Log:
Évaluations - 2, GPA: 3 ( )

Instructions State Industries, Modèle GPV85 650 NEA

Fabricant : State Industries
Taille : 960.88 kb
Nom Fichier :
Langue d'enseignement:
Aller à la télécharger



Facilité d'utilisation


Professional start-up service is also available from State on these Titan units to help ensure optimum performance. Powered Gas Low-NOx Burner (Natural Gas Only) • Premix burner operation includes internal Flue Gas Recirculation (FGR) • Safety features: Internal blocked flue sensor, separate pilot system, internal thermal cutoff and anti-flashback barrier Three Venting Options • Conventional atmospheric vertical venting on GPG models, with barometric draft regulating damper. Order Vent Kit Part # 170777-005 • Horizontal atmospheric sidewall venting or direct venting on GPV models • For sidewall venting order Vent Kit Part # 192049-000 • For direct-venting order Vent Kit Part # 192050-002 Automatic Controls • Safety shut-off, high-temperature limit control • Dual thermostat for accurate temperature adjustment from 120.F to 180.F Patented “Dome Design” Combustion • Draft-equalizing dome balances pressure inside combustion chamber for optimum flue loading and efficient heat transfer Adjustable Damper for High-Altitude Installations • Air intake damper easily reset for high-altitude installation by authorized start-up agent ASME Tank Construction – Rated Working Pressure 160 psi Factory-Installed AGA/ASME Temperature and Pressure Relief Valve Glass-Lined Tank • With multiple anode rods for long-term protection against corrosion Flame Inspection Port Handhole Cleanout • For easy removal of sediment from tank bottom Meets ASHRAE/IESNA 90.1-1999 Requirements • Also meets SCAQMD low-NOx Rule 1146.2 Three-Year Limited Tank Warranty • For complete warranty information, consult written warranty shipped with water heater, or contact State Water Heaters For Additional Technical Information, PHONE 800-365-0024 STATE WATER HEATERS 500 Tennessee Waltz Parkway, Ashland City, TN 37015 Page 1 of 2 SCGSS00205 March 2007R ™ POWERED TITAN BURNER Low-NOx Commercial Gas Water Heaters CAPACITY, INPUT AND OUTPUT MODELNUMBERGPG85 540 NEAGPV85 540 NEAGPG85 650 NEAGPV85 650 NEAGPG85 740 NEAGPV85 740 NEAFIRSTHOURRATING100° FRISE5832206.76902611.77782944.7TANKSIZE85321.785321.785321.7BTU INPUT PER HOUR540,000650,000740,000GallonsorLitresU.S. GallonsLitresU.S. GallonsLitresU.S. GallonsLitresGPHorLPHGPHLPHGPHLPHGPHLPH40°F4°C13094954.615795976.517946790.3100°F56°C5231979.66302384.67182717.6140°F78°C3741415.64501703.35121937.9RECOVERY-GALLONS PER HOUR AT °F TEMPERATURE RISE Based on 80% Thermal Efficiency obtained in State engineering laboratories. To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 5% for every 1,000 feet above sea level. Current Draw (120V, 60Hz, 1 Phase): 6.0 Amps DIMENSIONS AND WEIGHT –...

Ce manuel est également adapté pour les modèles :
électrique - GPG85 540 NEA (960.88 kb)
électrique - GPG85 650 NEA (960.88 kb)
électrique - GPV85 540 NEA (960.88 kb)
électrique - GPV85 740 NEA (960.88 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories