Log:
Évaluations - 4, GPA: 4.5 ( )

Instructions Cadet, Modèle CEH-005R

Fabricant : Cadet
Taille : 682.49 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Mounting with rod from ceiling or super-structure: (Figure 6) a. Remove the four factory installed bolts from the top of the unit and screw them into the threaded holes in the back. b. Install four 5/16-18 threaded rods in holes and secure in place using lock (jam) nuts. c. Attach the four mounting rods to the ceiling or overhead structure and anchor securely. 2. Mounting with optional bolt-on ceiling bracket (CEKM1): (Figure 2) a. Bolt mounting bracket on top of unit using the four factory installed bolts. b. Suspend the unit from ceiling or overhead structure using a 1/2 inch threaded rod or bolt, allowing a minimum 6 inches clearance from the ceiling. Using lock (jam) nut, anchor securely. 3. Mounting with optional wall hanger arm (CEKWM) and ceiling bracket (CEKM1): (See Parts List items #8 & #9) a. Bolt mounting bracket on top of unit using four factory installed bolts. b. Attach the wall hanger arm to wall using four 3/8 inch bolts or masonry fasteners. c. Suspend the unit from hanger arm using 1/2 inch bolt. Place the rubber washer provided between the mounting brackets. Vertical Discharge (See Figure 5 for minimum clearances) 1. Install four 5/16-18 threaded rods into the threaded holes in the back of the heater and secure in place using lock (jam) nuts (Figure 7). 2. Attach the four mounting rods to ceiling or overhead structure and anchor securely. NOTE: When mounting for vertical discharge, position unit so that access door opens away from nearest wall. This permits maximum access to wiring compartment (Figures 2 and 5). E H G F 5/16-18 Threaded MountingHoles BACK MOUNTING ROD DIMENSIONS UNIT KW ROD THREAD E F G H 5.0 5/16-18 6” 9.63” 4.04” 2.10” (15.2 CM) (24.5 CM) (10.3 CM) (5.3 CM) Figure 7 Vertical discharge rod spacing WARNING! Risk of Electrical Shock. Turn off all power at the electrical panel board supplying power to the heater before doing any electrical wiring. A C FRONT 5/16-18Threaded MountingHoles D B MOUNTING ROD DIMENSIONS UNIT KW 5.0 ROD THREAD 5/16-18 A 6” (15.2CM) B 6.75” C 4.04” D 0.75” MAXIMUM MOUNTING HEIGHT (TO BOTTOM OF UNIT) MODEL HORIZONTAL DISCHARGE VERTICAL DISCHARGE CEH005 9’ 10’ Figure 8 WARNING! Overheating or fire may occur. DO NOT place the heater behind doors. Figure 6 Horizontal discharge rod spacing Wiring Instructions CAUTION: TO AVOID ELECTRICAL SHOCK, BE SURE ELECTRICITY IS TURNED OFF AT ELECTRICAL PANEL BOARD BEFORE WIRING. ALL WIRING MUST BE DONE IN ACCORDANCE WITH LOCAL CODES AND THE HEATER MUST BE GROUNDED AS A PRECAUTION AGAINST POSSIBLE ELECTRIC SHOCK. IN ABSENCE OF LOCAL CODES, FIELD WIRING TO THE UNIT SHALL COMPLY WITH CURRENT PROVISIONS OF THE AMERICAN NATIONAL ELECTRICAL CODE OR YOUR NATIONAL ELECTRICAL CODE, AS APPLICABLE. NOTE: Connect heater only to a line with the voltage and frequency specified on the nameplate. Branch Circuit Connections (Power) 1. Wiring compartment access door is hinged. To open, turn single screw on the side until the door swings away from the heater (See Figure ...

Ce manuel est également adapté pour les modèles :
électrique - CEH-003M (682.49 kb)
électrique - CEH-003MB (682.49 kb)
électrique - CEH-003P (682.49 kb)
électrique - CEH-003PB (682.49 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories