Log:
Évaluations - 3, GPA: 4 ( )

Instructions Clover Electronics, Modèle CLOVER WATER COOLERS B7B

Fabricant : Clover Electronics
Taille : 4.01 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


CAN CAUSE PHYSICAL DAMAGE TO THE UNIT. F. ('heck the available power supply against the water cooler data plate to assure correct electrical service. G. Allow cooler to operate about 30 minutes for chilled and hot water dispensing. CAUTION : WATER FROM HOT FAUCET CAN SCALD. H. Hot Water Safer Faucet : A safer faucet Lhat deters accidental dispensing of water by toddlers is available. This new faucet is simple and easy to use with one hand. О 5. STORAGE A. Disconnect power supply cord. B. Remove water bottle from cooler. C. Open faucet(s) to drain water D. Hot Models- Place the hot water switch in the "OFF" position. Draw water from the hot faucet until the water is cool. Place a bucket under the drain. Open the drain pipe by turning the drain cap, and drain the water from hot water tank. Turn the drain cap to a closed position when tank is empty. K. ALWAYS DRAIN AI.L WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE SHIPPING THE WATER COOLER. 6. CLEANING A. Disconnect the power supply during cleaning and inspection to avoid the dangers of electric shocks. B. Keep the condenser free from dirt and dust. The cooling ix?rformance decreases when the condenser is soiled. C. Cabinet, top cover ring and drip tray can be cleaned with any non abrasive household cleaner. To prevent damage to plastic parts, avoid abrasive cleaning aids such as steel wool, etc. O 7. WIKING DIAGRAM HOT CONTROL I Kir TASK HEATER HEAT limiter O— o~ 220-240 VOLT HOT TANK M0DK1 HOT TANK HEATER _ HO I CONTROL n y~ íiÜL HEAT limiter 100 127 V01.T HOT TASK MODELS COMPRESSOR mod:* HOT TANK SWITCH OVERLOAD V¿L PF9TECTOR \BK(B8) 1 BKIÜRJ / SW([IL) V W(UU / ) V W BK,BR) '©töKsT ©pif- POWER CORD * •-Í- COII) WATER Y 220-240 VOLT MODHI-S BK WIRLt -© APPLICABLE TO HOT MODEL UNITS \HK(HRI 1 HKIIiKi / J \WfBL) ?, V w(nu ) v -© /T\ UKIDK) A W G/WSt POWER WBU CORD 100-127 VOLT MODELS Il-i04-00j 8. TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE REMEDY REFRIGERATION SYSTEM No electric power to outlet. Turn on electric power outlet. A. The unit's compressor does not run. The temperature control is misadjustable or defective. Adjust or replace the temixrrature control, as necessary. The wires leading to the temperature control are defective or arc not connected. Check the internal wiring. Make repairs as necessary. The line voltage is low Cheek the line voltage. It must be at leasL 90% of minimum voltage. The compressor over load protector(OLP) is defective. Replace the defective over load protector. The starting relay (PTC) is defective. Replace the starting relay. The compressor is defective. Replace the compressor. Return cooler to authorized service center or factory for repair. 11. Water is adequately chilled, but unit runs excessively or continuously. Poor ventilation. Minimum side & rear clearance 'TOO«). The condenser is dirty or restricted. Clean the condenser or relocate the unit to prevent restricting the condenser. The lemjKirature control is defective (the contacts arc shorted or the control is not adjusted pro[>erly) Replace or adjust the temperature control as necessary. The ambient temperature is high It is normal for the unit to run continuously at high ambient temperatures. C. The unit compressor runs continuously, but there is no cold water. There has been a substantia loss in the sealed system's charge of refrigerant. If refrigerant leak is suspected, return cooler to authorized service center or factory for repair. The compressor is defective. Same as above. o TROUBLE POSSIBLE CAUSE REMEDY Cold water baffle is not in place Check inside the reservoir to make sure baffle is fully inserted into the mating socket. The condenser is dirty or restricted. Clean the condenser and relocate the unit to prevent restricting the condenser. D. The units excessively aiui the? cold water is not The cold water thermostat is set high and or the unit is in a high ambient environment. Check the thermostat setting. Adjust the selling as necessary. cold enough. Usage of the cold water system is greater than the unit capacity. nfonn the customer of the lot water system's maximum capacity. The refrigeration system is overcharged or undercharge. Kclurn cooler lo authorized There is a partial restriction in the refrigeration system. service center or factory for repair. The compressor is defective. If wattage readings are normal, the temperature control may be defective. Replace the temperature control. E. The unit has a short running cycle. It is cooling, hut docs not run long enough to cool water to The temperature control is improperly set for the prevailing environmental conditions and unit usage. Adjust the temperature control. the required level. The compressor motor is defective, causing the unit to cycle on the overload protector. Replace the compressor. Return cooler lo authorized service cen...

Ce manuel est également adapté pour les modèles :
Dispensers - CLOVER WATER COOLERS B7A (4.01 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories