|
Facilité d'utilisation
Under the plate there is a channel and an outlet for defrost water. Regularly check the defrost water outlet and the drain channel for blockage. They should always be kept free and clean of particles. WE RESERVE THE RIGHT TO ALTER THE SPECIFICATIONS WITH NO EFFECT ON THE OPERATION OF THE APPLIANCE. Temperature Control The temperature of the appliance is controlled by setting the thermostat knob to a desired setting. Temperature Selection To turn the control to the "OFF" position, rotate the To start the appliance turn the temperature control control knob to the "0" position. If the appliance knob to the position corresponding to the desired has been left out of use for some time, set the cooling. control to maximum or the "7" position for 2-3 Fig A (MCWC16M) see page 6 hours before turning to the desired position. If the Fig B (MCWC30M) see page 6 appliance is not being used for long time periods, The temperature will vary depending on the disconnect the plug and leave the door partially quantity of the item stored and on the frequency open. This will help to reduce mold/mildew from with which the door is opened. accumulating inside the appliance cabinet. 5 CONTROL KNOB Fig A (MCWC16M) Fig B (MCWC30M) . Changes in ambient room temperature will affect the internal temperatures (choose correctsetting of the thermostat knob). . In STOP (0) position the appliance does not operate (cooling system is switched off ), yet power supply is not interrupted. . Temperature in the appliance also depends on how often the door is opened. ILLUSTRATION OF THE APPLIANCE 1. THERMOSTAT DIAL: For controlling the temperature inside the wine cooler. Turns the motor on as soon as the temperature rises above the desired level. 2. PLASTIC COATED SHELVES: Odor resistant, rustproof, and removable for easy cleaning. 3. MAGNETIC GASKET: Tight fitting door seal keeps all the cooling power locked inside. No hooks or latches. 4. TEMPERED GLASS DOOR & INTERIOR LIGHT: Allows easy interior visibility. (Interior light for MCWC30M only) TEMPERATURE RANGE GUIDE: Upper-Section Mid-Section Lower-Section 0 00 MIN. 19.0 /66.2 F 17.0 /62.6 F 14.0 /57.2 F 0 00 MED. 17.0 /62.6 F 14.0 /57.2 F 10.0 /50.0 F 0 00 MAX. 13.6 /56.4 F 9.8 /49.6 F 5.5 /41.9 F The above temperatures may fluctuate between +/- 5 6 Maintenance and Cleaning Automatic Defrosting of the Appliance There is no need to defrost the chiller , because ice depositing on the inner back wall is defrosted automatically. Ice build-up on the inner back wall during the compressor operation will defrost automatically (when the compressor has cycled off) . Defrost water will drain out passing through the drain outlet in the inner back wall into a drain pan situated above the compressor, from where it evaporates. Cleaning the Appliance Switch Off the Appliance When Not In Use If you do not intend to use the appliance for long periods of time. Set the thermostat knob to the STOP (0) position, disconnect the power supply, take out the contents and defrost and clean the appliance. Leave the door slightly open. Disconnect the power supply before cleaning the appliance. Do not use coarse or aggressive cleaning agents as you may damage the surface. Clean the exterior with water and detergent. Remove the detachable accessories in the interior of the appliance and clean with water and liquid detergent. Plastic parts cannot be washed in dishwashers. Wash the interior of the appliance with lukewarm water , adding one or two spoonfuls of vinegar. After cleaning, connect the appliance to power supply and reload it. 7 Trouble-Shooting Guide . Sometimes you may come across minor problems that in most cases do not require a service call and can be easily eliminated. The problem may have resulted from improper handing and / or installation of the appliance. Please refer to the below trouble-shooting guide to assist you in identifying the possible cause and solution to your problem. Should the problem still persist after completing these checkpoints. Contact the closest authorized service agent in your area for assistance. The Appliance Fails to Operate After Connecting to Electrical Power Supply . Check the power cord is properly connected. . Check the power supply in the electrical outlet. (blown fuse / circuit breaker) . . Make sure the appliance is switched on. (thermostat knob in operating position) Continuous Operation of the Cooling System . The door is frequently opened or left open for too long. . The door is not properly closed (the door may sag, the gasket may be polluted or damaged). . Perhaps you may have overloaded the appliance. . The reason may be inadequate ventilation of the compressor (assure adequate air circulation). Ice Formation on the Inner Rear Wall As long as the defrost water runs to the channel and through the outlet to the drain pan on the compressor, automatic defrosting of the appliance is assured. In case the ice formation on the inner back wall is increased (1/8-1/5in.), ice should be ...
Ce manuel est également adapté pour les modèles :Dispensers - MCWC16M (689.52 kb)