|
Facilité d'utilisation
That’s why we made daily service quick and easy. Look what’s behind those big, easy-to-open service doors. Checking filters and fluid levels has never been faster. We’ve even extended some routine service intervals, such as the engine oil-change interval. It’s been doubled from 250 to 500 hours. We simply want you to get to the job you love. (Mom would be so proud!) 8-9 The first hydraulic filter-change interval is not until 4,000 hours, then every 2,000 hours after that. That’s time and money better spent elsewhere. John Deere’s Customer Personal Service (CPS) features a line-up of programs and tools that can be customized to fit your business. Whether it’s maintenance programs, extended warranties, or parts availability programs, CPS is a one-on-one service that can bring uptime to an all-new level. Talk to your dealer about CPS today. We stand behind these new excavators. Want proof? Check out our StructurAll™ warranty. It adds three years of coverage on major structures as installed at the time your excavator is manufactured. It’s free of charge, for unlimited hours, on important stuff like booms, arms, and mainframes. Get to the point(s)! Servicing the cooling system is a snap. The cooling cores We don’t think there’s ever been a job site where feature wide-fin spacing so that trash will pass through there’s never mud, rain, or snow. That’s why we the system without clogging it, reducing cleaning time. strategically fastened bolt-on skid plates where you step or stand during routine service. SPECIFICATIONSEXCAVATORS 200C LC 230C LC 270C LC Engine 200C LC 230C LC 270C LC Type ......................................................................John Deere 6068H with turbocharger and air-John Deere 6068H with turbocharger and air-John Deere 6068H with turbocharger and air- to-air charge air cooler; meets EPA Tier II non-to-air charge air cooler; meets EPA Tier II non-to-air charge air cooler; meets EPA Tier II non- road emissions regulations road emissions regulations road emissions regulations Rated power ..........................................................141 SAE net hp (105 kW) @ 2,150 rpm 169 SAE net hp (126 kW) @ 2,100 rpm 177 SAE net hp (132 kW) @ 2,150 rpm Cylinders ...............................................................6 6 6 Displacement.........................................................414 cu. in. (6.8 L) 414 cu. in. (6.8 L) 414 cu. in. (6.8 L) Maximum net torque .............................................427 lb.-ft. (579 Nm) @ 1,300 rpm 516 lb.-ft. (700 Nm) @ 1,400 rpm 540 lb.-ft. (733 Nm) @ 1,400 rpm Fuel consumption, typical ......................................4.0 to 6.0 gal./hr. (15.1 to 22.7 L/h) 5.0 to 7.5 gal./hr. (19.0 to 28.0 L/h) 5.5 to 8.5 gal./hr. (21.0 to 32.0 L/h) Cooling fan ............................................................suction-type drive suction-type drive suction-type drive Electrical system ...................................................24 volt with 45-amp alternator 24 volt with 45-amp alternator 24 volt with 45-amp alternator Batteries (two 12 volt)............................................reserve capacity: 180 min. reserve capacity: 180 min. reserve capacity: 180 min. Off-level capacity...................................................100% (45 deg.) 100% (45 deg.) 100% (45 deg.) Hydraulic System Main pumps ..........................................................two variable-displacement axial-piston two variable-displacement axial-piston two variable-displacement axial-piston Minimum flow.................................................2 x 21.5 gpm (2 x 82 L/min.) 2 x 32.0 gpm (2 x 121 L/min.) 2 x 34.9 gpm (2 x 132 L/min.) Maximum flow................................................2 x 57.9 gpm (2 x 219 L/min.) 2 x 56.5 gpm (2 x 214 L/min.) 2 x 57.9 gpm (2 x 219 L/min.) Pilot pump .............................................................one gear one gear one gear Maximum flow................................................9.5 gpm (36 L/min.) 8.9 gpm (34 L/min.) 9.5 gpm (36 L/min.) Pressure setting..............................................580 psi (3999 kPa) 580 psi (3999 kPa) 580 psi (3999 kPa) System operating pressure Implement circuits ..........................................4,980 psi (34 336 kPa) 4,980 psi (34 336 kPa) 4,980 psi (34 336 kPa) Travel circuits .................................................4,980 psi (34 336 kPa) 4,980 psi (34 336 kPa) 5,050 psi (34 819 kPa) Swing circuits.................................................4,480 psi (30 888 kPa) 4,270 psi (29 441 kPa) 4,380 psi (30 199 kPa) Power boost....................................................5,270 psi (36 336 kPa) 5,270 psi (36 336 kPa) 5,270 psi (36 336 kPa) Oil filtration............................................................one 10-micron full-flow return filter with by-one 10-micron full-flow return filter with by-one 10-micron full-flow return filter with by- pass / one pilot oil filter pass / one pilot oil filter / one suction filter...
Ce manuel est également adapté pour les modèles :Loader - 200CLC (749.64 kb)
Loader - 270CLC (749.64 kb)