Facilité d'utilisation
Remove flue cap #6 by removing six (6) [#10] sheet metal screws. 2. Remove front panel #5 by lifting upward. 3. With back panel #4 still attached to the left #2 and right #3 uprights, drop uprights into the rectangular cutouts at the rear of the range #1. 4. Fasten uprights #2 and #3 to the range #1 with four (4) 5/16” -18 bolts and flat washers #7 and #8. 5. If unit is in a battery lineup, fasten adjacent units together at hole marked “X” with .” -20 bolts, nuts, and washers. 6. Install front panel #5 previously remove 7. Install flue cap #6 previously removed ~ ~ 1 "X" "X" 2 5 8 7 36 9 4 Assembly Instructions M-Series Backguard 1. Remove front panel #5 by lifting upward. 2. With back panel #4 still attached to the left #2 and right #3 uprights, drop uprights into the rectangular cutouts at the rear of the range. 3. Fasten uprights #2 and #3 to the range #1 with four (4) 5/16” -18 bolts and flat washers #6 and #7. 4. If unit is in a battery line up, fasten adjacent units together at hole marked “X” with .” -20 bolts and washers. 5. Install front panel #5 previously removed. Attach front panel #5 to range #1 with sheet metal screws. 1 "X" 2 5 4 3 6 7 8 "X" Part # 1382677 (08/06) Page 9 INSTALLATION Continued METHOD OF ATTACHING RADIATION SHIELD TO BACKGUARD OR HIGH SHELF RADIATION SHIELD REMOVE EXISTING #10 SHEET METAL SCREWS (2 REQ'D) FROM HIGH SHELF OR BACKGUARD TO INSTALL RADIATION SHIELD FIGURE 1 Radiation Shield This radiation shield must be in place when fryer is installed in other than fire resistive locations. BACK ALUMINIZED IMPORTANT: The flue riser must be installed within FLUE RISER the back guard. This rectangular riser fits over the collar of the flue collector box inside the fryer. Place the flue riser upright through opening in the back top and slide over collar. (See Figure ..). FIGURE 2 SIDES AND FRONT HEAT SHIELD OPERATION Using the Fryer for the First Time Before lighting the pilot, fill the frypot with frying compound. Then light the pilot according to the instructions inside the fryer compartment on the inner panel. If you are using a cooking oil, you may now turn the main burner on by turning the knob on the automatic gas valve. If you use a hydrogenated (solid) frying compound, it is wise to melt it in a stock pot on the range before putting it in the fryer. If this is not done, pack the frypot with the compound and turn the main burner on for a few seconds and turn it off for a few. See the lighting and shut-down instructions for “How to turn on the main burner once the pilot is lighted.” Intervals of about three seconds on and ten seconds off are about right. Keep doing this until the shortening is melted. If any smoke is seen during this process, you are heating too fast and scorching the shortening, thus cutting down its useful life and possible damaging the frypot. Shortening level must cover the thermostat bulbs when fryer is in operation. After turning the main burner on, set the thermostat at ...° to check calibration of the thermostat. Let the burner cycle at least four times and suspend a deep fat fryer thermometer in the middle of the frypot about .” deep. When the burner just comes on after the fourth cycle, the reading on the thermostat should agree with the thermostat setting. If not, calibrate the thermostat Page 10 Part # 1382677 (08/06) OPERATION Continued according to the instructions in the Cleaning and Maintenance Section of this manual. Lighting Instructions For specific models see “Lighting Instructions” on the inside of fryer compartment. (Frypot must be filled before lighting). 1. Turn thermostat knob to the frying temperature. The thermostat knob is located inside the compartment in the front of the frypot. 2. Open the fryer door and turn the combination safety valve knob to the PILOT position. 3. Push the knob in, light the pilot and continue to hold knob in for about sixty seconds after the flame has been lit. 4. Turn valve knob counter-clockwise to ON. 5. Main burners will now light and will be controlled automatically by the thermostat NOOFFPILOT AUTOMATIC VALVE KNOB PILOT POSITION NOOFFPILOTNOOFFPILOTAUTOMATIC VALVE KNOB ON POSITION AUTOMATIC VALVE KNOB OFF POSITION Part # 1382677 (08/06) NOTE: Fryer cannot be shut off at the thermostat. Thermostat used only to control temperatures. Stand By 1. Turn fryer gas valve knob to “PILOT” position. 2. Put frypot cover in place. Complete Shut Down Turn gas valve knob clockwise to pilot position, DEPRESS knob, slightly clockwise, release knob and continue turning clockwise to OFF. Safety Concerns WARNING: The operator should be aware of the HAZARDOUS NATURE, inadvertent splashing and spilling etc., and RESULTANT CONSEQUENCES, personal burns, fires, slipping on spilled liquid etc., when moving the fryer with liquid in the vessel. If the fryer is to be moved, it is recommended that the liquid in the vessel be cooled to room temperature and removed from the vessel. To assure you of maximum protection and performance ...
Ce manuel est également adapté pour les modèles :Fryers - M/MST35 (366.85 kb)