Log:
Évaluations - 3, GPA: 3.7 ( )

Instructions Cadet, Modèle BF-30-2

Fabricant : Cadet
Taille : 783.45 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


RATE SCREW NAT 1.60 MIN. RATE SCREW LP 1.00 25 P-214 MAIN BURNER ORIFICE (BF-10 NAT) USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. HOW TO ORDER REPAIR PARTS Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list. Be sure to give all this information. Unvented Heater Model Number Part Description Unvented Heater Serial Number Part Number Type of Gas (Propane or Natural) Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, IL 62220-2623 16943-5-0806 Page 15 Page 16 16943-5-0806 PARTS VIEW OPTIONAL BLOWER INSTALLATION INSTRUCTIONS SRB-18T and SRB-30T for Unvented Room Heaters BF-10, BF-20 and BF-30 INSTALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on SRS-18 or SRS-30 optional floor stand there is adequate access area available to install the optional blower. 1. Turn "OFF" gas supply to the heater. 2. Remove lower louver from casing assembly (2 screws). 3. Remove reflector from casing assembly (2 screws). 4. Remove upper louver from casing assembly (2 screws). 5. Insert the fan control wires and the upper portion of the fan control through the 3/4" (19mm) diameter hole on the bottom side of the top heat shield. The fan control wires will enter into the top portion of the heater and the fan control disc will be facing the main burner. Attach fan control to the bottom side of the top heat shield with (2) screws provided with the optional blower. 6. Route cord set through 9/16" (14mm) diameter hole on casing assembly back. Insert approximately 3" (76mm) of cord set into casing assembly back. 7. When you are facing the front of the heater, position the optional blower assembly onto the top heat shield of the heater. The motor wire harness should be facing into the top, right portion of the heater. 8. Attach (1) pin terminal from black (hot) wire, smooth insulation on cord set to (1) socket terminal on fan control wire harness. 9. Attach (1) pin terminal from black (neutral) wire, ribbed insulation on cord set to (1) socket terminal from white (neutral) wire on motor wire harness. 10. Attach (1) pin terminal on fan control wire harness to (1) socket terminal from black (hot) wire on motor wire harness. 11. Attach the green ground wire from the motor wire harness and the green ground wire from the cord set to the bottom right side of the blower housing with (1) screw provided with the optional blower. 12. With the heater standing upright, position the air discharge opening of the blower housing downward. Place the bottom flange of the blower housing over the top edge of the top heat shield. Insert the blower housing into the top portion of the heater by pivoting the blower housing upward 90°. Attach the blower housing to the casing assembly with (4) screws provided with the optional blower. 13. Grasp cord set at casing assembly back and pull excess cord set through casing assembly back. Secure cord set in casing assembly back with the strain relief provided with the optional blower. 14. Installation of optional blower SRB-18T or SRB-30T is completed. 15. If heater was removed from the wall, in order to install SRB-18T or SRB-30T optional blower, check for gas leaks at all gas connections before lower louver is replaced onto casing assembly. Attention! After optional blower has been installed use the following steps to properly align the upper louver and the reflector with the heat shield. A. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield. B. When replacing reflector, be sure the top lip of reflector goes in front of the heat shield. Excessive Blower Wheel Noise ATTENTION! Ifyourblowerassemblydevelopsasqueal,humorgrinding noise, it indicates dirt or debris on shaft of blower wheel. Use the following steps to clean shaft of blower wheel. 1. Remove red rubber grommet with brass bushing or black rubber grommetwith brass bushingfrom endof blower wheel shaftopposite motor. 2. Clean blower wheel shaft with cotton cloth. 3. Place 1 or 2 drops of all purpose oil on END of blower wheel shaft. 4. Replace red rubber grommet with brass bushing or black rubber grommetwithbrassbushingontoendofblowerwheelshaft.Attention: The red rubber grommet wi...

Ce manuel est également adapté pour les modèles :
électrique - BF-10-2 (783.45 kb)
électrique - BF-10-2 (783.45 kb)
électrique - BF-20-2 (783.45 kb)
électrique - BF-30-2 (783.45 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories