Fabricant : American Power Conversion
Taille : 180.98 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


None. The UPS will restart automatically when utility power returns. All indicators are flashing. Internal UPS fault. Do not attempt to use the UPS. Turn the UPS “Off” and have it serviced immediately. The UPS operates normally, but the site wiring fault indicator is lit. Building wiring error such as missing ground or hot to neutral wire reversal. Have a qualified electrician correct the building wiring. On-line and on-battery indicators only are flashing Internal UPS fault. Do not attempt to use the UPS. Turn the UPS “Off” and have it serviced immediately. All indicators are “Off” and the UPS is not operating. The UPS is shutdown and the battery is discharged from an extended power outage. None. The UPS will return to normal operation when the power is restored and the battery has a sufficient charge. The replace battery light is illuminated. Weak batteries. Allow the batteries to recharge for at least 4 hours. If the problem persists after recharging, replace the batteries. Replacement batteries not connected properly. Confirm the battery connections. The overload light is illuminated or flashing The UPS is overloaded. Reduce the load on the UPS by unplugging equipment. Customers may return their defective unit to APC for replacement or repair during the standard 2 year warranty period. APC's standard procedure will be to replace the original unit with a factory-reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Customer Service. APC will ship out the replacement unit once the defective unit has been received by the repair department. The customer pays for the shipping to APC, APC covers ground freight transportation costs back to the customer. For Computer Interface Port Specifications, see the APC Website. Service Specifications If the UPS requires service, please do Not return it to the dealer! Follow these steps: 1. Use the Troubleshooting section of the Quick Reference Guide to eliminate common problems. 2. Verify that no circuit breakers are tripped. A tripped circuit breaker is the most common UPS problem! 3. If the problem persists, call customer service or visit the APC Internet Website (• Note the model number of the UPS, the serial number, and the date purchased. A technician will ask you to describe the problem and try to solve it over the phone, if possible. If this is not possible the technician will issue a Return Merchandise Authorization Number (RMA#). • If the UPS is under warranty, repairs are free. If not, there is a repair charge. 4. Pack the UPS in its original packaging. If the original packing is not available, ask customer service about obtaining a new set. • Pack the UPS properly to avoid damage in transit. Never use Styrofoam™ beads for packaging. Damage sustained in transit is not covered under warranty. • Include a letter with your name, RMA#, address, copy of the sales receipt, description of the trouble, your daytime phone number, and a check (if necessary). 5. Mark the RMA# on the outside of the package. 6. Return the UPS by insured, prepaid carrier to the address given to you by Customer Service. 1000 VA 1100 VA 1400 VA Acceptable input voltage 0 - 160 VAC Input voltage (on-line operation) 94-148 VAC Output voltage 106-127 VAC Input Over Current Protection Resettable circuit breaker Frequency limits (on-line operation) 47 - 63 Hz (autosensing) Transfer time 4 ms typical, blackout response time Maximum load 1000 VA 670 W 1100 VA 670 W 1400 VA 950 W On-battery output voltage 115 VAC On-battery frequency 50 or 60 Hz, ±0.1 Hz; unless synchronized to utility during brownout On-battery waveshape Stepped sine-wave Output Over Current Protection Overcurrent and short-circuit protected, latching shutdown on overload Battery type Spill proof, maintenance free, sealed lead-acid Typical battery life 3 to 6 years, depending on number of discharge cycles and ambient temperature Typical recharge time 2 to 5 hours from total discharge Operating temperature 0 to +40 °C (+32 to +104 °F) Storage temperature -15 to +45 °C (+5 to +113 °F) Operating / storage relative humidity 0 to 95%, non-condensing Operating elevation 0 to +3,000 m (0 to +10,000 ft) Storage elevation 0 to +15,000 m (0 to +50,000 ft) Audible noise at 1 m (3 ft) <45 dBA Size (H x W x D) 21.6 x 17.0 x 43.9 cm (8.5 x 6.7 x 17.3 in.) Weight - net (shipping) 19.3 (21.1) kg 42.5 (46.5) lb. 19.3 (21.2) kg 42.5 (46.8) lb. 24.1 (25.9) kg 53.0 (57.0) lb. Listing, Certifications and Unlisted Components UL 1778, UL 497A, CSA 107.1, FCC part 15 EMI certification FCC/DOC Class B certified Electromagnetic immunity IEC 801-4 level IV, 801-5 level III APC Contact Information USA/Canada ………….. 1-800-800-4272 Mexico ………………….. ...

Ce manuel est également adapté pour les modèles :
Alimentation et alimentation - 1000, 1100, 1400 (180.98 kb)
Alimentation et alimentation - 1400 (180.98 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories