Log:
Évaluations - 4, GPA: 4.3 ( )

Instructions Desa, Modèle GG30NT

Fabricant : Desa
Taille : 1.15 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes. Natural and Propane/LP Gas: Natural and propane/ LP gases are fuel gases. Fuel gases are odorless. An odor-making agent are added to fuel gases. The odor helps you detect a fuel gas leak. However, the odor added to fuel gas can fade. Fuel gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater. WARNING: Any change to this heater or its controls can be dangerous. WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater. Due to high temperatures, the appliance should be located out of trafficand awayfromfurniture and draperies. Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater. Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching. Carefully supervise young children when they are in the same room with heater. Make sure grill guard is in place before running heater. Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. 3. This heater shall not be installed in a bedroom or bathroom. 4. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor.s phone. Follow the gas supplier.s instructions • if you cannot reach your gas supplier, call the fire department 5. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5. 114683-01B SAFETY INFORMATION Continued 6. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion. 7. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 8. Do not run heater • where flammable liquids or vapors are used or stored • under dusty conditions 9. Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 10. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 11. Turn off and let cool before servicing. Only a qualified service person should service and repair heater. 12. Operating heater above elevations of 4,500 feet could cause pilot outage. 13. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity. 14. Provide adequate clearances around air openings. LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 PRODUCT IDENTIFICATION Control Knob Ignitor Button Heater Cabinet Front Panel Heat Shield Grill Guard Figure 1 - Vent-Free Gas Heater UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. PRODUCT FEATURES SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system requires no matches, batteries or other sources to light heater. THERMOSTATI...

Ce manuel est également adapté pour les modèles :
Radiateurs à gaz - BG30N (1.15 mb)
Radiateurs à gaz - BG30NT (1.15 mb)
Radiateurs à gaz - BG30P (1.15 mb)
Radiateurs à gaz - BG30PT (1.15 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories