|
Instructions Watlow Electric, Modèle Rapid Response Electric Heat Exchanger
Fabricant : Watlow Electric Taille : 123.73 kb Nom Fichier : e9795375-fb36-4f33-a8b7-a719037053e2.pdf
Langue d'enseignement:
|
|
|
|
Aller à la télécharger
Facilité d'utilisation
Add to this the value of high pressure operating capabilities in custom formations and integrated sensing with Watlow sensors and controllers and you will quickly see the advantages of using the RAPID RESPONSE Heat Exchanger. This patent-pending product was developed around Watlow’s high quality WATROD electric heating element placed inside of a tube designed to specifically accommodate your process pressure and temperature. A wide range of special fittings on the ends of the outer tube facilitates transition of both the fluid and WATROD electrical terminations. The intimate contact of the WATROD element with your fluid and the low thermal mass of the overall system result in high-energy efficiency and fast response. If needed, appropriate molded insulation packages can be added for efficiency improvements or touch-safe protection. The design of this product tends to enhance the circulation of your gas or fluid because of the excellent convective film coefficients created, even at lower flow rates. If your application demands precise temperature control, let the RAPID RESPONSE Heat Exchanger provide the thermal response, wattage and space savings you need. High operating pressure will not be an issue. Add integrated sensing with Watlow sensors and controllers and you will have a complete thermal solution. Applications • Solvent replacement • Gas heating • Fuel cell gas heating • Supercritical fluids • Parts cleaning • Humidity generation • Biomass extraction • Bio reclamation • Refrigeration systems • Aerospace, food and • Epoxy resin deionized water heating components Patent Number: U.S. 6,944,394 B2 Incoloy® is a registered trademark of the Special Metals Corporation. Features and Benefits Compact size and lightweight design • Reduces the physical space required by other circulation heater technologies substantially Fast thermal response • Allows low flow conditions to be efficiently heated High and low working pressure availability • Provides a wide range of operating pressures Low internal volume • Increases heater efficiency significantly • Minimizes overall system volumetric impact Use with gases and liquids • Assures effectiveness in all media states Specifications • Up to 30 amps in compact configurations • Process temperatures up to 600°C (1200°F) • Operating pressure up to 411 bar (6000 psi) • Standard 208 Volt (120-480 Volt 1-phase and 3-phase capability) • Optional finishes include: electro polished, bright annealed, passivated • Integral inlet/outlet RTD or thermocouple sensors • Standard 0.25 in. (6.35 mm) NPT low pressure fitting (standard and specialized process fittings are available and chosen by pressure and formation) • Materials of construction – 304 and 316L Stainless Steel, Incoloy®, Copper • Outside tube diameters: 0.5 and 0.625 in. (13 and 16 mm) • Trim length and electrical terminations consistent with typical WATROD options • Bend radii – 0.625 in. (16 mm) for flat bends, 2 in.(51 mm) inside diameter for coiled bends • Insulation materials available – foam rubber, castable ceramic and fiberglass HAN-RRHE-0807 RAPID RESPONSE Heat Exchanger High Limit Sensor WATROD Heating Element Female Process Fluid Connection Heater/Process Fluid Transition WATROD Electrical Connection Inline Process Sensor Male Process Fluid Connection WATROD Electrical Connection Exchanger Outer Wall *This drawing is intended for illustrative purposes only and is not intended to depict a specific RRHE design. RAPID RESPONSE Heat Exchanger High Limit Sensor WATROD Heating Element Female Process Fluid Connection Heater/Process Fluid Transition WATROD Electrical Connection Inline Process Sensor Male Process Fluid Connection WATROD Electrical Connection Exchanger Outer Wall *This drawing is intended for illustrative purposes only and is not intended to depict a specific RRHE design. Heat Exchanger and Circulation Heater Performance Comparison RAPID RESPONSE Heat Exchanger Tubular Type Circulation Heater Aluminum Block Circulation Heater Heat Exchanger 5 in. tall x 6 in. dia. (127 mm tall x 152.4 mm dia.) 25 in. tall x 4 in. dia. (635 mm tall x 101.6 mm dia.) 13.5 in. tall x 4 in. dia. (342.9 mm tall x 101.6 mm dia.) Ambient to 32°C (90°F) 10 seconds 30 seconds 371 seconds RAPID RESPONSEResponse time from ambient to 32°C (90°F) at 9.3 W/cm2 (60 W/in2) 3 liters per min. (0.8 gallons per min.) To be automatically connected to the nearest North American Technical and Sales Office: 1-800-WATLOW2 • • info@watlow.com International Technical and Sales Offices: Australia, +61-3-9335-6449 • China, +86-21-3950-9510 • France, +33 (0) 3073-2425 • Germany, +49 (0) 7253-9400-0 • Italy, +39 (0) 2 458-8841 • Japan, +81-3-3518-6630 • Korea, +82-2-575-9804 • Malaysia, +60-3-7980-7741 • Mexico, +52 (442) 217-6235 • Shanghai, +86-21-3950-9504 • Singapore, +65-6773-9469 • Spain, +34 91 675 1292 • Sweden, +46 35-27-11-66 • Taiwan, +886-7-288-5168 • United Kingdom, +44 (0) 115-964-0777 © 2007 Watlow Electric Manufacturing C...
Écrivez votre propre critique du dispositif
|
|