|
Facilité d'utilisation
The following procedures must be followed: 1. Set your room thermostat to the lowest temperature setting. (See Fig. 19.) ® 19 6 2. Close the external manual gas valve. (See Fig. 9.) 3. Turn off electrical supply to the furnace. (See Fig. 20.) 4. Remove main furnace door. (See Fig. 11.) 5. Turn switch on the gas valve to OFF position. (See Fig. 21 or 22.) For 352MAV and 355MAV 21 ONOFF or For 340MAV and 350MAV 22 6. Replace main furnace door. (See Fig. 16.) 7. If the furnace is being shut down because of a malfunction, call your dealer as soon as possible. CAUTION! Furnace is not to be installed, operated, and then turned off and left turned off in an unoccupied structure during winter. (See “Heading South for the Winter?” procedures in maintenance section on page 9.) Freeze damage to furnace would occur. PERFORMING ROUTINE MAINTENANCE NOTE: The qualified installer or agency must use only factory- authorized replacement parts, kits, and accessories when modifying this product. Installing and servicing of heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained and qualified service agency personnel. Observe safety precautions in this manual, on tags, and on labels attached to the furnace and other safety precautions that may apply. With proper maintenance and care, your furnace will operate economically and dependably. Instructions for basic maintenance are found on this and the following pages. However, before beginning maintenance, follow these safety precautions: WARNING! Turn off electrical power supply to your furnace before removing the main furnace door to service or perform maintenance. Failure to follow this warning could result in personal injury/death or property damage. CAUTION! Although special care has been taken to minimize sharp edges, be extremely careful when handling parts or reaching into the furnace. Failure to follow this caution woud result in minor personal injury. FILTERING OUT TROUBLE CAUTION! Never operate your furnace without the air filter in place. Doing so may damage the furnace blower motor. An accumulation of dust and lint on internal parts of your furnace can cause a loss of efficiency and would cause minor property or product damage. A dirty air filter will cause a loss of airflow in your duct system. When excessive loss of airflow occurs, the furnace may cycle on its safety controls. If this condition is left unattended, the furnace will eventually lock out. It is recommended that the furnace air filter be checked every 3 or 4 weeks and cleaned if necessary. If installed with factory-specified disposable media filter, check or replace filter before each heating and cooling season. Replace media filter at least once a year. The air filter is normally located in the blower compartment (See Fig. 3 or 4.) or in the factory-supplied filter cabinet attached to the side or bottom of the furnace casing. If air filter has been installed in another location, contact your dealer for instructions. To inspect, clean, and/or replace the air filter(s), follow these steps: 1. Turn off electrical supply to furnace. (See Fig. 20.) 2. Remove door/access panel • AIR FILTER(S) LOCATED IN BLOWER COMPARTMENT a. Remove main furnace door. (See Fig. 23.) b. Remove blower access panel. (See Fig. 24.) NOTE: It will be necessary to remove 2 screws • AIR FILTER LOCATED IN FILTER CABINET a. Remove filter cabinet door (See Fig. 25 and 26.) NOTE: It will be necessary to remove 1 thumbscrew 3. Remove air filter from furnace. • AIR FILTER LOCATED IN BLOWER COMPARTMENT BOTTOM: a. Slide filter retainer sideways until it is free of latch. (See Fig. 27.) b. Slide air filter out of furnace. (See Fig. 28.) • AIR FILTER(S) LOCATED IN BLOWER COMPARTMENT SIDE: a. Remove filter retainer from latch. (See Fig. 29.) b. Gently remove air filter and carefully turn the dirty side up (if dirty) to avoid spilling dirt from the filter. (See Fig. 30.) • AIR FILTER LOCATED IN FILTER CABINET: a. Slide air filter out of furnace. Keep dirty side up (if dirty) to avoid spilling dirt. (See Fig. 31 and 32.) 4. Inspect the filter. If torn, replace it. NOTE: If washable filter that was shipped with the furnace has been replaced by: a. Factory specified disposable media filter – Do not clean. If dirty, replace only with media filter having the same part number and size. Install with airflow 7 8 direction arrow pointing towards blower. b. Electronic air cleaner (EAC) – Refer to EAC owner’s Manual for maintenance information. 27 28 29 30 31 5. If washable filter, wash filter (if dirty) in sink, bathtub, or outside with a garden hose. Always use cold tap water. A mild liquid detergent may be used if necessary. Spray water through filter in the opposite direction of airflow. Allow fil...
Ce manuel est également adapté pour les modèles :électrique - 350MAV (267.51 kb)
électrique - 352MAV (267.51 kb)