3. On/Off Light is OFF: No power .. System is turned off. .. Turn Control Knob clockwise to the desired setting. .. Main fuse blew. .. Check main fuse on bottom of Control Box and replace if necessary with a 6.3 Amp 250VAC 6x32mm Slow Blow fuse. One extra fuse is supplied on the bottom-side of the Control Box cover. .. Breaker jumped .. Check the breaker leading to the pool control. .. Power wires cut, disconnected, or incorrectly wired. .. Check for correct wiring. .. Other malfunction in Control Box. .. Contact warranty hotline. 4. On/Off Light is Solid Green .. System is on. This is normal. 5. Red Flow Light is Off .. This is normal. 6. Flow Light is Turning On and Off .. This is normal at initial start- up or if air bubbles are in pipes. .. Wait a few minutes for air to clear. If continuous, see troubleshooting section “Flow Light is Solid Red” below. 7. Flow Light is Solid Red .. Insufficient water flow from pump to Flow Sensor and Cell. .. This is normal for a few minutes at initial startup or if air is in the lines. .. Clean filters and strainers. .. Check for closed valves, faulty pump, etc. .. Obstruction or scale buildup in Cell. .. Clean Cell according to instruction manual. (See “Maintenance” section) .. Flow Sensor was not installed in the correct direction. .. Turn Flow Sensor so arrow faces direction of water flow. .. Flow Sensor is not fully threaded into the “T” connector. .. Fully thread the Flow Sensor into the T connector being careful not to damage the wires or sensors. .. Cut wires or insufficient wire connections. .. Check the connection to ensure proper wire contact. 8. Power Meter lights do not reach 100% .. Control Knob set too low .. Turn Control Knob higher (clockwise). .. If the red light above the Power Meter illuminates or if the lights go up and down, see Troubleshooting Section “Salinity High” below. .. Dirty Cell, Loose Connection, or Salinity Low. .. See Troubleshooting Section “Salinity Low” below. TROUBLESHOOTING Note: evaluating the possible causes for each problem from top to bottom (first to last) will avoid extra labor. PROBLEM POSSIBLE CAUSES WHAT TO DO 9. Salinity Low .. Dirty Cell .. Check the Cell to ensure the blades are in good condition and not coated with calcium buildup. Cleaning the Cell is recommended if it is calcified or if the readout seems questionable. (See “Cell Cleaning” under the “Maintenance” section). .. Loose connection with the Cell’s connection pegs. .. Ensure the connectors are pushed completely over the pegs and tighten connections with a screwdriver. .. Not enough salt due to heavy rain, initial miscalculation, etc. .. Add salt into the pool. See the “Adding The Salt” section for more information. .. It is also recommended to periodically test the salt level by a professional and adjust according to the “Salinity Demand Table” in this manual. .. Worn Cell .. If none of the above resolutions worked, the cell may be worn out. 10. Salinity High .. Salinity High. Enough salt has been added causing the red light above the power meter to light. .. This does no harm to the Natural Generator, but simply indicates that the salt level is on the high side for your information. Slowly turn down the Control Knob (counterclockwise) until the desired Power Meter light illuminates. .. It is also recommended to periodically test the salt level by a professional. If above 5500 ppm, it is recommended to drain part of the pool water and refill with fresh water. (Please check with your local pool professional prior to draining the pool) .. Salinity is very high. Too much salt has been added causing the Power Meter Lights to go up quickly, and then shut down. .. The salt level is very high. Drain part of the water and refill the pool to bring the salinity down. .. It is also recommended to periodically test the salt level by a professional. If above 5500 ppm, it is recommended to drain part of the pool water and refill with fresh water. (Please check with your local pool professional prior to draining the pool) .. Salinity far too high. Way too much salt has been added causing the Power Meter to completely shut down. .. The salt level is exceedingly high. Drain part of the water and refill the pool to bring the salinity down. .. It is also recommended to periodically test the salt level by a professional. If above 5500 ppm, it is recommended to drain part of the pool water and refill with fresh water. (Please check with your local pool professional prior to draining the pool) 11. RED light at the top of the Power Meter is lit .. Salinity high .. See Troubleshooting Section “Salinity High” above. 12. Lights go up & down quickly .. Salinity is very high. .. Drain part of the water and refill the pool to bring the salinity down. See Troubleshooting Section “Salinity High” above for more information. .. It is also recommended to periodically test the salt level by a professional. If above 5500 ppm, it is recommended to drain part of the pool water and refill with fr...
Ce manuel est également adapté pour les modèles :Electricité - Auto-Chlor AC-4000 (2.75 mb)
Electricité - Auto-Chlor AC-6000 (2.75 mb)
Electricité - CC-350 (2.75 mb)