Log:
Évaluations - 4, GPA: 3 ( )

Instructions APW Wyott, Modèle KLT-12G

Fabricant : APW Wyott
Taille : 441.35 kb
Nom Fichier : KLT-12G-man.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment. PURCHASER: Instructions to be followed in the event that the operator of this appliance smells gas must be posted in a prominent location. This information shall be obtained by consulting the local gas supplier. Do not obstruct the flow of combustion and ventilation air. Keep the appliance area free and clear from combustibles. Adequate clearances must be maintained for servicing and proper operation. Do not attempt to operate this unit in the event of a power failure. Intended for commercial use only. Not for household use. This manual should be retained for future reference. TABLE OF CONTENTS DESCRIPTION PAGE 1.0 IMPORTANT NOTES FOR INSTALLATION AND OPERATION .......................... 2 2.0 SERVICE CONNECTIONS ................................................................................. 4 3.0 INTRODUCTION ................................................................................................. 5 4.0 INSTALLATION INSTRUCTIONS ........................................................................ 6 5.0 OPERATING INSTRUCTIONS ............................................................................ 9 6.0 PERIODIC MAINTENANCE .............................................................................. 11 7.0 TROUBLESHOOTING ...................................................................................... 14 APPENDIX A Material Safety Data Sheet ..................................................................... 15 2.0 SERVICE CONNECTIONS 3 [76] 4.75 [121] 23.75 [603] 25.388 [645] 17.25 [438] 5.5 [140] 11.25 [286] 15 [381] 7.75 [197] MIN. 6 [152] 12.50 [317] POUR PATH6 [152] 23.88 [607] 32.88 [835] 55.75 [ 1416] 30 [762] O16.75 [425] I.D. O20 [508] 15.88 [ 403] FLANGED FOOT DETAIL47/16" [11mm] HOLESON 3 [76] B.C. EQUALLY SPACEDODIMENSIONS ARE IN INCHES [MM] SERVICE CONNECTIONSMODELKLT-12G43,000BTU/HR.kW/HR. 12.6Unless otherwise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hz. single phase with grounding wire. Unit furnished with 6' cord and 3 prong plug. Total max. amps 2.0. GAS CONNECTION: Supply gas through 3/4" pipe. NATURAL 6" - 14" W.C. (152mm - 355mm W.C.) PROPANE 12" - 14" W.C. (305mm - 355mm W.C.) Contact manufacturer for installation over 2,000 ft. elevation. 3.0 INTRODUCTION DESCRIPTION Model KLT-12G (12 gallon capacity) gas fired, self-contained, tilting kettle. The kettle has a jacket of double-wall construction forming a sealed reservoir around the lower two-thirds of the kettle. The reservoir is charged with distilled water. The kettle is equipped with a “clean lock” to hold kettle in cooking position or tilted 105 degrees for ease of cleaning. The kettle is also equipped with automatic ignition, low water cut off and tilt switch, which, when activated, shuts down the burner. BASIC FUNCTION The kettle operates by generating steam in the kettle reservoir. The sequence of operation is as follows: 1. Operator turns the power switch to the on position and sets the temperature control dial to the desired setting. 2. The red light comes on indicating the kettle is heating. The green “IGNITION” light comes on indicating that the ignition and burner are active. 3. Once the kettle reaches the set temperature, the red “TEMPERATURE” light and the green “IGNITION” light extinguish. 4. All kettles are supplied with sufficient water in the jacket. If for any reason the water level falls below the required amount to operate the kettle, the burner shuts down and the amber light comes on. See Adding Water in Service section. 5. The sight glass indicates the water level within the kettle jacket. 6. The relief valve is a safety feature which prevents the internal kettle pressure from exceeding 50 PSI. It should never be tampered with. 4.0 INSTALLATION INSTRUCTIONS GENERAL Gas installation to conform to local codes or in absence of local codes to the National Fuel Gas Code - ANSI Z223.1 - latest edition. In Canada, installation to be according to CAN/CGA- B149.1 (NAT) or CAN/CGA-B149.2 (LP) installation codes as applicable. 1. The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than . psig (3.45 Kpa). 2. The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures eq...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories