reserves the right to make product changes or improvements at any time without notification. Optional Remote Alarm Panel Catalog No. 6000.43B Effective: 12-28-07 Replaces: 12-15-99 System Characteristics Control Solid State Electronic Circuit Board Front Panel Indicator Lights Power - Green Pilot - Amber Main Gas - Green Safety Shutdown - Red Auxiliary Alarm - Red Alarms Mechanical Alarm Bell (3" Standard/4" Option) Electronic Alarm Buzzer Auxiliary Alarm Option: Adjustable Time Delay: 5 - 60 secs. Momentary Alarm Silencing Switch Remote Alarm Panel (Optional) Electric Alarm Buzzer and Indicating Light Remote Alarm Silencing Switch Mounts with 4" X 4" Duplex Box Mountable up to 500' Away Sample Specification Electrical Characteristics Power: 120 VAC, 0.25A, 60 Hz Monitors: 24 or 120 VAC Ambient Conditions Temperature: -40 to 175°F Humidity: Non-condensing to 90% RH Interoperability Integrates with all Raypak Boilers and Controls Enclosure NEMA 3R Rainproof 8-1/2W x 10H x 7D Gasketless Door Vandal Resistant Design Left, Right or Rear Mounting Boiler or Remote Mounted Limited One Year Warranty C Provide the Raypak UL Listed E-4 Swimming Pool Alarm that shall monitor and give indication of an alarm condition affecting its associated Swimming Pool Heater. The alarm module shall be solid state and shall be capable of processing either 24 VAC or 120 VAC inputs. It shall be equipped with LED's (Light emitting diodes)that indicate a signal present and shall be color coded as listed below: Power Pilot Main Gas Safety Shutdown Auxiliary Alarm Green: indicating the alarm unit is receiving power. Amber: indicating the pilot gas valve is open. Green: indicating the main gas valve is open. Red: indicating that a safety shutdown has occurred. Red: (Optional Aux. Alarm) indicating that a safety shutdown has occurred after a built-in user adjustable time delay has expired. A 3" diameter and 4" diameter mechanical bell and a modulating electronic alarm buzzer shall sound when an alarm condition occurs. A momentary switch shall silence the alarm bell and buzzer. The alarm signal will automatically reset once the alarm condition has been corrected. Provide a remote alarm panel with indicating light, electronic alarm buzzer and remote silencing switch. The remote alarm panel shall mount in a 4" X 4" junction box up to 500 feet away from the alarm control panel. The alarm module shall be suitable for wall or heater mounting up to 20 feet away from the associated heater and shall be enclosed in a NEMA 3R rated rainproof enclosure. The enclosure shall be vandal resistant and shall be of a gasketless mechanical seal design. The alarm and heater shall be manufactured by the same company and shall carry single source responsibility. Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX: (800) 872-9725 Litho in U.S.A....