In addition, the stopwatch is water resistant. Therefore, it is suitable for aquatic sports or use in rainy weather. • STOPWATCH The stopwatch can measure up to 10 hours in 1/100 seconds. • SPLIT TIME/LAP TIME MEASUREMENT Up to 100 split times and lap times can be measured. 2 • LARGE-SIZED THREE-ROW DISPLAY PANEL Total elapsed time, split time and lap time are displayed at the same time in separate rows, and they can be measured successively without releasing split or lap time measurement. • MEMORY FUNCTION Up to 100 measurements can be stored in memory, and they can be recalled after the measurement is over. • TIME/CALENDAR DISPLAY Year, month, date, hour, minutes, and seconds can be displayed while the stopwatch is not in use. • BATTERY LIFE INDICATOR Lithium battery CR2032 or equivalent is used. • ACCUSPLIT “X” CASE Exclusive professional case with no-fail buttons. 3 There are four buttons as indicated in the illustration. TIME/CALENDAR display STOPWATCH display 4 STROKE/FREQUENCY MEASURING MODE STROKE/FREQUENCY MEASURING display B C A D 5 TIME/CALENDAR SETTING 1. Press “D” to show the time/calendar display. The time/calendar display mark will appear. 2. S1 – Press and hold “B” for 2 seconds until seconds display begins fl ashing. TIME/CALENDAR display mark A C B D Year Month and date Seconds Minutes Hour ACCUSPLIT products use a common setting procedure known as S1-S2-S3-S4. S1 (2 sec) - Enter set function OR S1 (4 sec) - Enter set function & clear the current settings S2 – Select fi eld to be set (selected fi eld will fl ash) S3 – Set fi eld to desired settings S4 – Exit setting function 6 7 STOPWATCH Press “D” in the TIME/CALENDAR display to show the STOPWATCH display. The STOPWATCH display mark will appear. The STOPWATCH can measure up to 10 hours in hours, minutes, seconds and 1/100 seconds. • Before using the stopwatch be sure to reset the digits to “0:00:00.00”. When the stopwatch is stopped, press ”B” to reset. When the stopwatch is counting, press “A” to stop the measurement and then press “B”. A C B STOPWATCH display mark D Split time Lap time Total time (accumulated elapsed time) Split/lap number 3. S2 – Press “B” repeatedly to select the digits (fl ashing) to be adjusted. With each press of “B,” the digits to be adjusted change over in the following order. 4. S3 – Press “A” to set the fl ashing digits or reset the seconds to “00”. • The digits move quickly if “A” is kept pressed. • When the seconds digits count any number from ”30” to “59” and “A” is pressed, one minute is added and the second digits are reset to “00”. 5. S4 – After all the adjustments are completed, press “A” repeatedly until watch exits set mode and returns to the TIME/CALENDAR display. Notes: 1. Hour digits are displayed in the 24-hour indication. 2. Year digits can be set from 1988 to 2027. The calendar adjusts automatically for odd and even months including February of leap years. seconds minutes hour year month date Note: The watch exits set mode automatically after setting date. A A B • “Split time” refers to an elapsed time required to cover a distance from the start to a given point. • “Lap time” refers to an elapsed time required to cover a given section of the whole distance. Lap time Split time Start 1. STANDARD MEASUREMENT Hour Seconds Minutes 1/100 seconds START STOP RESET 8 2. ACCUMULATED ELAPSED TIME MEASUREMENT 9 START STOP RESTART RESET STOP Restart and stop of the stopwatch can be repeated by pressing “A”. B A A A 10 3. SPLIT TIME/LAP TIME MEASUREMENT Note: When the number of stored measurements exceeds 90, fl ashing “FULL” appears, and when it exceeds 100, a warning sound starts beeping. B A B A B B START SPLIT-LAP 1 SPLIT-LAP 2 RESET STOP SPLIT-LAP 8 The split/lap time can be measured repeated by pressing “B”. Split/lap number Split time Lap time Accumulated elapsed time Finish time 11 The stopwatch can store up to 100 split times, 100 lap times and total elapsed time. They are automatically entered into the memory. • With each press of “C”, the time stored is recalled. The time can be recalled successively by keeping the button pressed. • To stop the recall of the stored data, press “A”, “B”, or “D”. The measurements when the stopwatch was stopped will be shown. Then, press “B” to reset the digits to “00”. 4. HOW TO USE THE MEMORY FUNCTION B C C A C C “RECALL” more Reset to “00” Finish time 12 • The time stored in the memory can be recalled even while the stopwatch is measuring. Notes: 1. Even if the digits are reset to “00”, stored times are not erased and can be recalled by pressing “C” unless new measurement is started. 2. If the stopwatch is left untouched with the recalled times shown, the display will automatically return the STOPWATCH display in 1 to 20 minutes. • To measure the lap time and split time while the stored data are being recalled operate the buttons as follows. Press “B” to measure new lap time and split time. Press “A” to stop the measurement. Press “D” to return to the measurement m...