Log:
Évaluations - 0, GPA: 0 ( )

Instructions Bosch, Modèle BS471110/04

Fabricant : Bosch
Taille : 644.97 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :
Fours - BS471110/04 (645.69 kb)
Fours - BS471110/04 (645.17 kb)
Fours - BS471110/04 (643.04 kb)
Fours - BS471110/04 (742.43 kb)

Facilité d'utilisation


2 Confirm with ™. ...................... Setting the clock The time is shown in the display. 1 Set the desired time using the rotary selector. 2 Confirm with ™. .................. Setting the date format The three possible formats D.M.Y, D/M/Y and M/D/Y appear in the display. The default is the D.M.Y format. 1 Use the rotary selector to select the desired format. 2 Confirm with ™. ...................... Setting the date The preset date appears in the display. The day setting is already active. 1 Set the day using the rotary selector. 2 Touch the C symbol to switch to the month setting. 3 Set the month using the rotary selector. 4 Touch the C symbol to switch to the year setting. 5 Set the year using the rotary selector. 6 Confirm with ™. ........ Setting the temperature format The two possible formats °C and °F appear in the display. The default setting is °C. 1 Use the rotary selector to select the desired format. 2 Confirm with ™. .................................... Setting the water filter "Water filter" appears in the display. The default is "Available". It is recommended to install the descaling system GF 111 100 if the water hardness exceeds 7°dH (carbonate hardness 5°dH). 1 Use the rotary selector to select "Available" (with water filter) or "Not available" (without water filter). 2 Confirm with ™. 3 If water filter "Available" has been selected: "Water filter capacity” is shown in the display. 4 Turn the rotary selector to select the capacity of the filter cartridge (between 100 - 9000 litres). Refer to the instructions included with the filter cartridge. 5 Confirm with ™. .......................................... Setting the water hardness "Water hardness" appears in the display. 1 Check the mains water with the included carbonate hardness test: fill the small measurement tube with mains water up to the 5 ml mark. 2 Add drops of indicator solution until the color changes from purple to yellow. Important: count the drops and carefully swing the measurement tube after every drop until the liquids have mixed thoroughly. The number of drops corresponds to the water hardness. 3 Use the rotary selector to set the measured water hardness. The value 12 is set by default. 4 Confirm with ™. ................................ Ending initial set-up "Initial set-up complete. Please calibrate the appliance before first cooking." appears in the display. Confirm with ™. ...................................................................................................................................................... The appliance enters standby mode and the standby screen appears. The appliance is now ready for operation. Calibrate the appliance before steaming for the first time. The appliance sets the boiling point. Calibration The boiling point of water depends on barometric pressure. As air pressure drops with increasing elevation, the boiling point drops as well. During calibration, the appliance sets the boiling point to the pressure conditions at the place where it is installed. It is important that the appliance steams without interruption for 20 minutes at 100°C. Do not open the appliance door during this time. Notes .Calibrate the appliance only when it is cold. .During calibration, the appliance generates more steam than it normally would do. 1 Turn the function selector to S. 2 Select "Basic settings" using the rotary selector. 3 Touch the ™ symbol. 4 Select "Calibration" using the rotary selector. 5 Touch the % symbol. 6 Remove all accessories from the oven interior and touch the ™ symbol. 7 The duration of 20:00 minutes appears. Touch I to start calibration. Calibration begins. The elapsing time is shown on the display. ................ Note: Do not interrupt calibration. Do not turn the function selector. Do not open the appliance door. A message appears in the display once calibration has ended. Touch ™ to confirm and turn the function selector to 0. After moving house Repeat calibration so that the appliance adapts automatically to the new installation location. After resetting to the factory settings After resetting to the factory settings in the basic settings menu, you must repeat calibration. Following a power cut The appliance saves the calibration settings even in the event of a power cut or disconnection from the mains. Recalibration is not necessary. Grease filter Hook the enclosed grease filter onto the hot air grille in the side wall of the cooking compartment. Remove the left slide-in rail first (see section entitled Removing slide-in rails). Leave the grease filter in the cooking compartment for all applications. Clean the grease filter with hot soapy water or in the dishwasher every time heavy dirt deposits have been left behind after cooking. Cleaning accessories Before using the accessories for the first time, clean them thoroughly using hot detergent solution and a soft cloth. ...................................... Water filter Operation with or without a water filter You can use...

Ce manuel est également adapté pour les modèles :
Fours - BS474110/04 (644.97 kb)
Fours - BS475110/04 (644.97 kb)
Fours - BS484110/04 (644.97 kb)
Fours - BS485110/04 (644.97 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories