Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Rinnai, Modèle RHFE-559FTA-A-P

Fabricant : Rinnai
Taille : 45.94 kb
Nom Fichier : 43cfbf4c-21c2-4480-ae49-3611b549ed30.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


13 in (330 mm) W.C. High: 162.7 Rinnai EX22C (RHFE-559FTA) Safety Devices Venting Maximum Vent Length Wall Thickness and Flue Manifold Kits (the “A” vent kit is included with the appliance) Warranty Conversion Kit • Flame rod detects flame failure; results in auto shutdown to prevent escape of gas • Bi-metal switch, thermal fuse, and thermistor detect overheat condition; results in auto shutdown • 3 amp fuse protects against power surge; results in auto shutdown • Abnormal spark at time of ignition results in auto shutdown • Combustion fan purges any gas from the combustion chamber before ignition • Convection fan continues to run after burner shutdown to cool internal parts • Child lock prevents inadvertent operation • Appliance shuts down if room reaches 104° F (40° C) concentric; 3 1/8 inch (80 mm) wall hole 13 feet (4 m) with a maximum of 2 bends; maximum 10 feet (3 m) vertically Name Kit No. fits walls S Vent Kit F0T-150 3 - 4 1/2 in (75 - 115 mm) A Vent Kit FOT-151 4 1/2 - 9 1/2 in (115 - 240 mm) B Vent Kit FOT-152 9 1/2 - 15 3/4 in (240 - 400mm) C Vent Kit FOT-153 15 3/4 - 23 5/8 in (400 - 600 mm) D Vent Kit FOT-154 23 5/8 - 31 1/2 in (600 - 800 mm) Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years To natural gas: 204000036 To propane gas: 204000040 Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal co...

Ce manuel est également adapté pour les modèles :
électrique - RHFE-559FTA-A-N (45.94 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories