4.Zone valve does not open. 5.Electrical problems (relay, wiring, fuse, low voltage, brown-outs, etc.) 6.BOILER MATE™ scale build-up. 7.Clogged filter (if used) or clogged strainer in steam boiler systems. 1.a.Press reset button on boiler. b.Check main cut-off switch. c. Check fuse. 2.a.Check power supply. b.Check shaft coupling. c.Check impeller for locking. 3.Set BOILER MATE™ temperature to a higher setting. Call boiler service. 4.Check power supply. 5.a.Check fuse and replace. b.Check circuit breaker and reset (if applicable). c.Check power supply. d.Low voltage or brown-out conditions can make the boiler control inoperative; engage the boiler reset button. 6.If boiler, circulator, and BOILER MATE™ temperature controls are operating satisfactorily, the BOILER MATE™ coil may have scale coating. Remove coil and clean or keep coil in tank and treat with a phosphoric acid product (e.g. NuCalgon - 1-800-554-5499) (Refer to page 20) 7.Clean and replace filter. 2. Insufficient or runs out of 1.BOILER MATE™ 1.Set BOILER MATE™ hot water at faucet. temperature setting too low. 2.Undersized boiler with no priority to domestic hot water. 3.Peak use of hot water is greater than BOILER MATE™ storage. 4.BOILER MATE™ scale build-up. 5.Faulty BOILER MATE™ temperature control. temperature control to a higher setting. 2.Rewire for priority. 3.Determine peak usage and compare tank volume. 4.Clean coil according to instructions. 5.Replace control. 3. Water at faucet too hot. 1.BOILER MATE™ temperature is set too high. 2.Improper system plumbing. 3.Improper system wiring. 4.Probe out of thermostat well. 1.Lower BOILER MATE™ temperature. 2.Compare plumbing to installation guide. 3.Compare wiring to installation guide. 4.Check to make sure Probe is properly inserted, see Figure 2 Page 8. 4. Boiler cycles more than 5 times per day in summer. Boiler runs for longer Periods of time . 1.Excessive demand. 2.Damaged or broken BOILER MATE™ temperature control. 3.Boiler hi-limit set too low. 4.BOILER MATE™ scale build-up. 1.Reduce demand or consider larger BOILER MATE™. 2.Replace BOILER MATE™ temperature control. 3.Increase boiler hi-limit. 4.Clean coil according to instructions. -13 9. SERVICE RECORD DATE SERVICE PERFORMED COMMENTS CONTRACTOR -14 AMTROL® BOILERMATE™ CLASSIC AND TOP-DOWN™ LIMITED PRODUCT WARRANTY AMTROL® BOILERMATE™ CLASSIC AND TOP-DOWN™ LIMITED PRODUCT WARRANTY This Warranty cannot be transferred - it is extended only to the original Purchaser or First User of the Product. By accepting and keeping this Product you agree to all of the warranty terms and limitations of liability described below. IMPORTANT WARNING: READ CAREFULLY THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL (“MANUAL”) to avoid serious personal injury and/or property damage and to ensure safe use and proper care of this product. Mail Your Product Registration Card Within 30 Days of Purchase to Ensure Your Warranty Coverage or Proof of Purchase Will Be Required for All Warranty Claims. LIMITED LIFETIME WARRANTY* Tank Assembly and Heat Exchanger (To Original Product Owner, Single Family Residence) WH and TD Model Numbers Covered: WH-7Z, WH7-ZDW, WH7-P, WH7-L, WH7-LDW, WH-9L, WH-9LDW, TD-7L, TD-7Z,TD-7P, TD-7LDW, TD-7ZDW LIMITED FIVE YEAR COMMERCIAL WARRANTY** Model Numbers Covered: WH7C, WH7CDW LIMITED FIVE YEAR TRANSFERRABLE WARRANTY** Model Numbers Covered: WH-41Z, WH-41L, TD-41L, TD-41Z, TD-41LDW and TD-41ZDW only Warranty for these models only runs from date of manufacture and are transferable *FOR AS LONG AS YOU OWN AND LIVE IN YOUR SINGLE FAMILY HOME, this Warranty covers the tank assembly and heat exchanger, if you are the first user or original owner of this BoilerMate™ Classic and Top-Down™ and purchased it for single family home use – subject to all of the conditions, limitations and exclusions listed below. Purchasers who buy the BoilerMate™ Classic and Top-Down™ for other purposes, and other component parts are subject to more limited warranties and you should read all of the terms included in this form to make sure you understand your Warranty. LIMITED WARRANTY ON BOILERMATE™ CLASSIC AND TOP-DOWN™ TANK ASSEMBLY AND HEAT EXCHANGER AMTROL Inc. (“AMTROL”) warrants that at the time of manufacture, the BoilerMate™ Classic and Top-Down™ heat exchanger and tank assembly shall be free from defects in material and workmanship for one of two time periods as follows: Period 1 – Single Home Use. If you are the first user or original owner of the BoilerMate™, for as long as you own and occupy the single-family home in which the BoilerMate™ Classic and Top-Down™ has been properly installed. Period 2 - ** Commercial and Other Uses. For five years from the date of purchase if you are the first user or original owner first using the new BoilerMate™ Classic and Top-Down™ (except for the model numbers listed above that are transferable), and you are not a homeowner-purchaser as described in Period 1 (for example, if you purchased the Product fo...

Ce manuel est également adapté pour les modèles :
électrique - TD-41Z (317.69 kb)
électrique - TD-41Z (317.69 kb)
électrique - TD-41ZDW (317.69 kb)
électrique - TD-7Z (317.69 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories