Purpose of the Voltage Protector Module is to shut the Dispenser down should a too low or a too high power voltage condition occur. Retain these instructions as part of your equipment manual. LOOSE-SHIPPED PARTS Note: Only qualified personnel should install this Kit. Unpack and inspect kit. Make sure items are present and in good condition. Table 1. Loose-Shipped Parts Item No. Part No. Name Qty 1 XXXXXXXXX Voltage Protector Module 1 2 560003334 Electrical Wire (brown) 1 3 560003335 Electrical Wire (black) 1 4 560003336 Electrical Wire (blue) 1 5 325282000 Screw, Hex Washer Hd; Self-Drilling, No. 8-18 Thread by 1/2-inch Long 4 KIT INSTALLATION A WARNING: To avoid possible fatal electrical shock or serious injury to Installer, make sure Dispenser is disconneced from power source before attempting to install this kit. 1. Disconnect electrical power from the Dispenser 2. Remove screw securing the hood, then lift hood straight up off the Dispenser. 3. Remove two screws securing the electrical control box cover, then remove cover for access to the control board. NOTE: It may be necessary to relocate the transformer to make room for installation of the VOLTAGE PROTECTOR MODULE (item 1) on the refrigeration deck as shown in Figure 1. 4. Remove two screws securing the transformer to the refrigeration deck. Discard the two transformer retaining screws. July 21, 1998 ©IMI Cornelius Inc; 1998 OBSOLETE 569000242 FIGURE 1. TRANSFORMER/VOLTAGE PROTECTOR MODULE LOCATION 5. Place the transformer and the VOLTAGE PROTECTOR MODULE (item 1) on the refrigeration deck in approximate locations as shown in Figure 1. 6. Using the transformer and the VOLTAGE PROTECTOR MODULE (item 1) as templates, mark their mounting holes locations on the refrigeration deck. 7. Using a 9/64 drill bit, center punch and drill the four mounting holes in the refrigeration deck. 8. Install transformer and VOLTAGE PROTECTOR MODULE (item 1) on the refrigeration deck and secure with SCREWS (item 5). NOTE: Refer to Figure 2 (WIRING DIAGRAM) when making wiring connections between the Voltage Protector Module and the Control Board. 9. Connect one end of the black ELECTRICAL WIRE (item 3) to “LIVE OUT” terminal on the Voltage Protector Module. 10. Disconnect Compressor black electrical wire from “SW. COMP” terminal on the Control Board. 11. Connect other end of the black electrical wire, connected to “LIVE OUT” terminal on the Voltage Protector Module, to compressor black electrical wire disconnected from the control board “SW. COMP” terminal in preceding step 10. 12. Connect one end of the blue ELECTRICAL WIRE (item 4) to “LIVE IN” terminal on the Voltage Protector Module. 13. Connect other end of the blue ELECTRICAL WIRE (item 4) to “SW. COMP” terminal on control board where compressor electrical wire was disconnected from in step 10 preceding. 14. Connect one end of the brown ELECTRICAL WIRE (item 2) to “L2” terminal on the control board. This connection consi...
Ce manuel est également adapté pour les modèles :Dispensers - 50Hz (67.03 kb)