Log:
Téléchargements : 5   Taille : 33 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

All necessary material to make the change, along with this bulletin, is included in a kit. The kit contents are listed below. Note that this kit will work for all models, regardless of voltage. Millennium II - Kit No. 629087501 Fitting (Qty. 6) 77050300 O-Ring (Qty. 6) 31525003 Clamp (Qty. 12) 40502 Tubing (Qty. 18 in.) 50299 Instruction Sheet 620919561 Procedure 1. Turn off the water supply to the dispenser. Disconnect power from the dispenser. Remove the top panel and merchandiser. No

Téléchargements : 5   Taille : 36 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

Any damage or irregularities should be noted at the time of delivery and immediately reported to the delivery carrier. Request a written inspection report from Claims Inspector to substantiate any necessary claim. Claims must be filed with the delivery carrier. SELECTING A LOCATION CAUTION: Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained according to federal, state and local laws. The dispenser must be located near a perma

Téléchargements : 0   Taille : 36 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

Make sure all kit items are present and in good condition. Table 1. Loose-Shipped Parts Item No. Part No. Name Qty. 1 314072000 Agitator Motor Ass’y, 115 VAC (Kit P/N 569000207) 1 314150000 Agitator Motor Ass’y, 230 VAC (Kit P/N 569000208) 1 2 319828000 Screw, Thread Rolling, Phil Pn Hd; No. 10-24, .375 Long 3 3 560001745 Mounting Template 1 4 000268010 Drill Bit, 5/32 1 REMOVING OLD AGITATOR MOTOR ASSEMBLY WARNING: Disconnect electrical power from the Unit to prevent personal injur

Téléchargements : 1   Taille : 36 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

Remove adhesive covering from back side of the mounting template, then place template (align template holes with existing agitator motor mounting holes) over the existing agitator motor cut-out in the refrigeration deck. 2. Temporarily install the electrical control box cover to protect the PC boards from metal shavings while drilling. Center punch two hole locations indicated on the mounting template, then using DRILL BIT (item 4) drill indicated holes in the refrigeration deck. ©IMI Corneliu

Téléchargements : 0   Taille : 40 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

The purpose of the Keyed Lock-Out Switch is to shut off electrical power to the dispensing valves to prevent dispensing of product. Retain these instructions as part of your equipment manual. LOOSE-SHIPPED PARTS Note: Only qualified personnel should install this Kit. Unpack and inspect kit. Make sure items are present and in good condition. Table 1. Loose-Shipped Parts Item No. Part No. Name Qty 1 560003869 Wiring Harness 1 2 560003870 Template, Hole Drilling 1 3 318948000 Lock Key 1

Téléchargements : 4   Taille : 40 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

Retain these instructions as part of your equipment manual. LOOSE-SHIPPED PARTS Note: Only qualified personnel should install this Kit. Unpack and inspect kit. Make sure items are present and in good condition. Table 1. Loose-Shipped Parts Item No. Part No. Name Qty 1 560003869 Wiring Harness 1 2 560003870 Template, Hole Drilling 1 3 318948000 Lock Key 1 4 318949000 Hex Nut 1 5 318569000 Key-Lock Switch 1 6 569000261 Installation Instructions 1 KIT INSTALLATION A WARNING: To avoi

Téléchargements : 2   Taille : 40 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

WIRING DIAGRAM 2

Téléchargements : 10   Taille : 40 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

DISPENSER HOOD 6. Install KEY-LOCK SWITCH (item 5) in the hood as shown in Figure 1 and secure with HEX NUT (item 4). 7. Refering to Wiring Diagram (Figure 2) disconnect black electrical wire, with push-on terminal on it’s end, from terminal on the transformer outlet. 8. Connect black electrical wire, disconnected from the transformer outlet terminal, to mating electrical wire terminal on the WIRING HARNESS (item 1). 9. Connect other electrical wire of the wiring harness to output terminal o

Téléchargements : 5   Taille : 40 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

The purpose of the Keyed Lock-Out Switch is to shut off electrical power to the dispensing valves to prevent dispensing of product. Retain these instructions as part of your equipment manual. LOOSE-SHIPPED PARTS Note: Only qualified personnel should install this Kit. Unpack and inspect kit. Make sure items are present and in good condition. Table 1. Loose-Shipped Parts Item No. Part No. Name Qty 1 560003869 Wiring Harness 1 2 560003870 Template, Hole Drilling 1 3 318948000 Lock Key 1

Téléchargements : 4   Taille : 40 kb   Fabricant : Cornelius  
Catégorie : Dispensers
@name

The purpose of the Keyed Lock-Out Switch is to shut off electrical power to the dispensing valves to prevent dispensing of product. Retain these instructions as part of your equipment manual. LOOSE-SHIPPED PARTS Note: Only qualified personnel should install this Kit. Unpack and inspect kit. Make sure items are present and in good condition. Table 1. Loose-Shipped Parts Item No. Part No. Name Qty 1 560003869 Wiring Harness 1 2 560003870 Template, Hole Drilling 1 3 318948000 Lock Key 1