Fig. 40 — Disconnect Location — Size 070-100 Units 36 TB1 21 11 22 12 2313DISCONNECT PER NEC EQUIP GND LEGEND EQUIP — Equipment GND — Ground NEC — National Electrical Code TB — Terminal Block Fig. 41 — Field Power Wiring Connections FACTORY-INSTALLED DISCONNECT HANDLE LOCATION FACTORY-INSTALLED DISCONNECT (HIDDEN) 23 13 12 11 22 21 DISCONNECT PER NEC FACTORY WIRE EQUIP GND FIELD WIRE LEGEND EQUIP — Equipment GND — Ground NEC — National Electrical Code Fig. 43 — Field Power Wiring Connections for Factory-Installed Disconnect Fig. 42 — Factory-Installed Disconnect Location (End of Unit Shown) 37 Table 10 — Electrical Data, 48P2,P3,P4,P5030 Units VOLTAGE 3 PH, 60 Hz VOLTAGE RANGE COMPRESSOR CONDENSER FAN MOTOR EVAPORATOR FAN MOTOR POWER EXHAUST POWER SUPPLY No. A1 No. B1 Min Max Qty RLA (ea) LRA (ea) Qty RLA (ea) LRA (ea) Qty FLA Hp FLA Qty Hp (ea) FLA (ea) MCA FUSE OR HACR BRKR* 208/230 187 253 1 51.3 300 1 51.3 300 2 6.6 (ea) 7 1/2 24.2 / 22.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0 152.8/150.6 174.0/169.8 186.2/181.0 201.2/194.6 214.4/206.6 200/200 225/200 225/225 250/225 250/250 10 30.8 / 28.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0 159.4/156.6 180.6/175.8 192.8/187.0 207.8/200.6 221.0/212.6 200/200 225/225 225/225 250/250 250/250 15 46.2 / 42.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0 174.8/170.6 196.0/189.8 208.2/201.0 223.2/214.6 236.4/226.6 225/200 225/225 250/250 250/250 250/250 20 59.4 / 54.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0 190.1/183.3 211.3/202.5 223.5/213.7 238.5/227.3 251.7/239.3 225/225 250/250 250/250 250/250 300/250 25 74.8 / 68.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0 209.3/200.8 230.5/220.0 242.7/231.2 257.7/244.8 270.9/256.8 250/250 300/250 300/250 300/300 300/300 30 88.0 / 80.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0 225.8/215.8 247.0/235.0 259.2/246.2 274.2/259.8 287.4/271.8 300/250 300/300 300/300 350/300 350/350 460 414 508 1 23.1 150 1 23.1 150 2 3.3 (ea) 7 1/2 11.0 — 2 2 2 2 — 3 5 7.5 10 — 4.8 7.6 11.0 14.0 69.6 79.2 84.8 91.6 97.6 90 100 100 110 110 10 14.0 — 2 2 2 2 — 3 5 7.5 10 — 4.8 7.6 11.0 14.0 72.6 82.2 87.8 94.6 100.6 90 100 110 110 110 15 21.0 — 2 2 2 2 — 3 5 7.5 10 — 4.8 7.6 11.0 14.0 79.6 89.2 94.8 101.6 107.6 100 110 110 110 125 20 27.0 — 2 2 2 2 — 3 5 7.5 10 — 4.8 7.6 11.0 14.0 86.6 96.2 101.8 108.6 114.6 110 110 125 125 125 25 34.0 — 2 2 2 2 — 3 5 7.5 10 — 4.8 7.6 11.0 14.0 95.3 104.9 110.5 117.3 123.3 125 125 125 150 150 30 40.0 — 2 2 2 2 — 3 5 7.5 10 — 4.8 7.6 11.0 14.0 102.8 112.4 118.0 124.8 130.8 125 150 150 150 150 38 Table 10 — Electrical Data, 48P2,P3,P4,P5030 Units (cont) VOLTAGE 3 PH, 60 Hz VOLTAGE RANGE COMPRESSOR CONDENSER FAN MOTOR EVAPORATOR FAN MOTOR POWER EXHAUST POWER SUPPLY No. A1 No. B1 Min Max Qty RLA (ea) LRA (ea) Qty RLA (ea) LRA (ea) Qty FLA Hp FLA Qty Hp (ea) FLA (ea) MCA FUSE OR HACR BRKR* 575 518 632 1 19.9 109 1 19.9 109 2 2.6 (ea) 7 1/2 9.0 — 2 2 2 2 — 3 5 7.5 10 — 3.9 6.1 9.0 11.0 59.0 66.8 71.2 77.0 81.0 70 80 90 90 100 10 11.0 — 2 2 2 2 — 3 5 7.5 10 — 3.9 6.1 9.0 11.0 61.0 68.8 73.2 79.0 83.0 80 80 90 90 100 15 17.0 — 2 2 2 2 — 3 5 7.5 10 — 3.9 6.1 9.0 11.0 67.0 74.8 79.2 85.0 89.0 80 90 90 100 100 20 22.0 — 2 2 2 2 — 3 5 7.5 10 — 3.9 6.1 9.0 11.0 72.5 80.3 84.7 90.5 94.5 90 100 100 110 110 25 27.0 — 2 2 2 2 — 3 5 7.5 10 — 3.9 6.1 9.0 11.0 78.8 86.6 91.0 96.8 100.8 100 110 110 110 125 30 32.0 — 2 2 2 2 — 3 5 7.5 10 — 3.9 6.1 9.0 11.0 85.0 92.8 97.2 103.0 107.0 110 110 125 125 125 LEGEND NOTE: Units use 1 (low heat) or 2 (high heat) combustion fan motors rated at 0.3 FLA each. FLA — Full Load Amps HACR — Heating, Air Conditioning, and Refrigeration Hp — Nominal Horsepower LRA — Locked Rotor Amps MCA — Minimum Circuit Amps (for wire sizing) RLA — Rated Load Amps * Used to determine minimum disconnect per NEC (National Electrical Code). 39 Table 11 — Electrical Data, 48P2,P3,P4,P5035 Units VOLTAGE 3 PH, 60 Hz VOLTAGE RANGE COMPRESSOR CONDENSER FAN MOTOR EVAPORATOR FAN MOTOR POWER EXHAUST POWER SUPPLY No. A1 No. B1 Min Max Qty RLA (ea) LRA (ea) Qty RLA (ea) LRA (ea) Qty FLA Hp FLA Qty Hp (ea) FLA (ea) MCA FUSE OR HACR BRKR* 208/230 187 253 1 55.8 340 1 55.8 340 2 6.6 (ea) 7 1/2 24.2 / 22.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0 163.0/160.8 184.2/180.0 196.4/191.2 211.4/204.8 224.6/216.8 200/200 225/225 250/225 250/250 250/250 10 30.8 / 28.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0 169.6/166.8 190.8/186.0 203.0/197.2 218.0/210.8 231.2/222.8 225/200 225/225 250/250 250/250 250/250 15 46.2 / 42.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0 185.0/180.8 206.2/200.0 218.4/211.2 233.4/224.8 246.6/236.8 225/225 250/250 250/250 250/250 300/250 20 59.4 / 54.0 — 2 2 2 2 — 3 5 7.5 10 — / — 10.6 / 9.6 16.7 / 15.2 24.2 / 22.0 30.8 / 28.0...

Ce manuel est également adapté pour les modèles :
électrique - WEATHER MASTER 48P2 (5.33 mb)
électrique - WEATHER MASTER P3 (5.33 mb)
électrique - WEATHER MASTER P5030-100 (5.33 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories