Instructions Delta, Modèle F-25

Fabricant : Delta
Taille : 1.54 mb
Nom Fichier : e7a000b6-705f-43a6-961c-9081f7cd9209.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


• Outer tank has a factory installed 30 psig relief valve rated at 535,000 Btu/hr • Electrical rating:120 V, 60 Hz, less than 12 amperes • pH & chloride limits for the ELITE are: -Chloride, less than 80 mg/l. -pH, 6.0 - 8.0. NOTICE Any water conditioning system must be installed and maintained in accordance with manufacturer’s specifications. • 180. Maximum operating temperature primary side. • 120. Maximum outlet/mixed temperature - domestic side. CODE RESTRICTIONS Single wall heat exchanger in the ELITE complies with National Standard Plumbing Code, provided that: -Outer tank water (including additives) is practically non-toxic, having toxicity rating or Class of 1, as listed in Clinical Toxicology of Commercial Products, -Outer tank pressure is limited to maximum 30 psig by approved relief valve. Single wall heat exchangers are permitted under the Uniform Plumbing code - Paragraph L3.2. if they satisfy all of the following requirements. 1. The heat transfer medium is potable water or contains only substances which are recognized as safe by the U.S. Food and Drug Administration. 2. The pressure of the heat transfer medium is maintained less than the normal minimum operating pressure of the potable water system 3. The equipment is permanently labeled to indicate that only additives recognized as safe by the FDA shall be used in the heat transfer medium. Or, per Uniform Plumbing Code paragraph L3.3 as follows: Other heat exchanger designs may be permitted where approved by the Administrative Authority. 4 Pre-Installation Items SECTION I - Pre-Installation Items Code Compliance This product must be installed in accordance to the following: • All applicable local, state, national and provincial codes, ordinances, regulations and laws. • The National Fuel Gas Code NFPA54/ ANSI Z332.1 - Latest edition. • Installation of Oil Burning Equipment NFPA 31 - Latest Edition • National Electric Code ANSI/NFPA 70. • For installations in Canada -“Installation Code for Gas Burning Equipment” CGA/B149. • For installations in Canada - Installation code for Oil Burning Equipment CSA/ B139. Determining Product Location Before locating the ELITE check for convenient locations to: - Domestic water supply piping - Heating system piping -Venting - Gas or oil supply piping - Electrical service Ensure the area chosen for the installation of the ELITE is free of any combustible materials, gasoline and other flammable liquids. WARNING Failure to remove or maintain the area free of combustible materials, gasoline and other flammable liquids or vapors can result in severe personal injury, death or substantial property damage. 5 Ensure the ELITE and its controls are protected from dripping or spraying water during normal operation or service. The ELITE should be installed in a location so that any water leaking from the tank or piping connections or relief valves will not cause damage to the area surrounding the unit or any lower floors in the structure. -When such a location is unavoidable a suitable drain pan with adequate drainage should be placed under the unit. The drain pan must not restrict the flow of combustion air to the unit. Boiler Replacement If the ELITE is replacing an existing boiler / hot water heater system, the following items should be checked and corrected prior to installation: • Primary and domestic piping leaks and corrosion. • Improper location and sizing of the expansion tank on the primary heating loop. • Improper sizing of the thermal expansion tank (if used) on the domestic supply line. •Vent condition and sizing. Recommended Clearances The ELITE is approved for zero clearance to combustibles, excluding the vent hood and vent piping. Vent hood and vent piping - 6 inches from combustible materials when using type “L” double wall vent. Vent Piping - 18 inches from combustible materials when using single wall vent. Primary and domestic hot water piping - 1 inch from combustible material. Pre-Installation Items BEST PRACTICES To provide serviceability to the unit it is recommended that the following clearances be maintained: Top and vent hood area - 36 inches. Front and burner area - 24 inches. Rear and primary piping areas - 12 inches. WARNING When installing the ELITE in a confined space, sufficient air must be provided for proper combustion and venting and to allow under normal operating condition, proper air flow around the product to maintain ambient temperatures within safe limits to comply with the National Fuel Gas Code NFPA 54 - latest edition. Flooring and Foundation The ELITE is approved for installation on combustible floors, but never on carpeting. WARNING Do not install the ELITE on carpeting even with a metal or wood foundation base. Fire can result causing severe personal injury, death or substantial property damage. Installer should provide a solid brick or concrete foundation pad, at least 2 inches above the floor level if: -There is a potential for the floor to become flooded. The height of the...

Ce manuel est également adapté pour les modèles :
électrique - F-25 (1.54 mb)
Radiateurs à gaz - 30 (1.54 mb)
Radiateurs à gaz - 35 (1.54 mb)
Radiateurs à gaz - 40 (1.54 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories