Log:
Évaluations - 2, GPA: 4 ( )

Instructions Creda, Modèle EUROPA S230G

Fabricant : Creda
Taille : 178.21 kb
Nom Fichier : S230E.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


LOCATION The appliance may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room containing a bath or shower. The appliance must not be installed in a bed-sitting room of less than 20m3. PROVISION FOR VENTILATION The room containing the appliance should have an air supply in accordance with BS 5440: Part 2. The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room has a volume between 5 and 10m3, it will require an air vent of 50cm2 effective area unless it has a door which opens directly to outside. If the room has a volume of less than 5m3, it will require permanent air vent of 100cm2 effective area. If there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent requirements. TECHNICAL DATA Gas connection Rp 1/2 (1/2" BSP female) Gas supply G20 at 20 mbar. Pressure test point Grill injector Electrical connection Flexible cord fitted with a 3 pin 13 amp plug. 230 - 240 a.c. 50HZ 3A fuse BURNER HEAT INPUT INJECTOR Grill 3.4 kW 150 Main Oven 2.4 kW 110 Top Oven 1.65 kW 095 INSTALLATION 1. GENERAL The appliance is designed for mounting at a safe level into an oven housing which must be secured to the backing wall. 2. VENTILATION a. The oven housing unit cabinet dimensions must comply with fig. 4. b. An air gap of 30mm minimum must be provided at the rear of any top or bottom cupboards or shelves (see fig. 1). c. It is necessary that the cabinets are provided with unobstructed ventilation, i.e. from adjacent cabinetry. This can be done by either raising the base of the cabinets using the adjusting feet (or spacers) or alternatively by providing a slot in the cabinet plinth to the dimensions in fig. 1. d. The air gap at rear allows the warmed air to pass out of the inner cabinet space. Where it is intended to fit cupboards above the oven unit to ceiling height, it is essential that the warmed air is exhausted through the front of the cabinet (see fig. 1). e. If an oven unit is installed adjacent to a tall cabinet, steam escaping from the oven when the door is opened could condense on and maybe stain the adjacent surface. To prevent permanent staining, the adjacent surface should be made of a material that is heat resisting and easy to clean. Adjacent tall cabinets should not be deeper than the oven housing cabinet. 3. FINAL INSTALLATION a. Using a spirit level, check that the housing cabinet is level from side to side and from front to back in its installed position. b. Correct any unevenness by placing spacers under the bottom of the cabinet. Make sure that the cabinet rests firmly on the floor without rocking. c. Before the oven is fitted, the cabinet must be firmly secured to the backing wall for stability. d. The oven unit should now be lifted (this is a two person lift) into the cabinet and pushed fully home. e. Finally, the oven is secured to the cabinet by means of the four Pozi Wash Head screws - two through each side trim. f. Remove all packaging material from the grill and oven interior. LIST OF LOOSE ITEMS 4 x Pozi Wash Head No. 6 x 15mm screws. Note: This appliance must not be installed over any other appliance that generates heat. TALL CABINET VENTILATION Figure. 1 Ventilation Slot required here if cabinet does not fit to ceiling -50mm x 450mm min. area 30mm Air Gap 30mm Air Gap Ventilation Slot required here if the cabinet does fit to the ceiling 50mm x 450mm min. area Ventilation Slot required here 50mm x 450mm min. area 29 577mmexc.handleknobs 565 887mm 597mm 560mm 560-574mm 875mm 887mm 878mm if cooker trim is to overlap top edge of shelf * excluding pipe work and other projections Fig. 4 Fig. 2 550mm 565mmmin * 560mm Viewed down through cabinet No. 6 x 15mm screw (4 supplied) Cabinet 577mmexc.handleknobs 565 887mm 597mm 560mm 560-574mm 875mm 887mm 878mm if cooker trim is to overlap top edge of shelf * excluding pipe work and other projections Fig. 4 Fig. 2 550mm 565mmmin * 560mm Viewed down through cabinet No. 6 x 15mm screw (4 supplied) Cabinet Oven Door Fig. 3 The appliance can be installed into a cabinet of minimum depth 550mm providing a suitable means of connection to the gas supply can be made. INSTALLATION INSTRUCTIONS CONNECTING TO GAS SUPPLY The oven is designed to be connected with an approved appliance flexible connection to BS 669. A length of 1.25 to 1.55m is recommended. An adaptor backplate should be fitted in the area shown to allow the appliance to be pushed fully back into the cabinet. The flexible hose should be fitted such that it cannot come into contact with moveable parts of the housing unit (e.g. a drawer) and does not pass through a space where it is likely to become trapped or damaged. The temperature rise of areas at the rear of the appliance that are likely to come in contact with the flexible hose do not exceed 70oC. 200mm 630mm 450mm 50mm CABINETS LESS THAN 565mm DEEP The appliance can be fitted into a cabinet of minimum depth 550mm ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories