|
Facilité d'utilisation
These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada. Qualified Installing Agency Installationandreplacementofgaspiping,gasutilizationequipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction. Any alteration of the original design, installed other than as shownintheseinstructionsorusewithatypeofgasnotshownon the rating plate is the responsibility of the person and company making the change. Important All correspondence should refer to complete Model Number, Serial Number and type of gas. High Altitude When installing this unit at an elevation above 2000 feet (in the United States) it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Generally, input should be reduced 4 percent for each 1000 feet above sea level. However, if the heating value of the gas has been reduced, this general rule may not apply. Check with local gas utility for proper orifice size identification. Canadian High Altitude Altitude: 0-4500 feet (0-1370 m) Wheninstallingthisunitatanelevationabove4500feet(inCanada), check with local authorities. Consult your local gas utility for assistance in determining the proper orifice for location. Preparation This direct vent gas fireplace and its components are tested and safe when installed in accordance with this Installation Manual. Report to your dealer any parts damaged in shipment, specifically check glass condition. Do not install unit with damaged, incomplete, or substitute parts. Read all instructions before starting installation and follow these instructions carefully during installation to insure maximum benefit and safety. Failure to follow them will void your warranty and may present a fire hazard. The warranty will be voided by, and the warranter disclaims any responsibility for the following actions: • Installation of any damaged fireplace or vent system component. • Modification of the fireplace or direct vent system. • Installation other than as instructed by Empire Comfort Systems, Inc. • Improper positioning of the logs, glass door or decorative rock. • Installation and/or use of any component part not manufactured or approved by manufacturer. State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation Code, or CSA B149.1 in Canada.*Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10036. Warning: ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS. Improper installation or use of the fireplace can cause serious injury or death from fire, burns, explosions, or carbon monoxide poisoning. Page 6 23552-4-0408 SPECIFICATIONS DVD32 DVD36 DVD42 DVD48 Input BTU/Hr Maximum 18,000 20,000 25,000 28,000 BTU/Hr Minimum (millivolt only) 14,000 14,000 18,000 20,000 KWH (Maximum) 5.3 5.9 7.3 8.2 (Minimum) 4.1 4.1 5.3 5.9 NAT. Orifice Air Shutter Opening LP #46 (.081") P-254 1/16" (1.6 mm) 2.10 mm P-288 1/16" (1.6 mm) #42 (.0935") P-286 3/16"(4.8 mm) #39 (.0995") P-285 1/8" (3.2 mm) Orifice Air Shutter Opening Height without standoff Width Depth Gas Inlet Shutoff Valve (Pipe) #56 (.0465") P-287 1/4" (6.3 mm) 32 3/4" (832 mm) 34" (864 mm) 16 3/8" (416 mm) 1/2 NPT #55 (.052") P-182 5/16" (7.9 mm) 32 3/4"(832 mm) 37" (940 mm) 16 3/8" (416 mm) 1/2 NPT 1.45 mm P-208 5/16" (7.9 mm) 34 3/4"(883 mm) 43" (1092 mm) 16 3/8" (416 mm) 1/2 NPT #52 (.0635") P-185 5/16" (7.9 mm) 34 3/4"(883 mm) 49" (1245 mm) 16 3/8" (416 mm) 1/2NPT NOTE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for optimum performance. Remote Control Options & Accessories FRBC FRBTC FREC TMW TRW FWS-1 Description Millivolt Battery Remote ON/OFF Millivolt Battery Remote Thermostat Direct Ignition/Millivolt 120V ON/OFF Remote Millivolt Wireless Wall Thermostat Millivolt Reed Switch Wall Thermostat Direct Ignition/Millivolt Wall Switch Venting Options DVVK-4TSP (DVVK-4TS) DVVK-4TP (DVVK-4T) DVVK-4RP (DVVK-4R) DVVK-4VP (DVVK-4V) DVVK-4F DVVK-4RE DV822 Description Top vent kit (horizontal) - 4." to 6" (114.3 mm to 152 mm) wall thickness Top vent kit (horizontal) - 8" to 12" (203 mm to 305 mm) wall thickness Rear vent kit (horizontal) - 5" to 7" (127 mm to 178 mm) wall thickness Vertical vent kit Horizontal fle...
Ce manuel est également adapté pour les modèles :électrique - 1 (3.48 mb)
électrique - DVD32FP3 (3.48 mb)
électrique - 2 (3.48 mb)
électrique - DVD32FP3 (3.48 mb)