Fabricant : PYLE Audio
Taille : 467 kb
Nom Fichier : 76987b95-fea2-4706-bdf9-5d7872dca387.pdf
|
Facilité d'utilisation
#1 approximately 70-80 ft./lbs. Torque #2 approximately 80-90 ft./lbs. Torque #3 approximately 90-100 ft./lbs. Torque #4 approximately 100-125 ft./lbs. Torque Line up desired torque # with raised pin Air Inlet Trigger Button Torque Regulator 5- ENG . . Place tool in forward or reverse position. Push button in on “F” side for forward or “R” side for reverse. . Depress the trigger to operate tool. . Release trigger to stop tool. . Always disconnect air supply when changing sockets. Push button all the way in on the “F” side for Forward position. When job is complete, turn the air compressor off and store as described in the air compressor operator manual. Push button all the way in on the “R” side for Reverse position. MAINTENANCE Lubrication Air tools require lubrication throughout the life of the tool. The air motor and bearing uses compressed air to power the tool. Because moisture in compressed air will rust the air motor, you must lubricate the motor daily. An inline oiler is recommended. To lubricate the air motor manually: 1. Disconnect the tool from the air supply holding it so the air inlet faces up. 2. Depress the trigger and place one to two drops of air tool oil in the air inlet Depressing the trigger helps circulate oil in the motor. NOTE: Use SAE #10 weight oil if air tool oil is not available. 3. Connect the tool to an air source, cover the exhaust end with a towel and run for a few seconds. Any excess oil in the motor is immediately expelled from the exhaust port. Always direct exhaust port away from people or objects. Failure to lubricate the tool at the air inlet will void your warranty. . 6- ENG 7- ENG REPAIR PARTS 7 8 30 18 29 22 17 25 28 21 27 24 46 (2) (2) 26 Ref No. Part No. Description Qty 7 s Anvil Collar 1 8 s Anvil 1 17 + Trigger 1 18 s Rubber Grip 1 21 s + O-Ring 1 22 + Spring Pin 1 24 + O-Ring 1 25 + Valve Body 1 26 + O-Ring 2 27 + Valve Stem 1 28 + Regulator Bushing 1 29 + E-Ring 1 30 + Spring Pin 1 46 + Spring 1 + Only available in Trigger Repair Kit D25450 s Only available in Service Kit D25462 NOTE: Parts not listed are not serviceable LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM. 2 YEARS -Limited warranty on oil-lubricated air compressor pumps. 1 YEAR -Limited warranty on all other air compressor components. 2 YEARS -Limited warranty on electric generator alternators. 1 YEAR - Limited warranty on other generator components. 2 YEARS -Limited warranty on pneumatic air tools as described in Porter-Cable general catalog. 1 YEAR -Limited warranty on pressure washers used in consumer applications (i.e. personal residential household usage only). 90 DAY -Pressure washers used for commercial applications (income producing) and service parts. 1 YEAR -Limited warranty on all accessories. Porter-Cable will repair or replace, at Porter-Cable's option, products or components which have failed within the warranty period. Service will be scheduled according to the normal work flow and business hours at the service center location, and the availability of replacement parts. All decisions of Porter-Cable Corporation with regard to this limited warranty shall be final. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. RESPONSIBILITY OF ORIGINAL PURCHASER (initial User): • To process a warranty claim on this product, DO NOT return it to the retailer. The product must be evaluated by an Porter-Cable Authorized Warranty Service Center. For the location of the nearest Porter-Cable Authorized Warranty Service Center call 1-888-559-8550, 24 hours a day, 7 days a week. • Retain original cash register sales receipt as proof of purchase for warranty work. • Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s). • Deliver or ship the product to the nearest Porter-Cable Authorized Warranty Service Center. Freight costs, if any, must be paid by the purchaser. • Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation. Contact the nearest Porter- Cable Authorized Warranty Service Center that provides on-site service calls, for service call arrangements. • If the purchaser does not receive satisfactory results from the Porter-Cable Authorized Warranty Service Center, the purchaser should contact Porter-Cable. THIS WARRANTY DOES NOT COVER: • Merchandise sold as reconditioned, used as rental equipment, and floor or display models. • Merchandise that has become damaged or inoperative because of ordinary wear, misuse*, cold, heat, rain, excessive humidity, freeze damage, use of imprope...
Ce manuel est également adapté pour les modèles :Perceuses et shuropopverty - PT382 (467 kb)