Log:
Évaluations - 2, GPA: 4 ( )

Instructions APC, Modèle 2200

Fabricant : APC
Taille : 277 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The user manual is also available on the APC Web site at Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 4 Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Operation Connect Equipment to the UPS Note: The UPS will charge to 90% capacity in the first three hours of normal operation. Do not expect full battery run capability during this initial charge period. 1. Connect equipment to the outlets on the rear panel of the UPS. Do not use extension cords, plug equipment directly into the UPS. 2. Connect the UPS to the building utility power. Connect the UPS to a two-pole, three-wire, grounded receptacle only. 3. Press the ON/OFF button on the front panel of the UPS to apply power to the unit and all connected equipment. 4. To use the UPS as a master on/off switch, turn on all the equipment that is connected to the UPS. See “UPS Settings” on page 7 for information on how to configure the outlet groups. Rear Panel Features Serial port: Connect to a computer to use power management software. USB port: Connect to a computer to use power management software. Ground Screw: Connect the ground leads on transient voltage devices to the chassis ground screw(s), located on the rear panel of the UPS. su0441a Display Interface Overview Online indicator . . UPS Output On/Off button . On Battery indicator Fault indicator . . Replace Battery indicator . Display screen . UP/DOWN buttons ENTER button . ESCAPE button . su0343aAPC by Schneider Electric Using the display interface Use UP and DOWN to scroll through the main menu options. Press ENTER to view the sub-menus under each main menu option. Press ESCAPE to exit a sub-menu and return to a main menu. Standard menus The Standard menus are the most commonly used menus for the UPS. Menu General Functions Status View basic information about the UPS: • Operating mode • Switched Outlet status, On or Off • Efficiency of the UPS • Information about the load • Battery capacity • Estimated runtime • Input and output voltage and frequency • Information about the last transfer to battery power • Self-test results Configuration Configure the settings for the UPS: • Language • Local power quality: Good, Fair, Poor • Choose Standard or Advanced menus • LCD Display mode, Always On or Power-Saving • Audible alarms • Reset to Factory Defaults Test & Diags Use the Test & Diags menu to have the UPS perform a self-test. Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Menu General Functions About Display information about this unit: • Unit model number • Serial number • Battery installation date • Suggested battery replacement date • Replacement Battery Cartridge model number • UPS firmware version Advanced menus The Advanced menus provide additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. Menu General Functions Status View detailed information about the UPS: • Energy meter • Load current • Status of the Switched Outlet Group • Battery voltage Configuration Configure advanced settings for the UPS: • Main and Switched Outlet Group—delays and settings • High and lower transfer points • Sensitivity settings • Date of last battery replacement Control Control the Main and Switched Outlet Group to turn on, turn off, or reboot. Test & Diags Perform a UPS alarm test or a runtime calibration test. Log View the event log for information about any changes to the UPS and any faults. About View information about the unit: • Hardware version • Software version • NMC information (if applicable) Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Configuration UPS Settings Start-up Settings Configure these settings at initial start-up, using the display interface or APC PowerChute® software. Note: During start-up, use the display interface to configure these settings. If nothing is selected, the until will use the default settings. Function Factory Default Options Description Language English • English •French* •German* The language for the display interface. *Language options will vary by model. • Spanish* • Italian* Local Power Quality Good • Good •Fair • Poor Select the quality of input utility power. • If Good is selected, the unit will go on battery power more often to provide the cleanest power supply to the connected equipment. • If Poor is selected, the UPS will tolerate more fluctuations in power and will go on battery power less often. If unsure of the local power quality, select Good. Menu Type Standard Standard or Advanced The advanced menus include all parameters. The Standard menus display a limited set of menus and options. Display Mode Always On Always On or Power Saving The display may be always on or may be set to automatically turn on only when using the configuration buttons or if an event occurs. General Settings Configure these settings at any time, using the display interface or APC PowerChute® software. Function Factory Default Options Description High Transfer Point 120 V: 127 Vac • 127 ...

Ce manuel est également adapté pour les modèles :
Alimentation et alimentation - 1000 (277 kb)
Alimentation et alimentation - 750 (277 kb)
Alimentation et alimentation - 3000 (277 kb)
Alimentation et alimentation - 1500 (277 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories