Log:
Évaluations - 4, GPA: 3.8 ( )

Instructions State Industries, Modèle Gas

Fabricant : State Industries
Taille : 145.47 kb
Nom Fichier : d001ebb4-2df0-4b4c-80d7-a91a5e20a544.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


– NOTE: This Outline Is NOT A Warranty. For complete information, consult the written warranty or State Water Heaters. ¦ TPO – Oil Fired Models: No. 1 or 2 Oil – Multi-annular fuel containment combustor head – Available for firing light fuel oils including diesel – Oil ignition transformer – Integral 2-stage fuel unit – Squirrel cage blower – Oil safety valve ¦ TPD – Dual Fuel Gas/Oil: Natural Gas or Propane & No. 1 or 2 Oil – Multi-annular fuel containment combustor head – Gas electric pilot and gas ignition transformer – Pilot and main pressure regulators – Air safety switch – Manual fuel selector switch – Integral 2-stage fuel unit – Squirrel cage blower ¦ Meets or exceeds current edition of ASHRAE/IES-90.1-1999. ¦ Low NOX – TPX Low NOX models meet or exceed current Texas and California SCAQMD air quality standards. ¦ UL – Entire unit UL listed (File No. MH11631). ¦ Glass-Lined Tank – Exclusive corrosion protection with glass- lining on all interior surfaces. Multiple anodes provide even more corrosion protection. ¦ ASME Construction Standard – 160 PSI working pressure on all models. ¦ Powered Gas Burner – Powered burner has electronic flame safeguard control with intermittent spark ignition. Also included are main and pilot automatic gas valves plus gas pressure regulators, diaphragm air switch for proof of blower operation. – TPX Low NOX Models are factory standard with modulating fire. The burner automatically adjusts the firing rate and the Btu output to maintain precise system temperature control. ¦ Fully Automatic Controls With Safety Shutoff – High temperature limit control (manual reset). ASME rated temperature and pressure relief valve. Hinged door control compartment for ease of access. Two thermostats, upper and lower, for accurate temperature control. Standard control is for 120°F - 180°F water service. ¦ Jacket And Insulation – Heavy gauge steel with baked powder coat finish. Insulated with high-density foam insulation that meets or exceeds all required standards. ¦ Professional Start-Up Service Furnished To Assure Most Efficient Combustion And Safe Initial Start-Up. ¦ Other Features – Two layers of high temperature ceramic fiber insulation in combustion chamber – Flame inspection port opening – Mounted on rugged channel iron skids – Combination temperature and pressure gauge – Low water cutoff – ASME rated temperature and pressure relief valve – Barometric draft regulator – Two cleanout inspection openings – 120 volt control circuit – Drain valve – Removable lifting lugs ¦ Options – Factory Mutual approved control arrangement – Industrial Risk Insurance (IRI Gas Train) – 5 year or 10 year limited warranty – High or low water pressure switch – 180°F water service thermostats – A.G.A. rated T & P Valve – Modular graphic burner systems management on heaters with 270,000 Btu input and over – Combustion Air intake Adapter COMMERCIAL 500 Lindahl Parkway, Ashland City, TN 37015 • The Expert’s Choice® TPG Power Gas Large Volume Commercial Water Heaters SPECIFICATIONS Nominal Input Output (Gallons) Storage Rating Ship. Model Number Capacity BTU/Hr. First Recovery Dimensions In Inches Wt. Motor HP U.S. Natural Hour w/Burner 120V 60 Hz 1 Gallons Gas Rating 80°F Rise 100°F Rise 140°F Rise A B C D E F G H J (lbs.) TPG 150 140 NEA 150 140,000 256 170 136 97 831.2 14 1.2 273.4 11.4 361.2 5 47 73 1292 TPG 150 199 NEA 150 199,000 313 241 193 138 831.2 14 1.2 273.4 11.4 361.2 6 47 73 1292 1.7 HP - 2.5 Amps TPG 150 255 NEA 150 255,000 367 359 247 176 831.2 14 1.2 273.4 11.4 361.2 6 47 73 1292 TPG 150 270 NEA 150 270,000 382 327 262 187 831.2 14 1 273.4 11.4 361.2 6 571.2 73 1397 TPG 150 400 NEA 150 400,000 507 485 387 277 831.2 14 1 273.4 11.4 361.2 7 571.2 73 1397 1.4 HP - 4.6 Amps TPG 150 540 NEA 150 540,000 644 654 524 374 831.2 14 1 273.4 11.4 361.2 8 571.2 73 1505 TPG 150 720 NEA 150 720,000 818 873 698 499 831.2 14 11.4 273.4 11.4 361.2 10 571.2 73 1510 1.3 HP - 5.5 Amps TPG 200 300 NEA 200 300,000 451 364 291 208 831.2 15 1 321.2 11.2 443.4 6 661.2 73 2098 1.4 HP - 4.6 Amps TPG 200 600 NEA 200 600,000 742 727 582 416 831.2 15 1 321.2 11.2 443.4 8 661.2 73 2098 TPG 200 800 NEA 200 800,000 936 970 776 554 831.2 15 11.4 321.2 11.2 443.4 10 661.2 73 2103 1.3 HP - 5.5 Amps TPG 200 1000 NEA 200 1,000,000 1130 1212 970 693 831.2 15 11.4 321.2 11.2 443.4 10 661.2 73 2103 TPG 200 1250 NEA 200 1,250,000 1372 1515 1212 866 831.2 15 11.4 321.2 11.2 443.4 12 661.2 73 2467 1.2 HP - 7.4 Amps TPG 200 1500 NEA 200 1,500,000 1615 1818 1455 1039 831.2 15 11.2 321.2 11.2 443.4 12 811.2 73 2757 TPG 300 300 NEA 300 300,000 531 364 291 208 911.2 14 1 261.2 11.2 443.4 6 661.2 83 2150 1.4 HP - 4.6 Amps TPG 300 600 NEA 300 600,000 822 727 582 416 911.2 14 1 261.2 11.2 443.4 8 661.2 83 2150 TPG 300 800 NEA 300 800,000 1016 970 776 554 911.2 14 11.4 261.2 11.2 443.4 10 661.2 83 2308 1.3 HP - 5.5 Amps TPG 300 1000 NEA 300 1,000,000 1210 1212 970 693 911.2 14 11.4 261.2 11.2 443.4 10 661.2 83 2308 TPG 300 ...

Ce manuel est également adapté pour les modèles :
électrique - Oil & Dual Fuel Commercial Water Heaters (145.47 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories