Instructions Emerson, Modèle PowerSure PA350-120U

Fabricant : Emerson
Taille : 256.38 kb
Nom Fichier : SL-23275QS-R09-03.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


(3000 m) at 86°F(30°C) w/oderating Audible Noise < 40 dBA, at 1 meter AGENCY Safety UL 1778, c-UL Listed Surge ANSI C62.41, Category A, Level 3, (IEEE 587, Category A); EN61000-4-5, Level 3, Criteria A ESD EN61000-4-2, Level 3, Criteria A Susceptibility EN61000-4-3, Level 2, Criteria A Electrical Fast Transient/Burst EN61000-4-4, Level 3, Criteria A Emissions FCC Part 15, Subpart B, Class B Harmonics EN61000-3-2 Conducted Immunity EN61000-4-6 Flicker EN61000-3-3 Transportation ISTA Procedure 1A COMMUNICATIONS The PowerSure PST has a USB interface port for communication that will work with the built-in Microsoft Power Manager software on the user’s PC, if the PC is so equipped. It will provide UPS status and manages the automatic, orderly shutdown of the computer. The UPS (USB) communications meets HID standard, version 1.11. All USB models are compatible with Microsoft Windows 2000, Windows XP and Mac OS 10.2 or later. All USB models ship with a 6 ft. (1.8m) USB cable. TROUBLESHOOTING TROUBLESHOOTING CHART The information below indicates various symptoms a user may encounter in the event the PowerSure PST experiences a problem. Use this information to determine whether external factors caused the problem. See Troubleshooting Chart for suggested remedy. 1. The Fault indicator 2. An alarm sounds, alerting that the illuminates, indicating the UPS requires attention. The alarm UPS detected a problem. can be silenced except for low battery, overload and overtemperature warning conditions. 3. Utility and/or Battery indicators may be illuminated as a diagnostic aid to the operator, as shown Fault Utility/Battery Indicator Indicator below: Site Wiring Fault Indicator GUIDE TO STATUS INDICATORS Fault (Red) ! Site WiringFault (Amber) Utility/Battery(Green) + - Diagnosis/ Audible Alarm Normal Mode — — ON UPS is operating in Normal Mode; no beep. — — Flashing Battery Test has been initiated; no beep. — Flashing ON Site WiringFault; no beep. Flashing — ON The unit is overloaded; beep every half-second ON — ON The UPS has failed; continuous beep Flashing — — Unit has shut down due to overload; continuous beep ON — — The UPS shut down due to failure; continuous beep Battery Mode — — Flashing The UPS is operating in Battery mode; beep every 5seconds. — — Flashing UPS battery is low; beep every half-second Flashing — Flashing The unit is overloaded; beep every half-second ON — Flashing The UPS has failed; continuous beep MAINTENANCE The PowerSure PST UPS requires very little maintenance. Follow these practices to prevent problems. CLEANING THE UPS The following will help ensure trouble-free operation for years: • Vacuum dust from the ventilation intake occasionally. • Wipe the cover periodically with a dry cloth. MAINTAINING BATTERIES The batteries are valve-regulated, nonspillable, lead acid and must be kept charged to retain their design life. The UPS continuously charges the batteries when connected to the utility supply, even while the UPS is switched off. When storing the UPS, it is recommended to pl...

Ce manuel est également adapté pour les modèles :
Alimentation et alimentation - PowerSure 350-500VA (256.38 kb)
Alimentation et alimentation - PowerSure PA500-120U (256.38 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories