Log:
Évaluations - 4, GPA: 3.8 ( )

Instructions Vitek, Modèle VT-6405

Fabricant : Vitek
Taille : 1.21 mb
Nom Fichier : Vitek-VT-6405-Pdf-Rus.Pdf
Langue d'enseignement: ruukentr
Aller à la télécharger



Facilité d'utilisation


With every pressing of the MODE button switching between hours and seconds, time and date, zone time and weekday, zone time and seconds appears. 1. To set the current time press and hold the MODE button during 2 seconds, the setting language will be flashing on the display. Use the +/- buttons to select the desired language: English (EN), German (GE), French (FR), Italian (IT), Spanish (SP), and Dutch (DU). 2. Press the MODE button to confirm. The year will be flashing on the display. Use the +/- buttons to set the desired value and press the MODE button to confirm. 3. Repeat this procedure to set month, date, date-month format, time format 12/24 hours, hours and minutes. ZONE TIME SETTING 1. Press the MODE button to enter the zone time mode. 2. Press the MODE button during 2 seconds, figures will be flashing on the display, meaning the shift of the zone time. 3. Use the +/- buttons to set the desired value and press the MODE button. SETTING ALARM ACTUATION TIME 1. Press the AL1 or AL2 button once to display the alarm actuation time. If the 9 6405IM.indd 9 12.11.2008 11:21:13 English alarm is switched off, the “OFF” symbol will be displayed. 2. Press the alarm AL1 button during 2 seconds, hours will be flashing. Use the +/- buttons to set the desired value. 3. Hold the AL2 button, the symbols will start flashing. Use the +/- buttons to set the desired value. 4. Press the AL1 or AL2 to cancel the setup mode. 5. To switch off the alarm, press the AL1 or AL2 and the “-“button. REPEAT OF ALARM SIGNAL You can switch of the alarm signal for 8 minutes by pressing the SNOOZE button. If you do not switch off the alarm during two minutes, it will switch automatically to the alarm repeat mode. Maximal quantity of repeats of the signal- 3 times SPECIFICATIONS Temperature measuring Base unit from -5 till +50°C (from +23 till +122°F) Remote sensor from -15 till +60,0°C (from 5 till +140°F) Temperature measuring precision 0,1°C/0,2°F Relative humidity measuring Base unit from 25% till 90% at 25°C (77 °F) Remote sensor from 25% till 90% Relative humidity measuring precision 1% Data transfer frequency 433 MHz Quantity of the sensors Max.3 Operation radius Max. 30 m Power supply Base unit Net adapter 7,5 V DC, 2 batteries “AA”, 1.5 V Remote sensor 2 battereis “AA” Weight Base unit 289 g (without batteries) Remote unit 70 g (without batteries) Dimensions Base unit 90x218,9x32 mm Remote sensor 56x107x24 mm 10 5IM.indd 10 12.11.2008 11:21:13 English Delivery set Base unit - 1 pc. Remote sensor - 1 pc. Net adapter - 1 pc. ATTENTION! - Due to restriction in the printing process, the display in this instruction can differ from the actual display. - The manufacturer reserves the right to change the specifications of the unit without preliminary notice. Service life of the unit is 3 years. The manufacturer reserves the right to change design and specifications of the unit without preliminary notice. Recycling of electronic and electrical appliances X(Used in the EU countries and other countries in Europe with selective sorting system) _ This product is marked by the symbol of the selective sorting, relating to the electrical and electronic component scrap. That means that the product must be taken by a selective system of collection in order to reduce any environmental impact. The electronic products not having been the subject of a selective sorting are potentially dangerous for the environment and human health because of the potential presence of dangerous substances. For details apply to the service dealing with recycling or to the shop where you bought the product. Guarantee Details regarding guarantee conditions can be obtained from the dealer from whom the appliance was purchased. The bill of sale or receipt must be produced when making any claim under the terms of this guarantee. ^ ^ This product conforms to the EMC-Requirements as laid down by the I t Council Directive 89/336/EEC and to the Low Voltage Regulation (23/73 EEC) 11 6405IM.indd 11 12.11.2008 11:21:13 Русский Метеостанция VT-6405 Перед подключением, использованием или настройкой устройства внимательно прочитайте инструкцию. Необходимо соблюдать все предупреждения и рекомендации по эксплуатации устройства, приведенные в этой инструкции. Сохраните инструкцию, используйте ее в дальнейшем в качестве справочного материала. ВНИМАНИЕ! Опасность удара электрическим током! НЕ ВСКРЫВАТЬ! Предупреждение: во избежание возникновения пожара или поражения электрическим током не подвергайте устройство воздействию дождя или влаги. Чтобы избежать удара электрическим током, не открывайте корпус устройства самостоятельно. Сервисное обслуживание должно осуществляться только квалифицированными специалистами сервисных центров. Значок молнии в равностороннем треугольнике указывает пользователю на наличие опасного напряжения внутри корпуса устройства, которое может привести к поражению электрическим токо...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories