Facilité d'utilisation
intake or exhaust pipe length. What is the altitude? 7 Furnace capacity? FIGURE 21 MINIMUM VENT PIPE LENGTHS IMPORTANT Do not use screens or perforated metal in exhaust or intake terminations. Doing so will cause freeze-ups and may block the terminations. *Any approved termination may be added to the minimum length listed. **This gas furnace must have 3” to 2” reducing ell (supplied or field replacement Canadian kit) installed directly into unit flue collar. TABLE 4 506724-01 Issue 1108 Page 17 of 57 A93UH and 92G1UH Maximum Allowable Intake or Exhaust Vent Length in Feet *Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe size. Standard Termination at Elevation 0 . 10,000 Number Of 90° Elbows Used 2" Pipe 2.1/2" Pipe 3" Pipe Model Model Model 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 76 61 39 19 n/a 110 95 63 38 n/a 132 132 113 113 109 2 71 56 34 14 105 90 58 33 127 127 108 108 104 3 66 51 29 9 100 85 53 28 122 122 103 103 99 4 61 46 24 n/a 95 80 48 23 117 117 98 98 94 5 56 41 19 90 75 43 18 112 112 93 93 89 6 51 36 14 85 70 38 13 107 107 88 88 84 7 46 31 9 80 65 33 8 102 102 83 83 79 8 41 26 n/a 75 60 28 n/a 97 97 78 78 74 9 36 21 70 55 23 92 92 73 73 69 10 31 16 65 50 18 87 87 68 68 64 Concentric Termination Elevation 0 . 10,000 Number Of 90° Elbows Used 2" Pipe 2.1/2" Pipe 3" Pipe Model Model Model 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 68 53 37 17 n/a 100 85 59 34 n/a 116 116 109 109 100 2 63 48 32 12 95 80 54 29 111 111 104 104 95 3 58 43 27 7 90 75 49 24 106 106 99 99 90 4 53 38 22 n/a 85 70 44 19 101 101 94 94 85 5 48 33 17 80 65 39 14 96 96 89 89 80 6 43 28 12 75 60 34 9 91 91 84 84 75 7 38 23 7 70 55 29 n/a 86 86 79 79 70 8 33 18 n/a 65 50 24 81 81 74 74 65 9 28 13 60 45 19 76 76 69 69 60 10 23 8 55 40 14 71 71 64 64 55 TABLE 5 Page 18 of 57 Issue 1108 506724-01 A95UH and 95G1UH Maximum Allowable Intake or Exhaust Vent Length in Feet *Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe size. Standard Termination at Elevation 0 . 4,500 Number Of 90° Elbows Used 2" Pipe 2.1/2" Pipe 3" Pipe Model Model Model 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 76 61 39 19 n/a 110 95 63 38 n/a 132 132 113 113 109 2 71 56 34 14 105 90 58 33 127 127 108 108 104 3 66 51 29 9 100 85 53 28 122 122 103 103 99 4 61 46 24 n/a 95 80 48 23 117 117 98 98 94 5 56 41 19 90 75 43 18 112 112 93 93 89 6 51 36 14 85 70 38 13 107 107 88 88 84 7 46 31 9 80 65 33 8 102 102 83 83 79 8 41 26 n/a 75 60 28 n/a 97 97 78 78 74 9 36 21 70 55 23 92 92 73 73 69 10 31 16 65 50 18 87 87 68 68 64 Standard Termination at Elevation 4,501 . 10,000 Number Of 90° Elbows Used 2" Pipe 2.1/2" Pipe 3" Pipe Model Model Model 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 76 61 39 n/a n/a 110 95 63 38 n/a 132 132 113 113 109 2 71 56 34 105 90 58 33 127 127 108 108 104 3 66 51 29 100 85 53 28 122 122 103 103 99 4 61 46 24 95 80 48 23 117 117 98 98 94 5 56 41 19 90 75 43 18 112 112 93 93 89 6 51 36 14 85 70 38 13 107 107 88 88 84 7 46 31 9 80 65 33 8 102 102 83 83 79 8 41 26 n/a 75 60 28 n/a 97 97 78 78 74 9 36 21 70 55 23 92 92 73 73 69 10 31 16 65 50 18 87 87 68 68 64 Concentric Termination Elevation 0 . 4,500 Number Of 90° Elbows Used 2" Pipe 2.1/2" Pipe 3" Pipe Model Model Model 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 68 53 37 17 n/a 100 85 59 34 n/a 116 116 109 109 100 2 63 48 32 12 95 80 54 29 111 111 104 104 95 3 58 43 27 7 90 75 49 24 106 106 99 99 90 4 53 38 22 n/a 85 70 44 19 101 101 94 94 85 5 48 33 17 80 65 39 14 96 96 89 89 80 6 43 28 12 75 60 34 9 91 91 84 84 75 7 38 23 7 70 55 29 n/a 86 86 79 79 70 8 33 18 n/a 65 50 24 81 81 74 74 65 9 28 13 60 45 19 76 76 69 69 60 10 23 8 55 40 14 71 71 64 64 55 Concentric Termination Elevation 4,501 . 10,000 Number Of 90° Elbows Used 2" Pipe 2.1/2" Pipe 3" Pipe Model Model Model 045 070 090 110 135 045 070 090 110 135 045 070 090 110 135 1 68 53 37 n/a n/a 100 85 59 34 n/a 116 116 109 109 100 2 63 48 32 95 80 54 29 111 111 104 104 95 3 58 43 27 90 75 49 24 106 106 99 99 90 4 53 38 22 85 70 44 19 101 101 94 94 85 5 48 33 17 80 65 39 14 96 96 89 89 80 6 43 28 12 75 60 34 9 91 91 84 84 75 7 38 23 7 70 55 29 n/a 86 86 79 79 70 8 33 18 n/a 65 50 24 81 81 74 74 65 9 28 13 60 45 19 76 76 69 69 60 10 23 8 55 40 14 71 71 64 64 55 TABLE 5 Continued 506724-01 Issue 1108 Page 19 of 57 Page 20 of 57 Issue 1108 506724-01 FIGURE 22 TYPICAL EXHAUST PIPE CONNECTIONS IN UPFLOW DIRECT OR NON.DIRECT VENT APPLICATIONS TRANSITION 2” 2” 2” 3” 2” 2” or Pipe size determined in table 5 DO NOT transition from smaller to larger pipe in horizontal runs of exhaust pipe. EXHAUST *2” * When transitioning up in pipe size, use the shortest length of 2” PVC pipe possible. NOTE . Exhaust pipe and intake pipe must be the same diameter. or FIGURE...
Ce manuel est également adapté pour les modèles :électrique - WARM AIR GAS FURNACE A93UH (3.02 mb)
électrique - WARM AIR GAS FURNACE 92G1UH (3.02 mb)
électrique - WARM AIR GAS FURNACE A95UH (3.02 mb)