|
Facilité d'utilisation
Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. AUXILIARY LIMIT SWITCH For your safety this furnace is equipped with a manual reset auxiliary limit switch. In case of failure by the primary limit switch, this switch will shut the valve down completely before unsafe temperatures are reached. After a cool down period, switch must be manually reset. If outages persist, call a qualified service person. MAINTENANCE INSTRUCTIONS 1. Installation and repair must be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, pilot burners, circulating air passageways and venting systems of the appliance be kept clean. 2. The bearings of the motor should be oiled every six months with S.A.E. 20 oil. 3. The appliance area must be kept clear and free of any combustible materials, gasoline and other flammable vapors and liquids. 4. It is essential that the flow of combustion and ventilation air not be obstructed. 5. Periodic examination of the entire ventilation system as a routine part of the safety performance check is recommended on an annual basis. IMPORTANT: Keep burner and control compartment clean. Vacuum burner compartment at the start of the heating season or as often as needed. NOTE: It is advised that the burner flames be checked at least twice during the heating season for any changes in burner flame characteristics. 115 VAC 60 HZ – Less than 12 Amps. If any of the original wire as supplied with this appliance must be replaced, it must be replaced with type thermoplastic 105-degree C wire or its equivalent. Page 13 CF353C-H, CF354C-H Thermostat Power Cord STANDING PILOT CF503/504C-H, CF653/654C-H THERMOSTAT POWER CORD White WHITE Black GreenWhite WhiteBlack RED Black Motor Brown GREEN BLACK MOTOR BLACK RED Black BlackBlack Black Blue BROWN BLACK BLUE Transformer GREEN TRANSFORMER Black Blue BLACK BLUE Spill Brown SPILL RED BROWN SWITCH Switch Black Limit Fan LIMIT SELECTOR FAN Switch Switch SWITCH SWITCHSWITCH Auxiliary BLACK AUXILIARY Limit Switch LIMIT SWITCH TH CF353C-H, TH CF503C-H, CF504C-H TR CF354C-H TR CF653C-H, CF654C-H PICTORIAL PICTORIAL Gas Valve SCHEMATIC AMPS SCHEMATIC GAS VALVE AMPS 1.95 2.25 FAN SWITCHMOTOR FAN SWITCHSELECTOR SWITCH MOTOR LIMIT SWITCH THERMOSTATTRANSFORMER115 V.A.C. 24 V.A.C. CF353C-H CF354C-H LADDER SCHEMATIC LIMIT SWITCH THERMOSTATTRANSFORMER115 V.A.C. 24 V.A.C. CF503C-H, CF504C-H CF653C-H, CF654C-H LADDER SCHEMATIC SPILL AUXILIARY SPILL AUXILIARY SWITCH LIMIT SWITCHSWITCH LIMIT SWITCH GAS GAS VALVE VALVE Page 14 CF357C-H, CF358C-H I.I.D. CF557C-H, CF558C-H THERMOSTAT CF357C-H, CF358C-H THERMOSTAT CF557C-H, CF558C-HPICTORIAL PICTORIALPOWER SCHEMATIC POWER SCHEMATIC CORD CORD WHITE WHITE RED BLACK MOTOR GREEN BLACK GREEN BLACK MOTOR RED BLACK BROWN BLACK BLUE BROWN BLACK BLUE GREEN TRANSFORMER TRANSFORMER BLACK BLACK BLUE BLUE SPILL RED SPILL SWITCH BROWN SWITCHBROWN AUXILIARY LIMIT SWITCH LIMIT SWITCH FAN SWITCH AUXILIARY LIMIT SWITCH LIMIT SWITCH FAN SWITCH SELECTOR SWITCH BLACK PILOT PILOT PV MV/PV MV BLACK Spark BLACK GAS VALVE Spark GAS VALVE PV MV/PV MV Sense Sense 24 V 24 V Gnd. Gnd.(Burner) IGNITIONMODULE 24 V 24 V Gnd. Gnd.(Burner) PV MV/PV PV MV/PV MV MV MODEL NO. CF357C-H CF358C-H AMPS 2.2 2.25 FAN SWITCHMOTOR LIMIT SWITCH 115 V.A.C. TRANSFORMER 24 V.A.C. THERMOSTAT CF357C-H CF358C-H LADDER SCHEMATIC SPILL AUXILIARY SWITCHLIMIT SWITCH IGNITION MODULE GAS VALVE MODEL NO. AMPS CF557C-H 2.5 CF558C-H 2.55 SELECTOR SWITCH FAN SWITCH MOTOR LIMIT SWITCH 115 V.A.C. TRANSFORMER THERMOSTAT 24 V.A.C. CF557C-H CF558C-H LADDER SCHEMATIC SPILL AUXILIARY SWITCHLIMIT SWITCH IGNITION MODULE GAS VALVE Page 15 ROUGH-INS FOR REAR OR SIDE DISCHARGE Install plastergrounds as shown in Figure 12 and Figure 13. NOTE: When side discharge is being used, furnace should be set exactly 4” from side wall. Plaster Ground 14-11/16” 14-1/2” 1/2” REAR FIGURE 12 14-3/8” 10-3/ 16” Plaster Ground SIDE FIGURE 13 OPTIONAL ACCESSORY KITS REAR REGISTER KIT (Flush Mount) REAR DISCHARGE KIT (Recessed) (See Figure 14) 1. Use optional kit No. 406RR-A. 2. Cut openings in drywall as shown in Figure 12. 3. Position plasterground as shown in Figure 12 (Optional). 4. Cut out and remove embossed section on casing rear. 5. Remove knockout on inner liner. 6. Put heater into position. 7. Place inner boot into position, mark and cut boot flush with wall. Place damper into cutout end of inner boot, mark (4) holes from damper onto inner boot, top and bottom, and drill (4) 1/8” hole. Place outer boot into position, mark and cut boot flush with wall. 8. Attach inner boot to liner. Attach damper to inner boot (screws provided). Attach outer boot to casing back. 9. Place grill in position and secure to wall. 10. Final installation will appear as Fig...
Ce manuel est également adapté pour les modèles :électrique - CF354C-H (409.33 kb)
électrique - CF353C-H, CF503C-H, CF653C-H, CF354C-H, CF504C-H, CF654C-H, CF357C-H, CF557C-H, CF358C-H, CF558C-H (409.33 kb)
électrique - CF654C-H (409.33 kb)