Facilité d'utilisation


Ashes must be disposed in a metal container with a tight lid and placed on a no combustible surface well away from the home structure. · This stove must be connected to a standard 120 V., 60 Hz grounded electrical outlet. Do not use an adapter plug or sever the grounding plug. Do not route the electrical cord underneath, in front of, or over the stove. · The exhaust system should be checked, at a minimum, at least twice a year for any build up of soot or creosote. · Keep foreign objects out of the hopper. · Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual. · Do not place clothing or other flammable items on or near the stove. · The viewing door must be closed and latched during operation. · Do not operate the stove if the flame becomes dark and sooty or if the burnpot overfills with pellets. Turn the stove off, periodically inspect it, and call your dealer. · Do not touch the hot surfaces of the heater. Educate all children of the danger of a high temperature stove. Young children should be supervised when they are in the same room as the stove. · If the stove is installed in a room without air conditioning, or in an area where direct sunlight can shine on the unit, it is possible this can cause the temperature of the stove to rise to operational levels; one of the sensors could then make the stove start on its own. It is recommended that the stove be unplugged when not in use for extended amounts of time (i.e. during the summer months). · The exhaust system must be completely airtight and properly installed. The pellet vent joints must be sealed with RTV 500°F. (260°C.) silicone sealant, and with UL181- AP foil tape. · Your stove requires periodic maintenance and cleaning. Failure to maintain your stove may lead to smoke spillage in your home. · This stove is designed and approved for pelletized wood fuel only. Any other type of fuel burned in this heater will void the warranty and safety listing. · When installed in a mobile home, the stove must be bolted to the floor, have outside air, and NOT BE INSTALLED IN A BEDROOM (Per H.U.D. requirements). Check with local building officials. · Breckwell Hearth Products grants no warranty, implied or stated, for the installation or maintenance of your stove, and assumes no responsibility of any consequential damage(s). 4 TABLE OF CONTENTS INTRODUCTION ---------------------------------------------------------------------------------------------2 SAFETY PRECAUTIONS ----------------------------------------------------------------------------------3 SPECIFICATIONS -------------------------------------------------------------------------------------------5 INSTALLATION ---------------------------------------------------------------------------------------------5 Preparation -----------------------------------------------------------------------------------------5 Clearances -----------------------------------------------------------------------------------------5 Combustion Air Supply --------------------------------------------------------------------------6 When Outside Air Is Not Used -----------------------------------------------------------------6 Venting -----------------------------------------------------------------------------------------------6 Freestanding Installations ----------------------------------------------------------------------7 Insert Installations --------------------------------------------------------------------------------10 Electrical Installation ------------------------------------------------------------------------------13 Special Mobil Home Requirements ----------------------------------------------------------13 OPERATION ---------------------------------------------------------------------------------------------------14 Proper Fuel -----------------------------------------------------------------------------------------14 Pre-Start-Up Check -------------------------------------------------------------------------------14 Building a Fire -------------------------------------------------------------------------------------14 The HotRod™ Automatic Fire Starter --------------------------------------------------------14 Panel Controls -------------------------------------------------------------------------------------14 Opening Door --------------------------------------------------------------------------------------15 Room Air Fan --------------------------------------------------------------------------------------15 Re-Starting a Warm Stove ----------------------------------------------------------------------15 If Stove Runs Out Of Pellets --------------------------------------------------------------------16 Damper Control ------------------------------------------------------------------------------------16 Refueling -------------------------------------------------------------------------------------...

Ce manuel est également adapté pour les modèles :
Radiateurs à gaz - ECONOMY P22FSA (742.9 kb)
Radiateurs à gaz - ECONOMY P22I (742.9 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories