Log:
Évaluations - 5, GPA: 3.8 ( )

Instructions ADTRAN, Modèle 61175044L2-22B

Fabricant : ADTRAN
Taille : 182.42 kb
Nom Fichier : fba197ba-8e3d-65a4-2960-f8c53877bd99.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


WARRANTY Warranty for Carrier Network products manufactured by ADTRAN and supplied under Buyer's order for use in the U. S. is ten (10) years. For a complete copy of ADTRAN's U. S. Carrier Networks Equipment Warranty: (877) 457-5007, Document 414. STATUS LEDS AC Power Operation (AC power only) Battery Operation ( AC power supply or battery backup) GREEN OK GREEN OK ( charging) YELLOW Power Fail YELLOW Discharging RED Power Fail RED Low ( < - 40 V) OFF Power Fail OFF Disconnected Alarm Relay ¦ Provided for customer use RELAYS Condition Alarm Relay Normal Open AC Power Failure/ Battery Backup engaged Cycles open/closed once per second if AC voltage <88 Vrms at full load and battery backup is connected Battery voltage < - 45V Stays closed if voltage < - 45 VDC to indicate that battery is becoming depleted Battery Disconnect Relay ¦ Disconnects battery pack from the system if the battery voltage falls below - 40 VDC ¦ Prevents damage to batteries CIRCUIT BREAKER ¦ 3- amp circuit breaker ¦ Protects unit from over - current ¦ Rocker button extends out from front panel when tripped ¦ Reset by pushing in on the rocker button GROUNDING ¦ An 18 AWG or larger ground wire is required to connect additional ground connector to "ground bus" in customer equipment room. ELECTRICAL SPECIFICATIONS TELECOMMUNICATIONS CODES ¦ AC input: 115 V nominal ¦ Range: 90 to 132 VAC ¦ DC output: -54 V, 60 W average, 100 W peak ¦ Battery charging: 16 hr nominal, 24 hr maximum ¦ Battery discharge: Up to 8 hours Code Input Output PC F TC — — IC E — C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. JOBAid, 61175044L2- 22B, December 2002 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright . 2002 ADTRAN, All Rights Reserved JOBAID 61175044L2-22B BATTERY BACKUP UNIT JOBAID 61175044L2-22B BATTERY BACKUP UNIT BATTERY BACKUP 1 UNIT P/ N: 1175044L2 CLEI: SIMPBBBARA 2 3 4 5 6 7 C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. Note: Battery BackupUnit is designed for use withthe TotalAccess 612, 616, 624, 750 and 850 units. MOUNTING INSTRUCTIONS Unpack the Total Access 750/ 850 Battery Backup Unit and inspect for damage. If damage is apparent, refer to your carrier or supplier for remedy. Note: Itis not necessary toremove the batteries during installation process. The battery box must be mounted with the following minimum clearances: Top- 9" (for Total Access 750/ 850) Top- 5" (for Total Access 612/ 616/ 624) Left Side-5" Right Side-1” Bottom- 3" Using the template provided, mark and drill three pilot holes for #10 mounting screws. Insert #10 x 3/ 4" flat- head wood screws ( supplied) into the three pilot holes, leaving 1/ 16" space between the screw- head and the backboard. CAUTION: Fully loaded Battery box weighs 30 lbs. Mount the battery box on the three support screws on the backboard. Remove the two closure screws on the battery box and open the cover. Use a long shaft screwdriver to tighten the three support screws. WARRANTY Warranty for Carrier Network products manufactured by ADTRAN and supplied under Buyer's order for use in the U. S. is ten ( 10) years, except for batteries which carry manufacturer's warranty. For a complete copy of ADTRAN's U. S. Carrier Network Equipment Warranty: (877) 457- 5007, Document 414. TELECOMMUNICATIONS CODES Code Input Output IC — C TC — — PC E — MAINTENANCE ¦ Life expectancy: 3- 5 years on standby use ¦ Battery performance is adversely affected by extreme emperatures. ¦ Old barreries should be recycled. Reference 60000120- 36A for further information. -48 VDC 1175044L2 BATTERY BACKUP BATTERY SPECIFICATIONS ¦ Batteries: 7 Amp/ hr (4 batteries per pack) ¦ Case size: 6" W x 3 3/ 4" H x 2 1/ 2" D Battery type: Lead acid Voltage: -54 VDC ¦ Backup Time: Up to 8 hours Wire Gauge: 18 AWG Preferred Temperature: 68 . F (20. C) The device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by AC Power Input -48 VDC Total Access 612/616/624 1175044L2 BATTERY BACKUP CAUTION During wall installation, position the Total Access 612/616/624 as shown in 61200624L1-19A. 9902271 LY L T- A T- B -48 R -48 V V.35 T1 FT1 MANAGEMENT DC POWER WARNING: 20 Hz FUSE MUST BE REMOVED BEFORE REMOVING COVER. Terminal access cover BATTERY INPUT AC ALARM OUTPUT -54VDC OUTPUT 120VAC/ 2A 60HZ INPUT GROUND + - To Alarms Total Access 750 AC/DC Power Supply Battery Charging Unit -54 VDC Output to Total Access 750 -54 VDC Battery Charging/Discharging LineAC Power Input P/N: 1175043Lx CAUTION! During Total Access 750 wall installation, position the chassis so front panels face up. ADTRAN could void the user's authority to operate this equipment. Note: The connection fortheTo...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories