenimiento de la bomba: Llame al 1-800-468-7867 Espanol .................Paginas 8-10 SIM545 (Rev. 1/3/07) Safety / Operation ATTENTION: Read carefully before attempting to install, operate or service your pump. Protect yourself and others by observing all safety information and additional instructions included with this equipment. Failure to comply with instructions could result in personal injury and/or property damage! Retain for future reference. DESCRIPTION This submersible pump is intended for water removal from swimming pool covers. Unit is constructed of hi-impact corrosion resistant plastic. Screened inlet prevents large solids from entering pump. SPECIFICATIONS Power supply required........................115V, 60 HZ. Motor ..........................................................16 Watt Motor duty.............................................Continuous Thermal Protector ....................................Automatic Liquid Temp. Range......................Max. 77°F (25°C) Operation Position..................................Horizontal Circuit Requirement (min.) ..........................10 Amp Dimensions (Overall)................6-3/8" x 4-7/8” x 3” Power Cord Set .................................Vinyl, 3-prong Discharge.....Horizontal Male Garden Hose Thread PERFORMANCE GPH IN TOTAL FEET 3' 5' 7' 2105 300 170 0 NOTICE: This unit is not designed for applications involving salt water or brine! GENERAL SAFETY INFORMATION 1. Know the pump application, limitations, and potential hazards. Do not use in explosive atmospheres. Pump water only with this pump. Failure to follow this warning can result in personal injury and/or property damage. 2. Make certain that the power source conforms to the requirements of your equipment. 3. Disconnect power before servicing. 4. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage. 5. Check hoses for weak or worn condition before each use, making certain that all connections are secure. 6. Periodically inspect pump and system components. Perform routine maintenance as required (See MAINTENANCE Section). 7. Provide a means of pressure relief on pumps whose discharge line can be shut-off or obstructed. 8. Personal Safety: a. Wear safety glasses at all times when working with pumps. b. Keep work area clean, uncluttered and properly lighted – replace all unused tools and equipment. c. Keep visitors at a safe distance from the work area. d. Make workshop child-proof – with padlocks, master switches, and by removing starter keys. 9. This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3conductor cord and 3-prong, grounding-type plug. To reduce the risk of electric shock, be certain that it is connected to a properly grounded, Ground Fault Circuit Interrupter (GFCI) protected, grounding-type receptacle. Do not lift pump by the power cord; always lift it by the handle. Where a 2-prong wall receptacle is encountered, it must be replaced with a properly grounded, GFCI protected, 3-prong receptacle installed in accordance with all applicable codes and ordinances. 10. Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Replace or repair damaged or worn cords immediately. 11. Do not touch an operating motor. Modern motors can operate at high temperatures. 12. Power Supply: Pump is designed for 115V., 60 HZ. operation and requires a circuit of 10 amperes or more capacity. It is supplied with a 3-wire cord set with grounding-type plug for use in a 3-wire, grounded outlet. To reduce risk of electrical shock, plug pump into a Ground Fault Circuit Interrupter (GFCI). Consult a local electrician for availability and installation. For safety, circuit should always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway, or ground wire system. Do not cut off the round grounding prong. OPERATION Risk of electric shock. Do not han dle a pump or pump motor with wet hands or when standing on wet or damp surface, or in water. 1. Hand tighten 90-degree garden hose discharge adapter into top of pump. 2. Thread garden hose onto adapter hand tight. Then turn one quarter turn tighter with pliers to seal. Make sure the washer is in the end of the garden hose. 3. Straighten out the garden hose as much as possible. For parts or assistance, call Simer Customer Service at 1-800-468-7867 Maintenance / Repair Parts 4. Use the hose, not the power cord, to position the pump on the pool cover and to retrieve the pump when finished. Make sure that the pump s...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories