Log:
Évaluations - 4, GPA: 4 ( )

Instructions American Dryer, Modèle DR-NSS

Fabricant : American Dryer
Taille : 141.24 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Dryer shall deliver 160 CFM at 5500 LFM. Push button dryers shall be activated by a cam-operated mechanical timer. Cover shall be attached with one tamper-resistant bolt and a 3” steel latch which locks it securely to base. Tamper- resistant air intake vents, internal shield and side mounted heating element are for additional safety. Heating element is protected by an automatic resetting circuit breaker. Nozzle and push button shall be zinc die castings with a chrome plated finish. Nozzle shall revolve 360. unless specified as fixed position. UL and C-UL listed. Made in the U.S.A. DR Series Surface Mounted 10 13/16 (274 mm) 2 3/4 (70 mm) 5/8 (17 mm) 1 5/16 (33 mm) 7/8 (22mm) DIA. IN-WALL CONDUIT ENTRANCE 7 7/16 (189 mm) 9 1/16 (230 mm) 7/8 (22mm) DIA. SURFACE CONDUIT ENTRANCE Installation (Surface Mount) 5/8 (4) MTG HOLES 5/16 DIA. (8 mm) (Refer to recessed instructions for recessed mounting) WARNING: DISCONNECT POWER BEFORE INSTALLING 1. To remove cover, remove special Allen screw using wrench supplied. Place a hand on each side of cover and pull bottom toward you about 1/4 inch, then push cover up toward top of dryer, releasing cover from mounting plate latch. Lift cover off mounting plate by pulling forward at the bottom and upward at the same time. DO NOT FORCE COVER OFF. 2. Dryers should be placed at least 2 feet (61cm) apart and at least 12” (30cm) from washbasin. Do not install dryers over washbasin. Hold the backplate to the wall at the suggested mounting height. Measure from bottom edge of backplate to the floor. 3. Mark the locations of the four mounting holes and the conduit entrance location on the wall. (The conduit entrance is the proper hole diameter for 1/2 inch (13mm) conduit.) 4. Fasten the backplate to the wall where previously marked. RECOMMENDATION: Wood wall - No. 16 (M8) wood screws, 2 3/4”(70mm) long Cement or brick - 1/4” (M6) stud expansion bolts, 3” (76mm) long Hollow wall - 1/4” (M6) toggle bolts, length depends on wall thickness 5. Run service wire to dryer location and connect to terminal block. IMPORTANT: All units must be supplied with a 3 wire service. Use No. 12 wire or larger as required by local electrical code. The ground wire must be connected to the dryer backplate. Unit must be installed by a qualified licensed electrician. Do not connect any unit to a branch circuit over 20 amps. Dryers located in shower rooms or other wet locations should be equipped with ground fault interrupter(s). 6. Carefully replace the cover using tamper-proof bolts supplied. 1 1/4 1 (25 mm) (32 mm) 5/8 (17 mm) 9 1/2 (241 mm) DR Series Recess Mounted ROUGH OPENING 11 3/4” W (30cm) X 12 3/4” H 932cm) Operating Costs The only operating cost for the DR series hand dryer is electricity. Based on a cost of $0.10 per KWH: Cost per 1,000 hand dryings DR series = $1.92 Paper Towels = $20.56 Warranty 10-year limited warranty includes same day factory repair or part replacement. Sensor 3 years. See owner’s manual for details. US C American Dr...

Ce manuel est également adapté pour les modèles :
Séchoirs - DR-N (141.24 kb)
Séchoirs - DR-NH (141.24 kb)
Séchoirs - DR-NHSS (141.24 kb)
Séchoirs - DR-TN (141.24 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories