|
Facilité d'utilisation
USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. Page 14 12822-2-0903 12822-2-0903 Page 15 PARTS VIEW RH-50C & RH-65C Page 16 12822-2-0903 Figure 4 Installing Optional Blower 1. Remove rear shield (2 screws) and bottom reflector (4 screws). (See Figure 1) 2. Align blower cushion with bottom assembly air discharge opening. Foil face side of blower cushion should be placed upward. 3. Align blower housing with blower cushion and use two, #10 x 1/2" (13mm )hex-head screws to attach blower housing to bottom assembly. (See Figure 2) 4. Save bottom reflector and rear shield (removed in Step 1) in the event the blower housing is removed from room heater. Attention! Bottom reflector and rear shield must be attached to bottom assembly whenever the blower housing is removed from the room heater and the room heater is in operation. 5. Remove switch box cover from the switch box by removing the #8 x 1/4" (6mm) hex-head screw. 6. There are two screw holes on the lower back of the combustion chamber. Use only the left screw hole for mounting. 7. With the switch box perpendicular to the combustion chamber, align the round clearance hole on the switch box with the left screw hole on the combustion chamber. (See Figure 3) 8. Attach switch box to the combustion chamber using the #10 x 1/2" (13mm) hex- head screw provided. 9. Attach switch box cover to the switch box by using the #8 x 1/4" (6mm) hex- head screw. (See Figure 4) Figure 1 Figure 2 Figure 3 FRB-3 For Vented Room Heaters Models RH-50-(1, 2, 4, 5, 6) RH-50C-1 RH-65-(1, 2, 4, 5, 6) RH-65C-1 OPTIONAL BLOWER INSTALLATION INSTRUCTIONS Attention: Wiring harness on blower is factory assembled and installed. If wiring harness becomes disassembled use the following steps to reassemble the wiring harness. 1. Attach (1) pin terminal from black (hot) wire, smooth insulation on cord set to (1) socket terminal on fan control assembly. 2. Attach (1) pin terminal from black (neutral) wire, ribbed insulation on cord set to (1) socket terminal from white (neutral) wire on motor. 3. Attach (1) pin terminal on fan control assembly to (1) socket terminal from black (hot) wire on motor. 4. Attach green ground wire beneath one of the #10 x 1/2" (13mm) screws on the blower housing. Fan Control The automatic fan control is located in the switch box. The switch box is attached to the front of the blower assembly. The switch box is adjacent to the combustion chamber. The fan control is a non-adjustable automatic type. The fan control will require between 5 and 10 minutes of main burner operation before the fan control "closes" and activates the blower. The blower will continue to run between 5 and 10 minutes after the main burner shuts off, before the fan control "opens" and deactivates the blower. Index Part No. No. Description 1 11727 Blower Housing and Chute Assembly 2 9120106 Fan Control Switch 3 RH-863 Switch Box 4 DV-807 Switch Box Cover 5 R-2091 Wire Assembly 6 642031 Blower Wheel 7 11728 Motor Mounting Plate 8 632016 Motor Cushion 9 R-2605 Motor 10 8720161 Strain Relief Bushing 11 R-2099 Cord Set 12 RH-138 Blower Cushion Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screws. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded. A 7/8" (22mm) hole is provided in the junction box for use with a conduit connector if local codes require this type of protection. Wiring Diagram If any of the original wire as supplied with the appliance must be replaced, it must be replaced with type 125°C wire or its equivalent. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Warning: Unplugging of blower accessory will not stop the heater from cycling. To shut heater off: 1. Turn temperature dial or thermostat to lowest setting. 2. Turn knob on gas control to "OFF", depressing slightly. Do not force. Cleaning The blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level increases, it indicates a dirty wheel. Complete removal of the wheel and scrubbing it with a brush under flowing water is recommended. Oiling The blower motor has an oil hole located on each end of the motor. Use #20 motor oil only. It is bes...
Ce manuel est également adapté pour les modèles :électrique - RH-50-6 (704.99 kb)
électrique - RH-50C-1 (704.99 kb)
électrique - RH-50C-1 (704.99 kb)
électrique - RH-65-6 (704.99 kb)