Log:
Évaluations - 3, GPA: 5 ( )

Instructions Emerson, Modèle HHB MDP500

Fabricant : Emerson
Taille : 659.15 kb
Nom Fichier : HHB_PortaDisc_man.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


To allow recording, the record protection tag on the disc must be in the correct position. RECORDING FROM MONO INTERNAL MIC 16 17 • RECORD Start recording • PAUSE, RECORD Record pause followed by PAUSE Start recording 4. Adjust the recording levels so that the peak level meters do not go beyond 0dB (marked ‘OVR’ in the top right of the diagram below). If the recording level goes above 0dB, distortion to the recorded material may occur. 5. Press the STOP button to stop recording. Or press the PAUSE button to pause recording. If you press the PAUSE button once again in record pause mode, the PORTADISC will start recording again. MONO RECORDING You can double the recording time on an MD disc by using the mono recording mode. 1. Recall ‘REC MODE ?’ by pressing the SYSTEM button once. 2. Press F1 to choose ‘MONO’. Then press F2 to confirm and F3 to exit. NOTE – The left and right channels will be added and recorded as a mono signal. ONE-TOUCH SETUP Use the SETUP button to quickly configure the PORTADISC for mic, line or digital recordings. 1. Press the SETUP button once to recall ‘OPEN SETUP’ mode. 2. The following setup options are available by scrolling through F1 from the ‘OPEN SETUP?’ menu page. Press F2 to select. SETUP PORTADISC settings USER1 - USER5 5 user-defined settings MIC REC Microphone recording setup LINE REC Line recording setup DIGI REC Digital recording setup You can save your input and system settings (which were made by using the INPUT and SYSTEM buttons) into 5 user memories and then easily recall them by opening the user memories. HOW TO SAVE 5 user memories are available, named ‘USER 1’ to ‘USER 5’. 1. Make your record mode setting using the INPUT button and the SYSTEM button. 2. Press the SETUP button until ‘SAVE SETUP’ is displayed. 3. Press F1 to choose the user memory from USER 1-5. Then press F2 to save. HOW TO OPEN You can open your pre-set record mode, which you saved in the user memories from USER 1-5. 1. Press the SETUP button until ‘OPEN SETUP’ is recalled. 2. Press F1 to choose the user memory from USER 1-5. Then press F2 to open. 6 SECONDS PRE-RECORDING This function enables you to record 6 seconds of audio from the internal memory buffer prior to pressing RECORD. This is a useful function for minimising the chance of missing the beginning of a take. 1. Press the SYSTEM button until ‘PRE-RECORD?’ mode is recalled. 2. Press F1 until ‘YES’ is displayed. Then press F2 to set-up. 3. Enter record pause mode by pressing PAUSE before sliding the RECORD button. CAUTION – For the pre-record mode to work, you need to wait at least 6 seconds after preparing the record pause mode in order to pre-load the buffer. The PORTADISC will not record the full 6 seconds of audio otherwise. 4. Press PAUSE to start recording. The PORTADISC will record the audio, including 6 seconds of audio prior to the start of the recording. REC MODE M O N O SET EXIT SAVE SETUP USER1 SAVE EXIT OPEN SETUP USER1 OPEN EXIT OPEN SETUP MIC REC OPEN EXIT TIME = 0 SECONDS TIME +6 SECONDS ACTUAL RECORDING BEGINS HERE RECORD BUTTON IS PRESSED SETUP MENU USEFUL RECORDING FUNCTIONS PRE-RECORD? YES SET EXIT RECORDING cont. PORT ADISC MDP500 MiniDisc Recor der 5. Press the PAUSE button to enter record pause 4. s Press PAUSE, then select the track that you want to mode. Or press STOP to stop recording. record over using the AMS y y and s buttons. s s INPUT MONITOR FUNCTION You can monitor the incoming audio signal even when you are not recording (the input is always monitored in record pause mode). 1. Eject the MD disc by pressing the OPEN button. 2. Make your record mode setting using the INPUT and SYSTEM buttons. 3. Slide the RECORD button to enter the monitor mode. 4. The input audio signal will appear on the display meter and on both the analog and digital outputs, NOTE – If no track is selected, recording will begin automatically over track 1. 5. Slide the RECORD switch to the right to enter record pause mode. ‘Overwrite!’ will be briefly displayed. 6. Press PAUSE to begin recording. ‘Overwrite!’ will be briefly shown again. If the new track is shorter than the track which is being overwritten, the remaining part of the old track will become the next track on the disc: BEFORE OVERWRITING: whichever analog or digital input source you choose. 5. Press the STOP button to cancel the monitor mode. PEAK HOLD METER TRACK 1 TRACK 2 AFTER OVERWRITING: TRACK 1 TRACK 2 TRACK 3 (OLD TRACK 2) NEW TRACK 2 The level bar meter display shows the audio level with peak hold functions. It can be set as follows: If the new track is longer than the track which is being overwritten, the next track will also be recorded over: 1. Press SETUP until the ‘PEAK HOLD METER’ setup mode is recalled: BEFORE OVERWRITING: PEAKHOLDMETER ? OFF SET EXIT 2. Press F1 to choose the setting you want from ‘OFF’, ‘2SECOND’, and ‘ON’. PEAK HOLD METER mode Peak hold setting TRACK 1 TRACK 2 TRACK 3 AFTER OVERWRITING: TRACK 1 TRACK 2 END OF TRACK 3 NEW TRACK 2 OFF Peaks n...

Ce manuel est également adapté pour les modèles :
CD-joueurs - HHB MDP500 (659.15 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories