Facilité d'utilisation
Replace ignitor cable5. Bad piezo ignitor5. Replace piezo ignitor 6. Ignitor electrode broken6. Replace pilot assembly7. Ignitor electrode positioned wrong 7. Replace pilot assembly When ignitor button is pressed, 1. Gas supply turned off or equip1. Turn on gas supply or open there is spark at ODS/pilot but ment shutoff valve closed equipment shutoff valveno ignition 2. Control knob not in PILOT 2. Turn control knob to PILOT positionposition3. Control knob not pressed in 3. Press in control knob while in while in PILOT positionPILOT position4. Air in gas lines when in4. Continue holding down con- stalled trol knob. Repeat igniting operation until air is removed 5. Depleted gas supply (propane/5. Contact local propane/LP gas LP only)company6. ODS/pilot is clogged 6. Clean ODS/pilot (see Cleaning and Maintenance, page 23) orreplace ODS/pilot assembly7. Gas regulator setting is not 7. Replace gas regulator correct ODS/pilot lights but flame 1. Control knob not fully pressed in1. Press in control knob fullygoes out when control knob is 2. Control knob not pressed in 2. AfterODS/pilotlights,keepconreleased long enoughtrol knob pressed in 30 seconds3. Equipment shutoff valve not 3. Fully open equipment shutoff fully openvalve 4. Pilot flame not touching ther4. A) Contact local propane/LPmocouple, which allows theror natural gas companymocouple to cool, causing pilot flame to go out. This B) Clean ODS/pilot (see problem could be caused by Cleaning and Maintenance, one or both of the following:page 23) or replace ODS/pilot A) Low gas pressureassemblyB) Dirty or partially clogged ODS/pilot5. Thermocouple connection 5. Hand tighten until snug, then loose at control valve tighten 1/4 turn more6. Thermocouple damaged6. Replace pilot assembly7. Control valve damaged 7. Replace control valve 113097-01D TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does light after ODS/ 1. Burner orifice clogged 1. Clean burner (see Cleaning pilot is lit and Maintenance, page 23) or replace burner orifice 2. Inlet gas pressure is too low 2. Contact local propane/LP or natural gas company Delayed ignition of burner 1. Manifold pressure is too low 1. Contact local propane/LP or natural gas company 2. Burner orifice clogged 2. Clean burner (see Cleaning and Maintenance, page 23) or replace burner orifice Burner backfiring during 1. Burner orifice is clogged or 1. Clean burner (see Cleaning combustion damaged and Maintenance, page 23) or replace burner orifice 2. Damaged burner 2. Replace damaged burner 3. Gas regulator defective 3. Replace gas regulator Slight smoke or odor during 1. Not enough air 1. Check burner for dirt and de- initial operation bris. If found, clean burner (see Cleaning and Maintenance, page 23) 2. Gas regulator defective 2. Replace gas regulator 3. Residues from manufacturing 3. Problem will stop after a few processes and logs curing hours of operation Moisture/condensation noticed on windows Heater produces a whistling noise when burner is lit 1. Not enough combustion/ventilation air 1. Turning control knob to HI or position 5 when burner is cold 2. Air in gas line 3. Air passageways on heater blocked 4. Dirty or partially clogged burner orifice 1. Refer to Air for Combustion and Ventilation requirements (page 5) 1. Turn control knob to LO or position 1 and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local propane/ LP or natural gas company 3. Observe minimum installation clearances (see page 9) 4. Clean burner (see Cleaning and Maintenance, page 23) or replace burner orifice White powder residue forming 1. When heated, vapors from 1. Turn heater off when using withinburnerboxoronadjacent furniture polish, wax, carpet furniture polish, wax, carpet walls or furniture cleaners, etc. may turn into cleaners or similar products white powder residue Heater produces a clicking/tick-1. Metalexpandingwhileheating 1. Thisiscommonwithmostheating noise just after burner is lit orcontractingwhilecooling ers.Ifnoiseisexcessive,contact or shut off qualified service person 113097-01D TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heater produces unwanted 1. Heater burning vapors from 1. Open window and ventilate odors paint, hair spray, glues, clean-room. Stop using odor causers, chemicals,...
Ce manuel est également adapté pour les modèles :électrique - CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB (1.98 mb)